CS Paper Radar

EviGround-CT: Sentence-to-Volume Grounding for Verifying LLM-Generated Chest CT Reports

Ziyuan Li, Juncheng Ni, Feng Li

cs.CL cs.CVcs.LG ·submitted 2026-10-15 09:14 UTC · v1
published

Abstract

Chest computed tomography (CT) reports generated by large language models (LLMs) can describe positive findings that lack localized evidence in the scan. We propose EviGround-CT to verify these findings after report generation. A deterministic extractor identifies positive finding sentences, and a 3D grounding model predicts an evidence mask for each sentence. Using the full sentence retains anatomical location, laterality, and descriptive modifiers in the grounding query. We evaluate report generation on CT-RATE, and grounding and verification on a held-out 100-case ReXGroundingCT subset. Using the available annotations, sentence-grounded verification raises evidence-supported precision (ESP) from 0.263 to 0.365 across 137 extracted in-scope positives, compared with category conditioning. The corresponding unsupported positive finding rate falls from 0.737 to 0.635. The paired case-level bootstrap ESP difference is +0.102 (95% confidence interval: [0.028, 0.181]). The predicted masks associate individual report statements with spatial evidence that can be inspected alongside the CT.

Comment
Accepted at IEEE BIBM 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.70
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.32

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.67
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.66
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

Scaling 3D Visual Grounding in Abdominal CT

cs.CV cs.LG ·2026-10-02 ·Sam Church, Danyal Maqbool, Joshua D. Warner, Andrew Voter, Junjie Hu +2 more
similarity 0.66
Abstract

Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.

0.08

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

cs.LG cs.AI ·2026-08-30 ·Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan +1 more
benchmark similarity 0.65
Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

0.25

Clinical Reasoning Under a Partially Observed Objective in Cone Beam CT Report Generation

cs.CL cs.CV ·2026-09-02 ·Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
code/data similarity 0.64
Abstract · 11 pages, 3 figures. ODIN 2026 CBCT report generation challenge system. Code: https://github.com/GIND123/CBCT-Clinical-Reasoner

Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large language model judgement of factual entailment and 20% on lexical overlap, of which only the lexical fifth is visible during development. The grader's BLEU-4 and METEOR routines are reproduced in pure Python and match the reference to machine precision, and an offline entailment surrogate, which tells a report written for one patient from one written for another at an area under the curve of 0.987, makes the composite objective cheap enough to optimise directly. Over the 622-case public release, a report selected against the visible lexical ranking scores 0.2909, whereas one selected against the composite objective scores 0.4122, because pursuing n-gram overlap drives entailment precision from 0.522 down to 0.266. A 29 million parameter encoder fine-tuned on the release reaches a prevalence-weighted out-of-fold area under the curve of 0.486 over 985 statements, indistinguishable from the corpus prior, while nine numbers read from the image header reach 0.945 for mandible coverage and 0.872 for condyle coverage, and acquisition centre alone predicts sentence choice at 0.718 against 0.663 for the image-derived model, identifying dictation convention rather than anatomy as the quantity the lexical metrics reward. The delivered system emits eight unconditional statements and five gated on header geometry under polarity, laterality and tooth-level consistency constraints, and reaches METEOR 0.3542 over 50 held-out cases from an unseen centre. The dataset and code are available at https://github.com/GIND123/CBCT-Clinical-Reasoner

0.74

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.64
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.16

CheXGround: Anatomical Region Tokens for Grounded Longitudinal Chest X-ray Interpretation

cs.CV ·2026-08-31 ·Adonay Demewez Gebremedhin, Wessam Shehieb, Sara Alansari, Mohamad Alansari, Muzammal Naseer +2 more
publishedcode/data similarity 0.63
Abstract · Accepted for publication at the 37th British Machine Vision Conference (BMVC2026)

Recent radiology multi-modal language models have made substantial progress in chest X-ray report generation, visual question answering, and temporal reasoning. While longitudinal chest X-ray interpretation compares sequential examinations to describe change, visual grounding aims to connect clinical language with localized image evidence. Although longitudinal modeling and visual grounding have each advanced radiology language models, how localized visual evidence can support longitudinal interpretation remains under-explored. We introduce CheXGround, a region-grounded longitudinal chest X-ray language model that represents paired studies through corresponding anatomical regions. CheXGround extracts anatomical regions from current and prior radiographs, encodes them as temporally enhanced Region-of-Interest (ROI) tokens, and combines them with global temporal image context during generation. To connect these region tokens with clinical text, we propose Temporal Region--Phrase Alignment, a pretraining objective that aligns temporal anatomical representations with localized report phrases. We evaluate CheXGround on single-study and longitudinal Visual Question Answering (VQA), longitudinal findings generation, temporal grounded VQA, and anatomical grounding. Across these tasks, CheXGround improves clinical language quality, temporal reasoning, and localization accuracy over recent baselines. Our results suggest that organizing longitudinal evidence at the anatomical level is a strong representation for grounded radiology language modeling. Project page: https://adonaydem.github.io/chexground-website

0.38