CS Paper Radar

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

Friedrich Puttkammer, Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf, Lena Schmitzer, Lea Schumann, Lina Xu, Johannes Moll, Jannik Lübberstedt, Zeineb Ben Chaaben, Anirudh Narayanan, Hartmut Häntze, Renato Cuocolo, Antonios Billis, Alexander Löser, Jawed Nawabi, Marcus R. Makowski, Cosmin I. Bercea, Shahrooz Faghihroohi, Lisa C. Adams, Keno K. Bressem

cs.AI cs.CL ·submitted 2026-10-03 14:15 UTC · v1

Abstract

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

Comment
27 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.66
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.64
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.54

Comparison of techniques for fine-tuning open-weight models for entity extraction from radiology reports

cs.CL cs.LG ·2026-09-30 ·Aawez Mansuri, Kush Mehta, Mohammadreza Chavoshi, Jahanzaib Malik, Theodorus Dapamede +8 more
similarity 0.63
Abstract

Converting free-text radiology reports into structured labels supports cohort building, quality assurance, and monitoring of clinical imaging models, but the strongest label extractors are hosted proprietary models whose use raises privacy, cost, and reproducibility concerns. We asked whether a fine-tuned open-weight model (Gemma-3-12B) can match GPT-4o at multi-label intracranial hemorrhage (ICH) acuity extraction from non-contrast head-CT reports, and which ingredients matter. Using a 2x2 design, we crossed two adaptation strategies (a discriminative classification head, CH; generative instruction fine-tuning, IFT) with two training-data sources (distillation of real GPT-4o-labeled reports; synthetic reports generated by GPT-4o from real exemplars), across five training sizes, benchmarked on 100 expert-adjudicated reports against GPT-4o and the un-tuned open-weight base. The distilled instruction-tuned model (DIFT) matched GPT-4o (macro-F1 0.845 vs 0.850; p = 1.000) and exceeded the base model by 0.178. The decisive factor was the training-data source, not the fine-tuning method: both synthetic-data models failed to exceed the un-tuned open-weight base at any training size and underperformed the distilled models across all acuity classes. Fine-tuning and inference fit within the memory envelope of a single 24 GB consumer GPU. For narrow, high-value clinical label-extraction tasks, distilling real reports, rather than generating synthetic ones, is what closes the gap to a hosted model, enabling a private, low-cost, version-stable on-premises alternative.

0.23

Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation

cs.CL ·2026-08-18 ·Iryna Hartsock, Cesar Lam, Christopher Otteni, Aliya Qayyum, Robert Gatenby +2 more
similarity 0.63
Abstract · 14 pages, 2 figures, 4 tables

Purpose: To develop and evaluate a locally deployed multi-agent AI system for radiology report structuring and quality assurance. Materials and Methods: This retrospective study included 638 radiology reports from CT examinations of the chest, abdomen, and pelvis dictated by 15 board-certified radiologists in 2023 and 2024. A multi-agent AI pipeline was developed to perform report structuring and quality assurance (QA). The system structured the report into standardized anatomical sections at the sentence level using regex rules and local large language models. It also detected mismatches between the Findings and Impression sections, or within sections; gender-anatomy conflicts; and undocumented communication of critical findings. Two board-certified radiologists independently evaluated a 45-report subset. Results: The multi-agent system structured the Findings sections of all reports (22,270 sentences) into a predefined anatomical format while retaining the original report content. The system flagged 90 (14.1%) reports, most commonly for section mismatches (80 reports, 12.5%). In the radiologist evaluation, both reviewers agreed that 31 (69%) were correctly restructured, 2 reports (4%) were incorrectly restructured, and disagreed on the remaining 12 reports (27%). Both reviewers agreed that no clinically important information was omitted and no fabricated content was introduced. Overall QA performance was rated as "excellent" or "good" in 84% of the evaluated reports, with the remaining reports rated as "fair". Conclusion: A locally deployed multi-agent AI system combined radiology report structuring and quality assurance within a single workflow. The system demonstrated favorable performance in radiologist evaluation. Such systems may support standardization of reporting and quality assurance in radiology practice.

0.37

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
similarity 0.62
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.13

Corpus Characterization and Inverse Constitutional Fine-Tuning for Style-Aware Radiology Reports

cs.CL ·2026-09-13 ·Sarah Y. Li, Elijah Renner, Rayan Ansari, Alaa Youssef
similarity 0.62
Abstract

Automated radiology report generation has advanced rapidly in diagnostic accuracy, yet generated reports frequently diverge from the stylistic conventions of authentic radiologist writing in structure, diction, and uncertainty language, a gap which has direct implications for clinician trust and user experience. To address this, we characterize stylistic variation across 2,000 reports from the CheXpert Plus dataset using Bio-ClinicalBERT embeddings, UMAP dimensionality reduction, and HDBSCAN clustering, identifying five distinct reporting patterns differing in pathology focus, narrative structure, and lexical preference. Drawing on these findings, we adapt the inverse constitutional AI framework to derive a style-focused constitution from radiologist-written report pairs without requiring a formal preference dataset. This constitution, encoding conventions of tone, diction, uncertainty calibration, and report structure, is incorporated into the supervised fine-tuning of a MedGemma-4B base model on 25,245 CheXpert Plus training pairs. Constitutional fine-tuning produces a substantial increases in text alignment (BLEU-4: 0.006 to 0.308; ROUGE-L: 0.171 to 0.484) relative to the untuned baseline. These gains show a qualitative shift in structural and lexical alignment rather than marginal improvement, as the baseline model produces near-zero scores due to format mismatch. Overall, we establish corpus-level style characterization and constitutional modeling as an effective and data-efficient strategy for producing radiology reports that conform to authentic radiologist writing conventions.

0.32

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.61
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.21

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

cs.LG ·2026-11-06 ·Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner +3 more
similarity 0.61
Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

0.21