CS Paper Radar

Comparison of techniques for fine-tuning open-weight models for entity extraction from radiology reports

Aawez Mansuri, Kush Mehta, Mohammadreza Chavoshi, Jahanzaib Malik, Theodorus Dapamede, Frank Li, Rohan Isaac, Beatrice Brown-Mulry, Chiratidzo Rudado Sanyika, YoungSeok Jeon, Judy W. Gichoya, Ali Emami, Hari Trivedi

cs.CL cs.LG ·submitted 2026-09-30 17:32 UTC · v1

Abstract

Converting free-text radiology reports into structured labels supports cohort building, quality assurance, and monitoring of clinical imaging models, but the strongest label extractors are hosted proprietary models whose use raises privacy, cost, and reproducibility concerns. We asked whether a fine-tuned open-weight model (Gemma-3-12B) can match GPT-4o at multi-label intracranial hemorrhage (ICH) acuity extraction from non-contrast head-CT reports, and which ingredients matter. Using a 2x2 design, we crossed two adaptation strategies (a discriminative classification head, CH; generative instruction fine-tuning, IFT) with two training-data sources (distillation of real GPT-4o-labeled reports; synthetic reports generated by GPT-4o from real exemplars), across five training sizes, benchmarked on 100 expert-adjudicated reports against GPT-4o and the un-tuned open-weight base. The distilled instruction-tuned model (DIFT) matched GPT-4o (macro-F1 0.845 vs 0.850; p = 1.000) and exceeded the base model by 0.178. The decisive factor was the training-data source, not the fine-tuning method: both synthetic-data models failed to exceed the un-tuned open-weight base at any training size and underperformed the distilled models across all acuity classes. Fine-tuning and inference fit within the memory envelope of a single 24 GB consumer GPU. For narrow, high-value clinical label-extraction tasks, distilling real reports, rather than generating synthetic ones, is what closes the gap to a hosted model, enabling a private, low-cost, version-stable on-premises alternative.

Closest papers

Nearest neighbours by meaning across the whole index.

ChestPheNoT: Deployable, Auditable Label-Status-Evidence Extraction from Radiology Reports

cs.CL cs.AIcs.LG ·2026-09-09 ·Kai Yu, Chenyu Zhu, Zaifu Zhan, Meijia Song, Min Zeng +3 more
publishedcode/data similarity 0.65
Abstract · Accepted at IEEE Healthcom 2026

Structured phenotype extraction from radiology reports supports cohort construction, quality auditing, and clinical analytics, but practical deployment requires local inference and auditable predictions, while expert annotations remain scarce. Conventional labelers provide structured findings and assertion states but no supporting evidence, while API-hosted large language models may be unsuitable when clinical text cannot leave institutional infrastructure. We present CHESTPHENOT, a compact 0.5-3B language model that jointly extracts finding labels, three-class status (present/absent/uncertain), and verbatim supporting evidence spans. CHESTPHENOT is trained using hybrid CheXbert+72B silver supervision followed by supervised fine-tuning and lightweight GRPO refinement. Across three human-annotated gold sets spanning in-distribution, cross-taxonomy, and cross-institution evaluation, the 3B model remains below its CheXbert silver teacher in distribution but is competitive under distribution shift, significantly surpassing CheXbert on cross-institution detection (+2.0 F1). Task-specific training also enables the 3B model to match or exceed substantially larger prompted models on most detection and status comparisons. For evidence-grounded extraction, over 99% of final evidence spans are locatable in the source report, and the 3B model achieves 47.5 auditable-F1, outperforming Qwen2.5-7B one-shot prompting by 7.6 points and approaching Qwen2.5-72B. These results demonstrate that locally deployable models can provide competitive and directly auditable radiology-report extraction without relying on external inference APIs. Code and the full extraction/judge prompts will be made available at https://github.com/yukkai/ChestPheNoT.

0.43

FedPref: Federated Preference Learning for Structured Radiology Report Extraction

cs.AI cs.LG ·2026-08-17 ·Flint Xiaofeng Fan, Cheston Tan, Yew-Soon Ong, Roger Wattenhofer
published similarity 0.64
Abstract · Accepted at ELAMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer proceedings

Radiology reports describe findings and locations in free text, but downstream search and analysis require these relations in a fixed schema. Learning this extraction requires labels that are unevenly distributed across institutions: smaller hospitals have less local evidence, and pooling data may be infeasible. We introduce FedPref: frozen public language models propose alternative JSON extractions, local annotations rank them, and sites collaboratively train compact Qwen3-8B adapters while sharing only model updates. A heterogeneous teacher pool provides cross-model contrast when repeated single-model samples collapse. On development data from six simulated hospitals with unequal data volume and disease prevalence, FedPref improves client-mean F1 by 2.49 points and worst-site F1 by 9.10 points compared with training each site in isolation, with the largest gains at the sites holding the least data. Central training on the pooled preference-pair union is 2.66 points higher on client-mean F1. On a locked, 400-report manually validated gold test set, FedPref reaches 68.68 F1 and pooled training 71.67, preserving that same ordering. FedPref thus lets institutions with unequal, unpooled data benefit from collaboration without ever sharing reports or annotations.

0.60

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

cs.CV cs.LG ·2026-11-17 ·Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
published similarity 0.63
Abstract · 25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower H…

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

0.37

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

cs.AI cs.CL ·2026-10-03 ·Friedrich Puttkammer, Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf +17 more
similarity 0.63
Abstract · 27 pages, 9 figures

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

0.19

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

cs.LG cs.AI ·2026-08-30 ·Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan +1 more
benchmark similarity 0.63
Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

0.25

QureRadEmbed: Structuring Radiological Similarity through Attribute and Reasoning Supervision

cs.AI ·2026-09-27 ·Janhavi Prabhu, Sahil, Shivam Ashok Shukla, Manoj Tadepalli
benchmark similarity 0.63
Abstract · 39 pages, 10 figures, including appendices with per-tag labeling results. Janhavi Prabhu and Sahil are co-first authors. Manoj Tadepalli is …

Radiological similarity depends on disease relationships and on fine details such as laterality, lobe, severity, size, and certainty. Broad biomedical similarity can overlook these qualifiers, particularly when several attributes vary together. We introduce QureRadEmbed, a 4B radiology-aware encoder trained with two complementary signals: RadSim supplies deterministic, attribute-decomposed ranking targets, while RadThought aligns reports with hierarchical evidence and reasoning descriptions. A three-stage curriculum combines these signals with report triplets, finding perturbations, and single- and cross-attribute contrasts. The final model achieves 0.996 mean ordering accuracy across ten controlled synthetic attributes and raises Spearman correlation with the designed joint-attribute targets from 0.501 to 0.976. On external findings-to-impression retrieval, Recall@1 reaches 10.5% on Open-I, 12.4% on testing XR, and 42.9% on testing CT, compared with 6.6%, 5.7%, and 31.4% for its backbone. Frozen embeddings support finding extraction with only 100 labeled testing-XR reports (macro-F1 0.481 versus 0.412 for the backbone). Whole-report comparison costs 8.8 seconds per 1,000 pairs in our benchmark, versus 2,755.1 seconds for the generative evaluator GREEN. Sentence-level comparison improves sensitivity to local discrepancies, although generative evaluation remains stronger on several expert-rated and subtle-error tasks. The results support reusable radiology-aware representations for search, structured report indexing, and efficient report comparison.

0.24

CARET: Clinical Assertion-Aware Residual Calibration for Medical Image-Text Alignment

cs.CV cs.AI ·2026-11-13 ·Yifan Jin, Tao Liu
similarity 0.63
Abstract

Medical vision--language models align radiographs with free-text reports, but radiology language distinguishes explicit findings, negation, uncertainty, and omission. Treating these report states as interchangeable during feature adaptation can change image predictions without supporting visual evidence. We introduce CARET, a parameter-efficient image-side adaptation method that retains pretrained image and text encoders and uses paired positive and negative clinical statements to define a low-dimensional semantic correction space. A bounded residual adjusts image features along these directions, while assertion-aware supervision distinguishes explicitly present and absent findings from uncertain or unmentioned ones. At inference, the adapter requires only an image; textual references remain fixed. In zero-shot classification, CARET achieves 67.80\% accuracy on CheXpert 5$\times$200 and 65.20\% on RSNA. These scores exceed the published CLEFT-LoRA results by 1.06 and 0.27 percentage points, respectively. Comparisons to literature baselines are informative but not controlled for differences in pretraining and evaluation protocols. Ablations across eight components identify the four-state distinction and assertion objective as major contributors, with task-dependent effects for nonmention preservation and pair alignment.

0.19

Pre-training, Reasoning, Benchmarking: X-ray Report Generation on CheXpert Plus Dataset

cs.CV cs.AI ·2026-09-23 ·Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang +4 more
benchmarkcode/data similarity 0.62
Abstract

X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potential to alleviate clinicians' diagnostic workload and shorten patient waiting periods. Despite substantial advances over recent years, the field faces evident bottlenecks stemming from insufficient standardized benchmarks and inadequate domain adaptation of generic large models. Notably, the newly released CheXpert Plus dataset is provided without accompanying baseline implementations and evaluation results, which impedes standardized training, quantitative evaluation and fair comparison among follow-up algorithms. To mitigate this limitation, we establish a comprehensive benchmark encompassing prevailing X-ray report generation models and Large Language Models on CheXpert Plus. This benchmark delivers a reliable comparative foundation for upcoming methods and enables researchers to rapidly identify state-of-the-art approaches within this domain. Beyond benchmark construction, we rethink X-ray RRG under the paradigm of large models and propose a novel framework termed MambaXray-PRB. Our framework improves report generation performance and enhances model interpretability via multi-stage large-model pre-training and multi-modal Chain-of-Thought reasoning. The pipeline consists of three successive phases: self-supervised auto-regressive modeling, X-ray-report contrastive learning, and post-training optimization for reasoning and report generation. Extensive experiments on IU X-ray, MIMIC-CXR, and CheXpert Plus datasets validate the effectiveness of MambaXray-PRB for radiology report generation. The source code of this paper is available on https://github.com/Event-AHU/Medical_Image_Analysis

0.32