CS Paper Radar

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner, Lisa Koch, Saif Afat, Michael Muehlebach

cs.LG ·submitted 2026-11-06 22:36 UTC · v1

Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

Closest papers

Nearest neighbours by meaning across the whole index.

Adversarial Evaluation of Large Language Models for Patient-Friendly Radiology Report Summarization

cs.AI ·2026-11-06 ·Magdalini Paschali, Asad Aali, Arogya Koirala, Andrew Johnston, Katherine McNamara +4 more
similarity 0.73
Abstract · This work has been submitted to Radiology: Artificial Intelligence for possible publication. Copyright may be transferred without notice, af…

Purpose: To develop and validate a scalable adversarial evaluation framework for assessing the robustness of large language models (LLMs) that generate patient-friendly summaries of radiology reports. Methods: We introduced a clinically grounded adversarial framework that uses controlled term substitutions and impression removals across intensity levels. Using a radiologist-validated adversarial dictionary, we generated adversarial variants of CT and MRI reports. Six LLMs summarized original and adversarial impressions using 2 prompt styles, yielding 18,000 evaluation pairs. Robustness was evaluated with an automated LLM-as-a-judge framework scoring factual faithfulness, sensitivity to adversarial edits, certainty fidelity, and hallucination rate. Failure mode analysis quantified vulnerabilities in incorporating clinical modifiers. Agreement with two radiologists was assessed on 105 cases. Results: GPT-5-mini achieved the highest factual faithfulness and certainty fidelity under both adversarial edits. Under term substitution, hallucinations occurred in 28.1-30.1% of GPT-5-mini summaries, compared with 35.3-36.4% for Claude Sonnet 4.5 and 41.4-41.9% for MedGemma. Impression-removal edits were handled more robustly than term substitutions. Even for the highest-scoring summarizer, substitutions of anatomical terms were not reflected in 23.7% of summaries, diagnostic certainty in 22.3%, and descriptor terms (e.g., "substantial") in 21.2%. Judge-radiologist agreement (macro-F1: 0.55-0.56) was comparable to inter-radiologist agreement (0.53). Conclusions: Adversarial evaluation exposes clinically meaningful failure modes, including missed anatomical modifiers, altered diagnostic certainty, and omitted severity descriptors.

0.18

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.72
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

cs.CV ·2026-10-15 ·Shrish Shrinath Vaidya, Gowthamaan Palani, Minmini Selvam, Gokulraja Srinivasaraja, Ganapathy Krishnamurthi
published similarity 0.70
Abstract · The paper has been accepted at ECCV BISCUIT Workshop, 2026

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.

0.22

Corpus Characterization and Inverse Constitutional Fine-Tuning for Style-Aware Radiology Reports

cs.CL ·2026-09-13 ·Sarah Y. Li, Elijah Renner, Rayan Ansari, Alaa Youssef
similarity 0.68
Abstract

Automated radiology report generation has advanced rapidly in diagnostic accuracy, yet generated reports frequently diverge from the stylistic conventions of authentic radiologist writing in structure, diction, and uncertainty language, a gap which has direct implications for clinician trust and user experience. To address this, we characterize stylistic variation across 2,000 reports from the CheXpert Plus dataset using Bio-ClinicalBERT embeddings, UMAP dimensionality reduction, and HDBSCAN clustering, identifying five distinct reporting patterns differing in pathology focus, narrative structure, and lexical preference. Drawing on these findings, we adapt the inverse constitutional AI framework to derive a style-focused constitution from radiologist-written report pairs without requiring a formal preference dataset. This constitution, encoding conventions of tone, diction, uncertainty calibration, and report structure, is incorporated into the supervised fine-tuning of a MedGemma-4B base model on 25,245 CheXpert Plus training pairs. Constitutional fine-tuning produces a substantial increases in text alignment (BLEU-4: 0.006 to 0.308; ROUGE-L: 0.171 to 0.484) relative to the untuned baseline. These gains show a qualitative shift in structural and lexical alignment rather than marginal improvement, as the baseline model produces near-zero scores due to format mismatch. Overall, we establish corpus-level style characterization and constitutional modeling as an effective and data-efficient strategy for producing radiology reports that conform to authentic radiologist writing conventions.

0.32

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.67
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.67
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.54

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
published similarity 0.66
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.21

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.66
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40