CS Paper Radar

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens, Zirong Chen, Jiayu Wang, Xi Ouyang, Mingyang Yu, Weiqiu Jin, Xiaodan Ye, Dijia Wu, Kwang-Hyun Uhm, Inhwa Son, Rachel van 't Hull, Tim Veenboer, Cees Snoek, Kevin Groot Lipman, Daesung Kim, Junha Im, Youngjun Jun, Sangwon Lee, Katelyn Morrison, Adam Perer, Mijin Yun, Ali Piracha, Reem Alwasiah, Talal Yahyan, Abdulrahman Alamoudi, Mashael Alshehri, Rayan Alsager, Hannah Hancock, Anna M. Hunkemöller, Peter Youssef, Mona A. Alhammad, Afnan Aljumayan, Brecht Van Berkel, Eric Bijnens, Saud Alhussain, Maarten Steyvers, Rolf Symons, Bryan Eelen, Ayed Alaklubi, Maha Buraykan Alshammari, Amirah Fahad Alshammeri, Tomas Gilvydis, Ibrahim AlTurki, Monerah Almohideb, Ali Alburkani, Shahad Alhomaiani, Fatima Jabali, Maximilian Rokuss, Moritz Langenberg, Yannick Kirchhoff, Benjamin Hamm, Klaus Maier-Hein, Ibrahim Ethem Hamamci, Sezgin Er, Michael Moritz, Hassan R. Alomaish, Luyang Luo, Pranav Rajpurkar

cs.CV cs.AI ·submitted 2026-11-18 05:09 UTC · v1
benchmark

Abstract

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

Comment
25 pages, 13 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

EviGround-CT: Sentence-to-Volume Grounding for Verifying LLM-Generated Chest CT Reports

cs.CL cs.CVcs.LG ·2026-10-15 ·Ziyuan Li, Juncheng Ni, Feng Li
published similarity 0.70
Abstract · Accepted at IEEE BIBM 2026

Chest computed tomography (CT) reports generated by large language models (LLMs) can describe positive findings that lack localized evidence in the scan. We propose EviGround-CT to verify these findings after report generation. A deterministic extractor identifies positive finding sentences, and a 3D grounding model predicts an evidence mask for each sentence. Using the full sentence retains anatomical location, laterality, and descriptive modifiers in the grounding query. We evaluate report generation on CT-RATE, and grounding and verification on a held-out 100-case ReXGroundingCT subset. Using the available annotations, sentence-grounded verification raises evidence-supported precision (ESP) from 0.263 to 0.365 across 137 extracted in-scope positives, compared with category conditioning. The corresponding unsupported positive finding rate falls from 0.737 to 0.635. The paired case-level bootstrap ESP difference is +0.102 (95% confidence interval: [0.028, 0.181]). The predicted masks associate individual report statements with spatial evidence that can be inspected alongside the CT.

0.23

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.69
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.16

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

cs.CV cs.AI ·2026-08-28 ·Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, Şeyda Ertekin
publishedcode/data similarity 0.68
Abstract · Accepted to the Thoracic Image Analysis (TIA) Workshop at MICCAI 2026

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

0.62

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

cs.LG cs.HC ·2026-09-24 ·Nathan Le, Magdalini Paschali, Arogya Koirala, Andrew Johnston, Zhongnan Fang +3 more
publishedcode/data similarity 0.67
Abstract · 11 pages, 3 figures, 1 table. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imagin…

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as MC Dropout and Deep Ensembles, require access to model parameters or retraining. However, proprietary clinical AI systems operate as black boxes, preventing access to the model's internals. To that end, we propose a model-agnostic framework for improving calibration of black-box models using clinically grounded test-time augmentation (TTA). Our framework applies geometric and physics-inspired 3D CT perturbations and learns probability-level aggregation strategies without access to model internals or the original training data. Across pulmonary embolism and intracranial hemorrhage detection tasks, DualTTA achieved the strongest overall calibration among TTA methods, reducing the Expected Calibration Error by 54% (0.239 -> 0.109) and 43% (0.051 -> 0.029), respectively, while requiring only input-output access. Additionally, DualTTA outperformed uncertainty estimation techniques that require access to model internals, such as Temperature Scaling, MC Dropout, and Deep Ensembles, in most calibration metrics. These results demonstrate that learned TTA aggregation can improve the calibration of clinical AI systems, providing a practical approach for improving the reliability of black-box medical AI.

0.45

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.66
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

Rethinking weakly supervised localization on chest radiographs: position nulls, protocol dependence, and PACE

cs.CV cs.LG ·2026-09-29 ·Shixin Qiu
benchmark similarity 0.66
Abstract

Weakly supervised localization on chest radiographs is reported as a single overlap accuracy, and those numbers are not comparable across papers. We measure what one contains. Against position-null controls that keep a readout's own box and move only its position, class activation mapping and its gradient-weighted variant beat the null on two to four of seven annotated findings on ChestX-ray14 and two of eight on CheXlocalize. The null is beatable: three board-certified radiologists clear it on four to seven. Three rarely stated choices each move a result by more than most reported method effects: the results regime, the extraction threshold, and the mask-to-box rule, whose cost is predicted by how fragmented the thresholded mask is. Predicted box area alone reverses a paired comparison. These measurements produced PACE, for \emph{population anomaly and class evidence}, which multiplies the finding identity from the label-trained head by the spatial evidence from a frozen radiograph backbone that never sees a pathology label. It is the case study that made the protocol dependence visible, and we report its costs beside its gain: in an exploratory matched-area analysis it improves strict-overlap accuracy on both corpora and beats a label-derived second map, but it is the least faithful of the three readouts to the classifier's causal map, its advantage depends on the box rule, and, this benchmark releasing no localization validation set, every design choice behind it was made on the boxes it is scored on. Its one clean transfer beats one baseline and loses to the other.

0.27

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.65
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.65
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.31