CS Paper Radar

ChestPheNoT: Deployable, Auditable Label-Status-Evidence Extraction from Radiology Reports

Kai Yu, Chenyu Zhu, Zaifu Zhan, Meijia Song, Min Zeng, Xiaoyi Chen, Mingquan Lin, Rui Zhang

cs.CL cs.AIcs.LG ·submitted 2026-09-09 00:13 UTC · v1
publishedcode/data

Abstract

Structured phenotype extraction from radiology reports supports cohort construction, quality auditing, and clinical analytics, but practical deployment requires local inference and auditable predictions, while expert annotations remain scarce. Conventional labelers provide structured findings and assertion states but no supporting evidence, while API-hosted large language models may be unsuitable when clinical text cannot leave institutional infrastructure. We present CHESTPHENOT, a compact 0.5-3B language model that jointly extracts finding labels, three-class status (present/absent/uncertain), and verbatim supporting evidence spans. CHESTPHENOT is trained using hybrid CheXbert+72B silver supervision followed by supervised fine-tuning and lightweight GRPO refinement. Across three human-annotated gold sets spanning in-distribution, cross-taxonomy, and cross-institution evaluation, the 3B model remains below its CheXbert silver teacher in distribution but is competitive under distribution shift, significantly surpassing CheXbert on cross-institution detection (+2.0 F1). Task-specific training also enables the 3B model to match or exceed substantially larger prompted models on most detection and status comparisons. For evidence-grounded extraction, over 99% of final evidence spans are locatable in the source report, and the 3B model achieves 47.5 auditable-F1, outperforming Qwen2.5-7B one-shot prompting by 7.6 points and approaching Qwen2.5-72B. These results demonstrate that locally deployable models can provide competitive and directly auditable radiology-report extraction without relying on external inference APIs. Code and the full extraction/judge prompts will be made available at https://github.com/yukkai/ChestPheNoT.

Comment
Accepted at IEEE Healthcom 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

cs.LG cs.AI ·2026-08-30 ·Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan +1 more
benchmark similarity 0.70
Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

0.25

Making Clinical Language Models Auditable: Concept-Guided Fine-Tuning for Robust Prediction

cs.CL cs.AI ·2026-08-27 ·Jin Mu, Guanhua Chen
top venue similarity 0.68
Abstract

Clinical language models can achieve strong in-hospital accuracy yet fail under deployment shifts because they exploit note-specific artifacts (e.g., templates, separators, boilerplate) that do not reflect patient state. We propose CAST (Concept-guided Artifact Suppression Tuning), an SAE-based framework for auditable clinical text classification. CAST uses Sparse Autoencoders to expose sparse, human-auditable features from intermediate Transformer activations, labels SAE latents with an LLM-assisted interpretation pipeline and ICD-10 retrieval constraints, suppresses verified artifact latents via residual subtraction during fine-tuning, and provides post-hoc per-concept attributions for auditing model decisions. On MIMIC-IV discharge-note mortality prediction, CAST improves over its corresponding fine-tuned encoder baselines and remains competitive with strong LLM baselines, while producing a feature-level audit trail of the clinical concepts that support each prediction and the artifact concepts suppressed during training.

0.44

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.68
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Generating Biomedical Fact-Checking Reports with RL-Enhanced Agentic Search

cs.AI ·2026-08-24 ·Jiongxiao Wang, Dingli Ma, Chaoqun Ni
code/data similarity 0.66
Abstract

Automated fact-checking is essential for ensuring the reliability of public health information, yet the biomedical domain poses unique challenges. Validating biomedical claims requires rigorous interpretation of scientific literature, assessment of retrieved evidence, and comprehensive justification toward the conclusion. Although Large Language Models (LLMs) enhanced by Retrieval-Augmented Generation (RAG) and agentic search perform automated fact-checking in a retrieve-then-verify paradigm, current methods still output isolated prediction labels, lacking explanatory depth and offers limited utility for human understanding. To bridge this gap, we introduce an LLM-based agent named BioCheck Agent that generates structured biomedical fact-checking reports with agentic search. Rather than merely outputting supported or refuted labels, our agent synthesizes final conclusions with retrieved evidence and rigorous analysis. To ensure domain-specific accuracy, BioCheck Agent exclusively searches high-quality scientific literature in PubMed, utilizing advanced Boolean search operators. Recognizing that direct prompting often results in hallucinations and low-quality reports, especially for lightweight open-source models, we further propose the Evidence-Grounded Group Relative Policy Optimization (EG-GRPO) to perform reinforcement learning on BioCheck Agent with a task-specific reward that incentivizes advanced search behavior and high-quality evidence retrieval while penalizing hallucinations. Our experimental results show that compared to the base model Qwen3.5-4B, BioCheck Agent with EG-GRPO improves label prediction accuracy on SciFact by 9.95%. Furthermore, it achieves a 3.7% higher evidence quality score and a 19.63% lower evidence hallucination rate, demonstrating its ability to generate biomedical fact-checking reports with improved accuracy and quality.

0.32

Automated Chest CT Protocol Selection via Large Language Model Derived Text Embeddings from Imaging Request Text

cs.LG ·2026-09-07 ·Zahra Hosseini, Mahan Pouromidi, Farzad Khalvati, Patrik Rogalla
similarity 0.66
Abstract

Purpose: Accurate CT protocol selection is critical for diagnostic quality and patient safety, yet the current process is manual, time-consuming, and prone to inconsistencies. Prior Machine Learning methods using keywords or bag-of-words lack contextual understanding and perform poorly on rare protocols. We propose a decision support system using large language model (LLM) features to recommend protocols from free-text clinical indications, capturing clinical nuance and phrasing variation for more consistent, efficient selection. Methods: In this REB-approved retrospective study, 285,123 chest CT imaging requests from a large academic medical center (2017-2024) were split into training (228,099, 80%) and held-out test (57,024, 20%) sets. Each request included procedure names, clinical indication, HIS comments, and the selected protocol. Clinical text was embedded using a fine-tuned LLM, Meta's LLaMA-3.1-70B; these features input a logistic regression classifier predicting 18 protocol labels (e.g., PE, LDCT). Results: The pipeline achieved a weighted precision of 0.84, weighted F1-score of 0.81, and overall accuracy of 79% across 18 CT protocols. On 300 independent cases with expert consensus, the LLM reached an overall accuracy of 80% versus 83% for radiologists, with no significant difference (p = 0.263). Performance was comparable across most classes, with the LLM exceeding radiologists for some challenging categories, and entropy analyses indicated more balanced protocol use, suggesting reduced variability. Conclusion: An LLM-based recommendation system can leverage general knowledge from a large natural-text corpus to accurately assign chest CT protocols from free-text imaging requests, and may serve as a viable foundation for protocol recommendation tools where inputs require language understanding.

0.15

templar: agentic induction and evolution of standardized radiology reporting templates from large-scale clinical corpora

cs.MA cs.CL ·2026-10-04 ·Xiaotian Hu, Mingxuan Liu, Zhonghan Wang, Xinfeng Zhang, Yiming Huang +7 more
similarity 0.65
Abstract

Structured radiology reporting mitigates the heterogeneity of free-text reports, yet its benefits depend on high-quality reporting templates. In practice, such templates are conventionally built through labor-intensive expert consensus and therefore vary across institutions and lag behind evolving clinical practice. Large language models (LLMs) enable automated template induction, but existing approaches remain limited: single-LLM induction is constrained by context length, and the corpus-scale method ASTAR produces a static, closed-corpus template without external grounding or downstream adaptation. To address these limitations, we propose TEMPLAR, a TEMPLate-centric Agentic framework for inducing and evolving standardized Radiology reporting templates from large-scale clinical corpora. TEMPLAR treats the template as a persistent central state maintained alongside two provenance-aware knowledge graphs, namely an anatomical graph that constrains template construction and a diagnostic graph that supports finding-to-diagnosis reasoning. Three agents operate on this state. The Induction Agent derives canonical clinical slots from anatomy-constrained Span-Triple atoms via dual-view similarity clustering; the Evolution Agent then assembles these slots into a hierarchical template and revises it under consistency constraints, external clinical evidence, and downstream structuring feedback; and the Clinical Agent applies the evolved template to report structuring, reconstruction, and diagnostic reasoning. Across four datasets, TEMPLAR outperforms ASTAR, three medical LLMs, and six general-purpose LLMs in coverage, information fidelity, and diagnostic fidelity, while achieving the highest or tied-highest LLM-rated template quality. Its fidelity advantages over ASTAR persist under cross-dataset transfer, and cumulative ablations support complementary contributions of its key components.

0.10

Comparison of techniques for fine-tuning open-weight models for entity extraction from radiology reports

cs.CL cs.LG ·2026-09-30 ·Aawez Mansuri, Kush Mehta, Mohammadreza Chavoshi, Jahanzaib Malik, Theodorus Dapamede +8 more
similarity 0.65
Abstract

Converting free-text radiology reports into structured labels supports cohort building, quality assurance, and monitoring of clinical imaging models, but the strongest label extractors are hosted proprietary models whose use raises privacy, cost, and reproducibility concerns. We asked whether a fine-tuned open-weight model (Gemma-3-12B) can match GPT-4o at multi-label intracranial hemorrhage (ICH) acuity extraction from non-contrast head-CT reports, and which ingredients matter. Using a 2x2 design, we crossed two adaptation strategies (a discriminative classification head, CH; generative instruction fine-tuning, IFT) with two training-data sources (distillation of real GPT-4o-labeled reports; synthetic reports generated by GPT-4o from real exemplars), across five training sizes, benchmarked on 100 expert-adjudicated reports against GPT-4o and the un-tuned open-weight base. The distilled instruction-tuned model (DIFT) matched GPT-4o (macro-F1 0.845 vs 0.850; p = 1.000) and exceeded the base model by 0.178. The decisive factor was the training-data source, not the fine-tuning method: both synthetic-data models failed to exceed the un-tuned open-weight base at any training size and underperformed the distilled models across all acuity classes. Fine-tuning and inference fit within the memory envelope of a single 24 GB consumer GPU. For narrow, high-value clinical label-extraction tasks, distilling real reports, rather than generating synthetic ones, is what closes the gap to a hosted model, enabling a private, low-cost, version-stable on-premises alternative.

0.23

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

cs.CV ·2026-08-26 ·Juan Iñaki Larrea, Lucas Mansilla, Enzo Ferrante
published similarity 0.65
Abstract · Accepted at MIRASOL Workshop, MICCAI 2026. 10 pages, 3 figures

Foundation models are increasingly deployed for medical image analysis. However, under the inter-institutional distribution shift typical of deployment, their performance varies widely and cannot be known without target-domain labels, which are rarely available. This leaves a practical question unresolved: given several candidate foundational models and labeled-data from a source domain, which one to deploy in an unlabeled target domain? We propose a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations. SUDO partitions the unlabeled target data by predicted probability and, for each region, measures a pseudo-label discrepancy reflecting class contamination; aggregated across regions, this yields a score (AURCC) requiring neither target annotation nor fine-tuning. We show that AURCC can be used to rank a variety of vision-language models (BioMedCLIP, CXR-CLIP, CheXzero, MedCLIP, MedImageInsight, CLIP) on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes. The AURCC ranking recovers the ground-truth ranking with Spearman rho up to 0.943 (p<0.05). Against the natural baseline of ranking by held-out source accuracy, AURCC is competitive when the labeled source is large and yields a more accurate ranking once it is small; the regime of interest in resource-constrained settings.

0.19