CS Paper Radar

Adversarial Evaluation of Large Language Models for Patient-Friendly Radiology Report Summarization

Magdalini Paschali, Asad Aali, Arogya Koirala, Andrew Johnston, Katherine McNamara, Richard Gaus, Roxana Daneshjou, David B. Larson, Akshay S. Chaudhari

cs.AI ·submitted 2026-11-06 22:23 UTC · v1

Abstract

Purpose: To develop and validate a scalable adversarial evaluation framework for assessing the robustness of large language models (LLMs) that generate patient-friendly summaries of radiology reports. Methods: We introduced a clinically grounded adversarial framework that uses controlled term substitutions and impression removals across intensity levels. Using a radiologist-validated adversarial dictionary, we generated adversarial variants of CT and MRI reports. Six LLMs summarized original and adversarial impressions using 2 prompt styles, yielding 18,000 evaluation pairs. Robustness was evaluated with an automated LLM-as-a-judge framework scoring factual faithfulness, sensitivity to adversarial edits, certainty fidelity, and hallucination rate. Failure mode analysis quantified vulnerabilities in incorporating clinical modifiers. Agreement with two radiologists was assessed on 105 cases. Results: GPT-5-mini achieved the highest factual faithfulness and certainty fidelity under both adversarial edits. Under term substitution, hallucinations occurred in 28.1-30.1% of GPT-5-mini summaries, compared with 35.3-36.4% for Claude Sonnet 4.5 and 41.4-41.9% for MedGemma. Impression-removal edits were handled more robustly than term substitutions. Even for the highest-scoring summarizer, substitutions of anatomical terms were not reflected in 23.7% of summaries, diagnostic certainty in 22.3%, and descriptor terms (e.g., "substantial") in 21.2%. Judge-radiologist agreement (macro-F1: 0.55-0.56) was comparable to inter-radiologist agreement (0.53). Conclusions: Adversarial evaluation exposes clinically meaningful failure modes, including missed anatomical modifiers, altered diagnostic certainty, and omitted severity descriptors.

Comment
This work has been submitted to Radiology: Artificial Intelligence for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

cs.LG ·2026-11-06 ·Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner +3 more
similarity 0.73
Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

0.21

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

cs.LG cs.AI ·2026-08-30 ·Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan +1 more
benchmark similarity 0.68
Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

0.25

Visually Irrelevant Hallucinations in Medical Vision-Language Models

cs.CV ·2026-10-28 ·Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He +7 more
benchmark similarity 0.66
Abstract

Medical vision-language models (VLMs) show strong performance in radiology report generation (RRG) and medical visual question answering (Med-VQA), producing free-form clinical descriptions and answers from medical images. However, they may generate clinically meaningful statements that lack visual evidence or contradict image content. We refer to these errors as visually irrelevant hallucinations and investigate them at the phrase level. We propose CLEAR (Counterfactual Localized Evaluation of Alignment and Response), a model-agnostic post-hoc framework for phrase-level hallucination risk estimation. CLEAR decomposes generated responses into visually assessable clinical phrases. For each phrase, phrase-conditioned grounding identifies a candidate visual region, which is selectively perturbed by a localized counterfactual intervention. CLEAR characterizes the intervention using two complementary auditing cues: response cues, capturing semantic and clinically meaningful changes in the generated response, and alignment cues, measuring changes in image-phrase compatibility. These cues are normalized and jointly modeled to estimate phrase-level hallucination risk. Across four datasets spanning RRG and Med-VQA, CLEAR outperforms state-of-the-art hallucination detection baselines across multiple medical and general-purpose VLMs. On MIMIC-CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its effectiveness is further validated on a GT-derived controlled VIH benchmark. These results establish visually irrelevant hallucination as an important fine-grained reliability failure mode in medical VLMs and demonstrate the value of model-agnostic visual-support auditing for more trustworthy multimodal clinical generation.

0.06

Robust Detection of Directional Adversarial Attacks in Deep Neural Networks for Radiological Imaging

cs.CV cs.CRcs.LG ·2026-10-11 ·Tristan Malatyński, Joanna Jaworek-Korjakowska
published similarity 0.66
Abstract · Published in CVPR 2026 Workshops (SAIAD); open access: https://openaccess.thecvf.com/content/CVPR2026W/SAIAD/html/Malatynski_Robust_Detectio…

Deep learning is now central to radiology, helping detect changes on X-rays, CTs, and MRIs. However, these systems are highly vulnerable to adversarial attacks - small, crafted perturbations that mislead models while appearing unchanged to humans. Such errors risk missed cancers or false positives. Studies show over 90% attack success on medical scans. Almost 30% of US hospitals use AI in imaging in 2023. Thus, an effective method of detecting such attacks and their directionality is crucial to ensure the credibility and reliability of medical systems based on DNNs. We propose a novel detection framework that leverages subsequent attacks using random noise to identify adversarial perturbations. Our approach uses the analysis of variations in the Sigmoid function to distinguish genuine medical images from adversarially manipulated ones. Specifically, we compare prediction differences between clean and attacked images, as well as between different adversarially altered versions, to improve detection accuracy. We evaluated our method on three popular medical datasets including 'Chest X-Ray Images for Classification', 'Retinal Fundus Multi-disease Image Dataset' and 'Brain Tumor Dataset' under various attack scenarios, including random noise. Our framework achieved up to 99.8% ACC in identifying adversarial directional attacks, significantly outperforming existing defense mechanisms. It consistently identified adversarial samples across varying attack strengths while keeping false positives low, showing strong reliability and potential for clinical use. Furthermore, our proposal highlights its potential for real-world deployment.

0.40

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.66
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.53

Text-Guided Diffusion-Based Adversarial Attacks on Chest X-Ray Images

cs.CV ·2026-08-29 ·Basudha Pal, Arjun Narayanan, Neha Ajith, Vikas R Bhat, Muhammad Umair
similarity 0.64
Abstract

As artificial intelligence is increasingly integrated into chest X-ray (CXR) interpretation, triage, and clinical decision support, understanding its vulnerability to adversarial manipulation is critical for safe deployment. Existing robustness evaluations, however, predominantly rely on pixel-space attacks that introduce numerically constrained perturbations but may not represent plausible radiographic variation. This limitation is particularly important in multi-disease CXR classification, where models simultaneously evaluate multiple overlapping pathologies and adversarial failures may alter several diagnostic predictions. We propose a text-guided diffusion-based adversarial framework that optimizes learnable text conditioning while keeping the diffusion generator and target classifier frozen, enabling adversarial generation through a learned image prior rather than direct pixel manipulation. We evaluate the framework across multiple classifier architectures in both binary atelectasis and multi-disease CXR classification and compare it with FGSM, PGD, and Carlini-Wagner attacks. Our approach consistently produced the greatest degradation in classifier performance, reducing AUROC to 0.3885-0.5646 in binary classification and 0.4441-0.4878 in the multi-disease setting, while achieving superior image fidelity (SSIM 0.9080, LPIPS 0.1670, FID 51.23). Importantly, clinician interpretation remained unchanged for 95.9% of binary and 73.8% of multi-disease adversarial images despite substantial changes in model predictions. These findings reveal a clinically important discrepancy between human and machine interpretation and demonstrate the need to extend medical AI robustness evaluation beyond conventional pixel-space attacks toward generative threat models that can expose failures under visually and clinically plausible image variations.

0.14

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.64
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

cs.CV ·2026-10-15 ·Shrish Shrinath Vaidya, Gowthamaan Palani, Minmini Selvam, Gokulraja Srinivasaraja, Ganapathy Krishnamurthi
published similarity 0.63
Abstract · The paper has been accepted at ECCV BISCUIT Workshop, 2026

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.