CS Paper Radar

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen

cs.CV cs.LG ·submitted 2026-11-17 10:00 UTC · v1
published

Abstract

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

Comment
25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower HCC classification performance; the main findings on temperature initialization and better VerSe performance retention with PEFT remain supported
Journal ref
Proceedings of the 9th International Conference on Medical Imaging with Deep Learning, PMLR 315:3245-3269, 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.71
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.51

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.69
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

MVC-Bench: Benchmarking Calibration of Medical Vision-Language Models

cs.CV ·2026-08-27 ·Ashshak Sharifdeen, Shihab Aaqil Ahamed, Ufaq Khan, Muhammad Akhtar Munir, Sujair Ibrahim +4 more
top venuebenchmark similarity 0.69
Abstract · Accepted in EMNLP 2026 Findings

Reliable evaluation of vision-language models (VLMs) and medical vision-language models (Medical-VLMs) requires calibrated confidence, particularly under realistic clinical conditions. However, existing efforts mainly focused on improving accuracy, leaving calibration in the medical domain underexplored. To this end, we propose MVC-Bench, a calibration-centric benchmark for medical image classification with VLMs and Medical-VLMs. MVC-Bench assesses the calibration across three axes: (i) robustness to modality, backbone, and domain shift (ii) effectiveness of calibration strategies and prompt-tuning methods (iii) stability under prompt-template and random-seed variations. The benchmark covers eight different backbones, three medical modalities, including fundus imaging, histopathology, and chest X-ray under in-domain and domain shift settings. It compares post-hoc calibration, train-time calibration, and zero-shot inference methods, together with six prompt-tuning methods. Across more than 1638 controlled experiments, we report accuracy and Expected Calibration Error (ECE) as primary metrics, and further report results with complementary calibration measures, including Maximum Calibration Error (MCE) and Adaptive Calibration Error (ACE). We further investigate the underlying causes of miscalibration in VLMs and Medical-VLMs and propose a simple train-time calibration method, Multi-Class Margin (MCM) regularization, which achieves lowest ECE on 10 out of 12 settings in in-domain and remains competitive under domain shifts. Collectively, MVC-Bench provides a structured evaluation framework and actionable guidance for improving calibration in safety-critical medical workflows.

0.58

LiFUSE: Frequency-Spatial Unified Self-Supervised Pretraining for Liver Disease Analysis on Non-contrast CT

cs.CV cs.AIcs.LG ·2026-10-13 ·Hao Zhang, Yi Huang, Wei Liu, Yuan Gao, Zeju Li +4 more
published similarity 0.69
Abstract · Accepted at the 2026 IEEE International Conference on Bioinformatics and Biomedicine (BIBM 2026)

Given the growing global burden of liver tumors and diffuse liver diseases, non-contrast computed tomography (NCCT) is increasingly used for opportunistic screening because of its low cost and favorable safety profile. However, downstream tasks such as tumor detection and fine-grained disease diagnosis remain challenging due to NCCT's inherently low tissue contrast, lack of hemodynamic enhancement, and complex anatomical background. These limitations make subtle, heterogeneous, and multifocal hepatic lesions difficult to identify. Although large-scale self-supervised pretraining can learn robust representations from unlabeled NCCT scans, conventional voxel-wise reconstruction does not fully exploit the complementary information available in NCCT. Under weak NCCT contrast, low-level intensity patterns become less informative for pathology recognition, limiting the capture of lesion-specific discriminative features. In this paper, we propose the Liver Frequency-Spatial Unified Self-Supervised Pretraining (LiFUSE). The frequency branch applies random band-stop masking and spectrum reconstruction to encourage the model to capture subtle differences between lesions and surrounding tissues, while the spatial branch performs hybrid-granularity masked volumetric reconstruction to accommodate lesions of diverse sizes and morphologies. Finally, a cross-domain consistency scheme couples the spatial and frequency branches, yielding more discriminative representations for hepatic structures and lesions. Extensive experiments on three clinically relevant tasks across internal cohorts and a public target-domain transfer setting show that LiFUSE consistently outperforms strong baselines. These results suggest that unified frequency-spatial learning can improve liver disease analysis on NCCT, highlighting its potential for large-scale screening.

0.16

CARET: Clinical Assertion-Aware Residual Calibration for Medical Image-Text Alignment

cs.CV cs.AI ·2026-11-13 ·Yifan Jin, Tao Liu
similarity 0.67
Abstract

Medical vision--language models align radiographs with free-text reports, but radiology language distinguishes explicit findings, negation, uncertainty, and omission. Treating these report states as interchangeable during feature adaptation can change image predictions without supporting visual evidence. We introduce CARET, a parameter-efficient image-side adaptation method that retains pretrained image and text encoders and uses paired positive and negative clinical statements to define a low-dimensional semantic correction space. A bounded residual adjusts image features along these directions, while assertion-aware supervision distinguishes explicitly present and absent findings from uncertain or unmentioned ones. At inference, the adapter requires only an image; textual references remain fixed. In zero-shot classification, CARET achieves 67.80\% accuracy on CheXpert 5$\times$200 and 65.20\% on RSNA. These scores exceed the published CLEFT-LoRA results by 1.06 and 0.27 percentage points, respectively. Comparisons to literature baselines are informative but not controlled for differences in pretraining and evaluation protocols. Ablations across eight components identify the four-state distinction and assertion objective as major contributors, with task-dependent effects for nonmention preservation and pair alignment.

0.19

Meta-CLIP: Metadata-Conditioned Contrastive Learning for Zero-Shot Disease Inference

cs.AI cs.CL ·2026-10-24 ·Haozhe Luo, Nirosh Sivanesan, Shelley Zixin Shu, Francesco Nitti, Mauricio Reyes
code/data similarity 0.67
Abstract

Medical vision--language pretraining learns transferable representations from paired images and radiology reports, yet differences in scanners and acquisition protocols can impair transfer. Existing approaches primarily enrich clinical semantics, leaving structured acquisition information in DICOM headers underused. We introduce Meta-CLIP, a metadata-conditioned contrastive framework that uses acquisition similarity to reweight cross-modal negatives during pretraining. A kernel over numerical and categorical DICOM fields defines a bounded pairwise margin. This margin increases the contribution of acquisition-similar negatives, emphasizing distinctions among studies that share imaging conditions. The kernel remains fixed during image--text optimization, and inference follows the standard dual-encoder architecture without requiring metadata. We evaluate Meta-CLIP on chest radiography and volumetric chest CT through zero-shot classification, appearance perturbations, grounding, and representation analyses. On CT-RATE, Meta-CLIP improves macro-AUROC over CT-CLIP by 1.41 points, with a 95\% paired bootstrap confidence interval of 0.96--1.85 points. It also achieves the highest macro-AUROC on four of five CXR benchmarks. An exploratory BrgSA evaluation extends the analysis to another CT backbone. These findings support acquisition metadata as a practical training-time prior for medical vision--language learning. Code will be made publicly available upon publication.

0.32

Uni-Loc: Weakly Supervised 3D CT Pathology Localization via Spatially Grounded Vision-Language Classification

cs.CV ·2026-11-09 ·Hao-Chih Lee, Zahi A. Fayad, Xueyan Mei
similarity 0.66
Abstract

Accurate localization of abnormalities in three-dimensional (3D) CT scans is essential for linking automated predictions with clinically relevant pathological findings. We propose Uni-Loc, a vision-language framework that unifies pathology classification and 3D localization using scan-level supervision. Uni-Loc derives both predictions and localization maps from spatial similarities between pathology-conditioned queries and image features. A token-to-voxel upsampling module enables high-resolution localization, while gradient-guided thresholding identifies pathology regions without additional learned parameters. Evaluated on five localization tasks comprising 355 annotated CT scans, Uni-Loc achieves macro-averaged voxel-level AUROC/AUPR of 96.1\%/34.5\%, outperforming relevance propagation (80.7%/13.9%) and gradient saliency (88.7%/8.1%). Uni-Loc also achieves classification AUROC of 88.39% on CT-RATE and 78.03% on RAD-ChestCT, improving over a matched baseline. These results demonstrate effective 3D pathology localization without requiring pathology-specific voxel-level supervision.

0.12

ViCoR: Estimating Visual Necessity via Counterfactual Residuals for Multimodal Medical Data Selection

cs.LG cs.AI ·2026-10-18 ·Haotian Gan, Yudong Li, Xintian Li, Jiarui Han, Weidong Tang
top venuebenchmarkcode/data similarity 0.66
Abstract · Accepted to NeurIPS2026

Medical vision-language models often exhibit hidden stratification, where high overall performance masks failures on subtle visual findings and overlapping clinical conditions. We trace this failure mode to modality imbalance during fine-tuning, where strong linguistic priors can suppress visually grounded learning and induce plausible but weakly grounded rationales. Existing data selection methods usually score image-text pairs as holistic units, without separating visually necessary samples from shortcut-solvable ones. To address this problem, we propose ViCoR, a counterfactual-residual-based data selection method for Med-VLM fine-tuning. ViCoR estimates visual necessity through image-dependent optimization residuals, calibrates the resulting scores with medical supervision compatibility, and constructs a diversity-aware fine-tuning subset. Across two backbones, four external generalization benchmarks, and one multi-disease robustness benchmark, ViCoR-selected 20\% subsets achieve the strongest average performance compared with full-data fine-tuning and selection baselines. Gradient-level analysis and perturbation audits further show that ViCoR enriches image-dependent training signals and strengthens image-level and evidence-region dependence. The code will be available at https://github.com/htgan-ai/ViCoR.

0.40