CS Paper Radar

Robust Detection of Directional Adversarial Attacks in Deep Neural Networks for Radiological Imaging

Tristan Malatyński, Joanna Jaworek-Korjakowska

cs.CV cs.CRcs.LG ·submitted 2026-10-11 13:58 UTC · v1
published

Abstract

Deep learning is now central to radiology, helping detect changes on X-rays, CTs, and MRIs. However, these systems are highly vulnerable to adversarial attacks - small, crafted perturbations that mislead models while appearing unchanged to humans. Such errors risk missed cancers or false positives. Studies show over 90% attack success on medical scans. Almost 30% of US hospitals use AI in imaging in 2023. Thus, an effective method of detecting such attacks and their directionality is crucial to ensure the credibility and reliability of medical systems based on DNNs. We propose a novel detection framework that leverages subsequent attacks using random noise to identify adversarial perturbations. Our approach uses the analysis of variations in the Sigmoid function to distinguish genuine medical images from adversarially manipulated ones. Specifically, we compare prediction differences between clean and attacked images, as well as between different adversarially altered versions, to improve detection accuracy. We evaluated our method on three popular medical datasets including 'Chest X-Ray Images for Classification', 'Retinal Fundus Multi-disease Image Dataset' and 'Brain Tumor Dataset' under various attack scenarios, including random noise. Our framework achieved up to 99.8% ACC in identifying adversarial directional attacks, significantly outperforming existing defense mechanisms. It consistently identified adversarial samples across varying attack strengths while keeping false positives low, showing strong reliability and potential for clinical use. Furthermore, our proposal highlights its potential for real-world deployment.

Comment
Published in CVPR 2026 Workshops (SAIAD); open access: https://openaccess.thecvf.com/content/CVPR2026W/SAIAD/html/Malatynski_Robust_Detection_of_Directional_Adversarial_Attacks_in_Deep_Neural_Networks_CVPRW_2026_paper.html

Closest papers

Nearest neighbours by meaning across the whole index.

Text-Guided Diffusion-Based Adversarial Attacks on Chest X-Ray Images

cs.CV ·2026-08-29 ·Basudha Pal, Arjun Narayanan, Neha Ajith, Vikas R Bhat, Muhammad Umair
similarity 0.71
Abstract

As artificial intelligence is increasingly integrated into chest X-ray (CXR) interpretation, triage, and clinical decision support, understanding its vulnerability to adversarial manipulation is critical for safe deployment. Existing robustness evaluations, however, predominantly rely on pixel-space attacks that introduce numerically constrained perturbations but may not represent plausible radiographic variation. This limitation is particularly important in multi-disease CXR classification, where models simultaneously evaluate multiple overlapping pathologies and adversarial failures may alter several diagnostic predictions. We propose a text-guided diffusion-based adversarial framework that optimizes learnable text conditioning while keeping the diffusion generator and target classifier frozen, enabling adversarial generation through a learned image prior rather than direct pixel manipulation. We evaluate the framework across multiple classifier architectures in both binary atelectasis and multi-disease CXR classification and compare it with FGSM, PGD, and Carlini-Wagner attacks. Our approach consistently produced the greatest degradation in classifier performance, reducing AUROC to 0.3885-0.5646 in binary classification and 0.4441-0.4878 in the multi-disease setting, while achieving superior image fidelity (SSIM 0.9080, LPIPS 0.1670, FID 51.23). Importantly, clinician interpretation remained unchanged for 95.9% of binary and 73.8% of multi-disease adversarial images despite substantial changes in model predictions. These findings reveal a clinically important discrepancy between human and machine interpretation and demonstrate the need to extend medical AI robustness evaluation beyond conventional pixel-space attacks toward generative threat models that can expose failures under visually and clinically plausible image variations.

0.14

Fusing Spectral Signatures and Activation Clustering for Backdoor Detection in Healthcare Imaging Models: Method, Implementation, and Evaluation

cs.CR cs.LG ·2026-09-13 ·Suresh Tamang
benchmarkcode/data similarity 0.69
Abstract · 13 pages, 2 figures, 3 tables. Implementation available at https://github.com/tsurace37/aegis-scan . Also deposited at Zenodo, doi:10.5281/z…

Machine learning models are increasingly deployed in healthcare imaging pipelines for diagnostic support, and training-time attacks against them are a named sector-level concern: healthcare-sector guidance identifies model poisoning and adversarial attacks as threats requiring dedicated defenses, while federal policy directs expanded AI vulnerability-detection tooling to critical infrastructure operators such as rural hospitals. Spectral signature analysis and activation clustering are two established backdoor detection methods routinely evaluated as independent baselines, but their outputs are not ordinarily combined, and reported detection performance on medical imaging benchmarks remains sparse relative to the natural-image setting. This paper contributes three things: a score-level fusion rule combining per-class spectral ranking with activation-clustering flags into a single per-sample poisoning score and a model-level agreement statistic; an open-source implementation of the resulting eight-stage pipeline; and an evaluation of that pipeline against synthetically poisoned variants of a public medical imaging benchmark and CIFAR-10 at four poisoning rates (0%, 1%, 5%, 10%) over five seeds each, measuring each detector alone against the fusion. On the medical benchmark, the fused detector reaches AUROC >= 0.99 at every nonzero poisoning rate tested. On CIFAR-10, fusion does not uniformly help: at 10% poisoning, activation clustering's true-positive rate collapses to 0.000 and spectral AUROC independently degrades to near-chance (0.545), despite a 97.2% attack success rate confirming the backdoor was fully installed. The fused score, a weighted combination of both signals, inherits this joint failure. Detection output is expressed in NIST AI RMF Measure-function and MITRE ATLAS terms, so findings are reported in the vocabulary security and compliance teams already use.

0.45

Interpretable Deep Learning Models for Breast Cancer Diagnosis Using Medical Imaging

cs.CV cs.AI ·2026-10-27 ·Sami Alnawali, Muhammad Atif Saeed, Abdul Hadi, Azka Atiq, Akhtar Jamil +1 more
benchmark similarity 0.68
Abstract · 37 page, 45 Figures

Deep learning shows promise for breast cancer diagnosis, but limited interpretability hinders clinical adoption. We benchmark ten ImageNet-pretrained models (ResNet50, VGG19, InceptionV3, DenseNet121, Xception, MobileNetV2, EfficientNet, ConvNeXt, ViT, and Swin Transformer) for benign-versus-malignant classification on the BreakHis histopathology dataset using a patient-level split, and explain their predictions with Grad-CAM, LIME, Integrated Gradients, and LRP. DenseNet121 performed best, with 99.4% test accuracy and an AUC-ROC of 0.999, and significantly outperformed all other models (p < 0.001). Transformer-based models trailed the CNNs. The explanations consistently highlighted nuclei-rich and glandular regions of diagnostic relevance. Combining transfer learning with explainable AI can thus yield accurate, interpretable tools for breast cancer diagnosis.

0.19

SpurCon: Weighted Supervised Contrastive Learning for Mitigating Spurious Cues in Medical Imaging

cs.CV ·2026-08-18 ·Shenhav Nadir, Meir Yossef Levi, Eyal Gofer, Guy Gilboa
similarity 0.67
Abstract

Despite the rapid progress of deep neural networks in visual recognition, their adoption in high-risk medical applications remains limited due to reliability and robustness concerns. Models may exploit spurious correlations, particularly in medical imaging, where devices or treatment artifacts often co-occur with pathology. In small or imbalanced datasets, such cues further reduce worst-group performance and undermine clinical trust. To solve these issues, two major challenges should be addressed: identifying dataset-specific spurious cues, which typically require domain knowledge, and mitigating reliance on them. To tackle both, we propose SpurCon, a lightweight framework based on a novel supervised contrastive loss formulation that leverages available metadata and predicted spurious labels to enhance robustness. We introduce a fast few-shot procedure, without network training, to estimate spurious labels using a small number of expert-annotated samples. We then propose a weighted supervised contrastive objective, WtSupCon, that reshapes the representation geometry by assigning sample-specific weights that depend on the [pathology, spurious, metadata] combination. For example, the highest weight is assigned to samples that differ only in their spurious label. This yields highly similar representations for images with the same metadata and pathology, differing only in the predicted spurious label. Our method operates on pretrained image encoders (such as BiomedCLIP) and trains only a lightweight projection head. We evaluate SpurCon on a synthetic setting and on Waterbirds, CheXpert, a chest X-ray classification dataset, and ISIC 2020, a skin cancer classification dataset. Our approach delivers the best spurious-mitigation performance, balancing well worst-group and overall accuracy on multiple datasets.

0.16

A Comparative Study of GAN-Based Deep Learning Models for Pneumonia Detection in Chest X-Rays

cs.CV ·2026-09-05 ·Roshan Paudel, Aashish Ghimire, Pramod Acharya
similarity 0.66
Abstract

This study evaluates pneumonia classification in chest X-rays using VGG19, MobileNetV2, ResNet50, and a custom CNN, and explores Generative Adversarial Network (GAN)-based synthetic data augmentation. MobileNetV2 achieved the highest reported accuracy of 88% with balanced class-wise performance. The custom CNN achieved pneumonia recall of 92.67% and precision of 79.43%, highlighting a precision-recall trade-off. Accuracy, F1-score, precision, recall, confusion matrices, and training curves were used to assess performance. Synthetic pneumonia images were combined with real images to investigate whether augmentation could improve classification performance. In the reported VGG19 comparison, augmented-data training accuracy reached approximately 100%, while validation accuracy remained near 50%, below the real-data validation accuracy. This experiment therefore did not demonstrate a validation-performance benefit from GAN augmentation. The classifier comparison highlights differences in accuracy and pneumonia recall, while the augmentation experiment indicates the need for further evaluation of synthetic-image quality and training settings.

0.26

Adversarial Evaluation of Large Language Models for Patient-Friendly Radiology Report Summarization

cs.AI ·2026-11-06 ·Magdalini Paschali, Asad Aali, Arogya Koirala, Andrew Johnston, Katherine McNamara +4 more
similarity 0.66
Abstract · This work has been submitted to Radiology: Artificial Intelligence for possible publication. Copyright may be transferred without notice, af…

Purpose: To develop and validate a scalable adversarial evaluation framework for assessing the robustness of large language models (LLMs) that generate patient-friendly summaries of radiology reports. Methods: We introduced a clinically grounded adversarial framework that uses controlled term substitutions and impression removals across intensity levels. Using a radiologist-validated adversarial dictionary, we generated adversarial variants of CT and MRI reports. Six LLMs summarized original and adversarial impressions using 2 prompt styles, yielding 18,000 evaluation pairs. Robustness was evaluated with an automated LLM-as-a-judge framework scoring factual faithfulness, sensitivity to adversarial edits, certainty fidelity, and hallucination rate. Failure mode analysis quantified vulnerabilities in incorporating clinical modifiers. Agreement with two radiologists was assessed on 105 cases. Results: GPT-5-mini achieved the highest factual faithfulness and certainty fidelity under both adversarial edits. Under term substitution, hallucinations occurred in 28.1-30.1% of GPT-5-mini summaries, compared with 35.3-36.4% for Claude Sonnet 4.5 and 41.4-41.9% for MedGemma. Impression-removal edits were handled more robustly than term substitutions. Even for the highest-scoring summarizer, substitutions of anatomical terms were not reflected in 23.7% of summaries, diagnostic certainty in 22.3%, and descriptor terms (e.g., "substantial") in 21.2%. Judge-radiologist agreement (macro-F1: 0.55-0.56) was comparable to inter-radiologist agreement (0.53). Conclusions: Adversarial evaluation exposes clinically meaningful failure modes, including missed anatomical modifiers, altered diagnostic certainty, and omitted severity descriptors.

0.18

Training-Free Reconstruction-Based AI-Generated Image Detectors Are Inherently Vulnerable to Adversarial Examples

cs.CV ·2026-08-17 ·Roman Demchenko, Jonas Ricker, Asja Fischer
published similarity 0.66
Abstract · Accepted at AI4MFDD (AI for Multimedia Forensics & Disinformation Detection) Workshop, ECCV 2026

The impressive visual quality and ubiquity of AI-generated images call for reliable and robust detection methods. Reconstruction-based detectors have emerged as a promising direction for transparent and training-free identification of synthetic images. However, due to their fundamentally different mode of operation (compared to standard, classifier-based methods), little is known about their adversarial robustness. In this work, we propose two novel attack methods targeted at detectors that leverage autoencoder reconstruction error. We find that by constructing imperceptible adversarial examples, the distance between original and reconstruction can be artificially increased, causing fake images to be wrongly classified as real. Our evaluation including images from three state-of-the-art generators and three detectors demonstrates that detection performance is significantly decreased, even if attacked images additionally undergo real-world degradations. Critically, our adversarial examples naturally transfer across detectors, as they all share the same principle, pointing towards an inherent vulnerability of reconstruction-based detectors.

0.20

High-Capacity Robust Medical Image Exfiltration via Neural Network Weight Replacement

cs.CV cs.AIcs.CR ·2026-09-22 ·Elie Thellier, Huiyu Li, Nicholas Ayache, Hervé Delingette
top venuecode/data similarity 0.65
Abstract

Collaborative medical AI platforms allow researchers to train models on sensitive imaging data while restricting data export. However, trained models can serve as covert carriers of patient information: medical images may be encoded within model parameters and reconstructed outside the secure environment. Existing defenses rely on lightweight sanitization (e.g., fine-tuning, pruning, quantization) and limited statistical auditing, creating a realistic insider exfiltration risk. We introduce a high-capacity neural steganography attack that encodes medical images as continuous latent representations embedded into model initialization. A StyleGAN2-based adversarial autoencoder learns compact latent codes regularized to match standard weight initialization statistics, keeping embedded parameters statistically consistent with clean models. Noise injection during training improves robustness to export-time mitigation. The carrier model remains functional on its intended task and hidden images can be reconstructed directly from its weights after export. This continuous encoding enables robust and scalable exfiltration, allowing up to 99 brain MRI volumes to be embedded within a 30MB model, and remains recoverable under mitigations that disrupt prior bit-level schemes. While reconstructions are approximate rather than pixel-exact, embedded content remains anatomically recognizable and recoverable at scale, exposing a privacy risk distinct from prior bit-level approaches. Experiments on MIMIC-CXR, BraTS, and LiTS demonstrate effectiveness across modalities, tasks, and architectures, highlighting the need for structural defenses beyond parameter-level sanitization. Code is available at https://github.com/ElieThellier/high-capacity-robust-medical-image-exfiltration.

0.54