CS Paper Radar

Predicting Radiologist Expertise from 3D Gaze Patterns During CT Interpretation

Leila Khaertdinova, Anna Anikina, Claudia Mello-Thoms, Bulat Ibragimov

cs.CV cs.AIcs.LG ·submitted 2026-08-24 21:24 UTC · v1
top venuecode/data

Abstract

Accurate interpretation of volumetric CT requires efficient navigation of 3D image volumes and attention to diagnostically relevant regions. While eye-tracking has been widely studied in 2D medical imaging, its use for expertise assessment in CT settings remains limited. We propose a gaze-informed transformer framework for expertise classification in thoracic CT. Using a DINOv2 backbone, radiologist fixation patterns are integrated into volumetric feature learning through (1) a learnable log-space bias in self-attention and (2) gaze-weighted pooling of patch embeddings. We trained and evaluated our approach on 182 CT reading sessions from five radiologists with varying levels of experience. On a held-out test set, the model achieves an ROC-AUC of 0.91 and F1 score of 0.86, outperforming adapted methods. These findings suggest that incorporating visual search behavior into transformers may support objective, process-based expertise assessment in radiology. Code is available via https://github.com/leiluk1/GazeToSkill.

Comment
Accepted at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

RadAI: Gaze-Intention Fusion Pipeline for Attention-Guided Educational Videos in Chest X-Ray Interpretation

cs.CV ·2026-10-24 ·Kavish Mehta, Yuvan Siddharth Katamaneni, Akash Awasthi
publishedhot direction similarity 0.73
Abstract · 5 pages, 2 figures, 1 table, accepted to 2026 MIT IEEE URTC conference

Chest radiograph interpretation errors often arise from failures in visual search: although trainees may correctly identify an abnormality once pointed out, they frequently fail to fixate on the relevant region, while expert search strategies (where radiologists look, in what sequence, and for how long) remain largely implicit. Eye movement modeling examples (EMME), which replay a recorded expert's gaze over the image, have been shown to improve novice detection of findings on chest radiographs, but producing one requires an eye-tracking session on that specific case, so teaching sets are limited to recorded sessions by experts. In this work, RadAI is presented, the first end-to-end framework for transforming predicted radiologist gaze into narrated instructional videos, enabling scalable gaze-guided training without collecting new eye-tracking data. Given only a chest X-ray and its report, RadAI predicts an expert fixation sequence, associates each interval of that sequence with the diagnostic finding it pursues, extracts the corresponding image region, and renders the result as an EMME-style video in which each highlighted finding is narrated with synthesized speech. RadAI is evaluated on 97 cases from the EGD-CXR dataset, assessing whether the highlighted regions correspond to annotated abnormality locations. We position this work as a framework for scalable generation of educational content for residents and medical students in the field of radiology.

0.34

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

cs.CV ·2026-10-19 ·Michael Glöckler, Timo Ropinski
publishedcode/data similarity 0.70
Abstract · Accepted at WACV 2027. 24 pages, including references and supplementary material. Code and checkpoint: https://github.com/michaelgloeckler/X…

Vision-language models (VLMs) achieve remarkable performance on 2D medical images, such as X-rays or pathology images, while 3D VLMs that directly process CT/MRI volumes lag behind due to limited 3D training data and the predominance of 2D foundation architectures. To leverage powerful 2D VLMs for analyzing medical volumes, which contain hundreds of slices, it is therefore necessary to focus only on those few slices, which are diagnostically relevant. To enable such a prioritization, we propose XGLASS, a method that transfers medical expertise from 2D X-rays to 3D CT for task-aware slice prioritization. XGLASS uses disease-conditioned importance maps derived from language-aligned radiologist gaze on X-rays and spatially aligns them with coronal CT projections, bringing gaze priors and CT content into a shared 2D representation. The fused gaze-prior/CT projection is then used to predict a disease-specific ordering of axial slices, prioritizing diagnostically relevant slices. XGLASS significantly improves budgeted retrieval over 2D and 3D-native baselines, achieving a top-10 hit rate up to 75.9% for the best-performing disease. In practice, this means that after inspecting only the top 10 slices (4.17% of a 240-slice scan), XGLASS identifies a diagnostically relevant slice in more than 75% of cases. For downstream slice-wise finding classification, an XGLASS-selected 30-slice candidate set reduces model calls by 87.5% while improving F1 by 11.3 percentage points over all-slice inference, 4.2 points over the strongest 2D selector, and remains competitive with 3D-native selectors while requiring up to 130.8 times less time and 10.9 times less GPU memory per finding, supporting its use as a lightweight preselector for volumetric CT analysis. The code and pretrained checkpoint are available on https://github.com/michaelgloeckler/XGLASS.

0.48

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

cs.CV cs.HCeess.IVeess.SP ·2026-10-30 ·Nattakorn Kittisut, Roy M. Gabriel, Marly van Assen, Mohammadreza Zandehshahvar, Carlo N. De Cecco +2 more
similarity 0.69
Abstract · 20 pages on main manuscripts (3 tables + 4 figures), 14 pages supplementary (10 tables + 8 figures)

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

0.17

NV-Reason-CT: 3D Visual Language Model for CT Analysis

cs.CV cs.AI ·2026-09-23 ·Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon +13 more
highly cited similarity 0.68
Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

0.41

GazeRefine: Expert Gaze as a Test-Time Prompt for Training-Free Medical Image Segmentation

eess.IV cs.AIcs.CVcs.HC+1 ·2026-09-01 ·Mohammed Oussama Benyahia, Marouane Tliba, Mohamed Amine Kerkouri, Taifour Yousra, Bin Wang +8 more
publishedcode/data similarity 0.65
Abstract · 9 pages, 5 figures. Accepted at MICCAI Workshop 2026

Medical image segmentation remains difficult to scale because high-performing methods typically rely on dense expert annotations and task-specific training. We introduce GazeRefine, a training-free framework that uses gaze as an inference-time prompt for zero-shot medical image segmentation. Sparse, duration-weighted fixations are converted into foreground and background priors that initialize semantic prototypes in frozen DINOv3 feature space. These prototypes are iteratively refined through foreground-background discrimination, feature-space affinity propagation, and anchoring to the initial gaze guidance, allowing segmentation to extend beyond directly fixated regions while limiting semantic drift. GazeRefine requires no segmentation masks, fine-tuning, adapters, prompt encoders, or gradient updates. We evaluate the method on gaze-annotated polyp segmentation and prostate MRI segmentation. The results show strong performance on colonoscopy images and competitive performance on prostate MRI, supporting gaze-guided prototype refinement as a promising approach for segmentation-label-efficient, human-in-the-loop medical image segmentation. Our tools and code can be found in the following repository: https://github.com/MohammedOussamaBEN/GazeRefine.git

0.73

Uni-Loc: Weakly Supervised 3D CT Pathology Localization via Spatially Grounded Vision-Language Classification

cs.CV ·2026-11-09 ·Hao-Chih Lee, Zahi A. Fayad, Xueyan Mei
similarity 0.65
Abstract

Accurate localization of abnormalities in three-dimensional (3D) CT scans is essential for linking automated predictions with clinically relevant pathological findings. We propose Uni-Loc, a vision-language framework that unifies pathology classification and 3D localization using scan-level supervision. Uni-Loc derives both predictions and localization maps from spatial similarities between pathology-conditioned queries and image features. A token-to-voxel upsampling module enables high-resolution localization, while gradient-guided thresholding identifies pathology regions without additional learned parameters. Evaluated on five localization tasks comprising 355 annotated CT scans, Uni-Loc achieves macro-averaged voxel-level AUROC/AUPR of 96.1\%/34.5\%, outperforming relevance propagation (80.7%/13.9%) and gradient saliency (88.7%/8.1%). Uni-Loc also achieves classification AUROC of 88.39% on CT-RATE and 78.03% on RAD-ChestCT, improving over a matched baseline. These results demonstrate effective 3D pathology localization without requiring pathology-specific voxel-level supervision.

0.12

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.65
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.29

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.64
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41