CS Paper Radar

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan, Konstantinos Kamnitsas

cs.LG cs.AI ·submitted 2026-08-30 20:23 UTC · v2
benchmark

Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

Closest papers

Nearest neighbours by meaning across the whole index.

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.71
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.70
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.53

ChestPheNoT: Deployable, Auditable Label-Status-Evidence Extraction from Radiology Reports

cs.CL cs.AIcs.LG ·2026-09-09 ·Kai Yu, Chenyu Zhu, Zaifu Zhan, Meijia Song, Min Zeng +3 more
publishedcode/data similarity 0.70
Abstract · Accepted at IEEE Healthcom 2026

Structured phenotype extraction from radiology reports supports cohort construction, quality auditing, and clinical analytics, but practical deployment requires local inference and auditable predictions, while expert annotations remain scarce. Conventional labelers provide structured findings and assertion states but no supporting evidence, while API-hosted large language models may be unsuitable when clinical text cannot leave institutional infrastructure. We present CHESTPHENOT, a compact 0.5-3B language model that jointly extracts finding labels, three-class status (present/absent/uncertain), and verbatim supporting evidence spans. CHESTPHENOT is trained using hybrid CheXbert+72B silver supervision followed by supervised fine-tuning and lightweight GRPO refinement. Across three human-annotated gold sets spanning in-distribution, cross-taxonomy, and cross-institution evaluation, the 3B model remains below its CheXbert silver teacher in distribution but is competitive under distribution shift, significantly surpassing CheXbert on cross-institution detection (+2.0 F1). Task-specific training also enables the 3B model to match or exceed substantially larger prompted models on most detection and status comparisons. For evidence-grounded extraction, over 99% of final evidence spans are locatable in the source report, and the 3B model achieves 47.5 auditable-F1, outperforming Qwen2.5-7B one-shot prompting by 7.6 points and approaching Qwen2.5-72B. These results demonstrate that locally deployable models can provide competitive and directly auditable radiology-report extraction without relying on external inference APIs. Code and the full extraction/judge prompts will be made available at https://github.com/yukkai/ChestPheNoT.

0.43

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.69
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Adversarial Evaluation of Large Language Models for Patient-Friendly Radiology Report Summarization

cs.AI ·2026-11-06 ·Magdalini Paschali, Asad Aali, Arogya Koirala, Andrew Johnston, Katherine McNamara +4 more
similarity 0.68
Abstract · This work has been submitted to Radiology: Artificial Intelligence for possible publication. Copyright may be transferred without notice, af…

Purpose: To develop and validate a scalable adversarial evaluation framework for assessing the robustness of large language models (LLMs) that generate patient-friendly summaries of radiology reports. Methods: We introduced a clinically grounded adversarial framework that uses controlled term substitutions and impression removals across intensity levels. Using a radiologist-validated adversarial dictionary, we generated adversarial variants of CT and MRI reports. Six LLMs summarized original and adversarial impressions using 2 prompt styles, yielding 18,000 evaluation pairs. Robustness was evaluated with an automated LLM-as-a-judge framework scoring factual faithfulness, sensitivity to adversarial edits, certainty fidelity, and hallucination rate. Failure mode analysis quantified vulnerabilities in incorporating clinical modifiers. Agreement with two radiologists was assessed on 105 cases. Results: GPT-5-mini achieved the highest factual faithfulness and certainty fidelity under both adversarial edits. Under term substitution, hallucinations occurred in 28.1-30.1% of GPT-5-mini summaries, compared with 35.3-36.4% for Claude Sonnet 4.5 and 41.4-41.9% for MedGemma. Impression-removal edits were handled more robustly than term substitutions. Even for the highest-scoring summarizer, substitutions of anatomical terms were not reflected in 23.7% of summaries, diagnostic certainty in 22.3%, and descriptor terms (e.g., "substantial") in 21.2%. Judge-radiologist agreement (macro-F1: 0.55-0.56) was comparable to inter-radiologist agreement (0.53). Conclusions: Adversarial evaluation exposes clinically meaningful failure modes, including missed anatomical modifiers, altered diagnostic certainty, and omitted severity descriptors.

0.18

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.68
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32

Toward Better Assessment of LLMs' Performance in Clinical Error Detection

cs.CL cs.AIcs.LG ·2026-08-17 ·Yifan Zhang, Rahmatollah Beheshti
top venuebenchmarkcode/data similarity 0.68
Abstract · Accepted at Machine Learning for Healthcare (MLHC) 2026; to appear in Proceedings of Machine Learning Research (PMLR), Vol. 340

Automated detection of errors in clinical documentation is a promising application of large language models (LLMs), yet decisions to deploy such models rest on benchmarks that evaluate each clinical note in isolation. Error-detection benchmarks are typically constructed by injecting errors into notes, such that each erroneous note has a natural counterpart. Aggregate discriminative metrics (e.g., balanced accuracy or F1) do not exploit this structure. We show that this omission is consequential. In particular, evaluating 15 diverse LLMs on 4 standardized clinical error-detection test sets across 3 languages, we find that 13 of 15 models fall below the level of random pairwise discrimination, even while achieving F1 scores that standard practice would read as moderate. We also observe that the underlying bias patterns differ across languages: the same model can default to "no error" on one language and over-flag errors on another. To diagnose where discrimination breaks down, we further introduce a procedure to score the evidence models cite in their outputs. We find that while models consistently locate error-relevant content, they fail to produce the corresponding correct verdict on the clean counterpart. Finally, we show that F1 and pairwise accuracy are driven in opposite directions by the same underlying bias, so that ranking models by F1 may systematically promote the weakest discriminators. For safety-critical clinical NLP applications, we advocate for supplementing aggregate metrics with paired evaluations in benchmark reporting. Code and analysis scripts are available at https://github.com/healthylaife/paired-clinical-eval.

0.58

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
published similarity 0.67
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.21