CS Paper Radar

Corpus Characterization and Inverse Constitutional Fine-Tuning for Style-Aware Radiology Reports

Sarah Y. Li, Elijah Renner, Rayan Ansari, Alaa Youssef

cs.CL ·submitted 2026-09-13 01:40 UTC · v1

Abstract

Automated radiology report generation has advanced rapidly in diagnostic accuracy, yet generated reports frequently diverge from the stylistic conventions of authentic radiologist writing in structure, diction, and uncertainty language, a gap which has direct implications for clinician trust and user experience. To address this, we characterize stylistic variation across 2,000 reports from the CheXpert Plus dataset using Bio-ClinicalBERT embeddings, UMAP dimensionality reduction, and HDBSCAN clustering, identifying five distinct reporting patterns differing in pathology focus, narrative structure, and lexical preference. Drawing on these findings, we adapt the inverse constitutional AI framework to derive a style-focused constitution from radiologist-written report pairs without requiring a formal preference dataset. This constitution, encoding conventions of tone, diction, uncertainty calibration, and report structure, is incorporated into the supervised fine-tuning of a MedGemma-4B base model on 25,245 CheXpert Plus training pairs. Constitutional fine-tuning produces a substantial increases in text alignment (BLEU-4: 0.006 to 0.308; ROUGE-L: 0.171 to 0.484) relative to the untuned baseline. These gains show a qualitative shift in structural and lexical alignment rather than marginal improvement, as the baseline model produces near-zero scores due to format mismatch. Overall, we establish corpus-level style characterization and constitutional modeling as an effective and data-efficient strategy for producing radiology reports that conform to authentic radiologist writing conventions.

Closest papers

Nearest neighbours by meaning across the whole index.

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

cs.LG ·2026-11-06 ·Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner +3 more
similarity 0.68
Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

0.21

templar: agentic induction and evolution of standardized radiology reporting templates from large-scale clinical corpora

cs.MA cs.CL ·2026-10-04 ·Xiaotian Hu, Mingxuan Liu, Zhonghan Wang, Xinfeng Zhang, Yiming Huang +7 more
similarity 0.66
Abstract

Structured radiology reporting mitigates the heterogeneity of free-text reports, yet its benefits depend on high-quality reporting templates. In practice, such templates are conventionally built through labor-intensive expert consensus and therefore vary across institutions and lag behind evolving clinical practice. Large language models (LLMs) enable automated template induction, but existing approaches remain limited: single-LLM induction is constrained by context length, and the corpus-scale method ASTAR produces a static, closed-corpus template without external grounding or downstream adaptation. To address these limitations, we propose TEMPLAR, a TEMPLate-centric Agentic framework for inducing and evolving standardized Radiology reporting templates from large-scale clinical corpora. TEMPLAR treats the template as a persistent central state maintained alongside two provenance-aware knowledge graphs, namely an anatomical graph that constrains template construction and a diagnostic graph that supports finding-to-diagnosis reasoning. Three agents operate on this state. The Induction Agent derives canonical clinical slots from anatomy-constrained Span-Triple atoms via dual-view similarity clustering; the Evolution Agent then assembles these slots into a hierarchical template and revises it under consistency constraints, external clinical evidence, and downstream structuring feedback; and the Clinical Agent applies the evolved template to report structuring, reconstruction, and diagnostic reasoning. Across four datasets, TEMPLAR outperforms ASTAR, three medical LLMs, and six general-purpose LLMs in coverage, information fidelity, and diagnostic fidelity, while achieving the highest or tied-highest LLM-rated template quality. Its fidelity advantages over ASTAR persist under cross-dataset transfer, and cumulative ablations support complementary contributions of its key components.

0.10

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.63
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.17

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.63
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

Improving Health Literacy through Lay Summarization of Radiological Reports: An Evaluation of BioNER and Retrieval-Augmented Generation

cs.CL ·2026-09-02 ·Egecan Çelik Evgin, İlknur Karadeniz, Olcay Taner Yıldız
similarity 0.62
Abstract

Radiology reports are written primarily for clinicians, and their specialized terminology often makes them difficult for patients to interpret. As a result, many patients turn to publicly available Large Language Models (LLMs) to help explain their reports, despite well-documented risks of factual inaccuracies and hallucinations. Automated lay-summary generation has emerged as a promising alternative, yet the effectiveness of retrieval-enhanced and clinically informed approaches for radiology-specific communication remains underexplored. This study investigates the extent to which Retrieval-Augmented Generation (RAG) and Named Entity Recognition (NER) improve the quality, factual consistency, and readability of automatically generated lay summaries compared with standard LLM-based generation. We develop a framework combining NER-based extraction of clinically relevant findings with a RAG mechanism for contextual grounding, evaluated across few-shot and fine-tuned variants of two models (Qwen, BioBART). Results show that NER consistently improves readability and overall quality, while RAG alone offers no benefit and can introduce hallucinations from irrelevant retrieved terms. Combining RAG with NER degrades performance in few-shot settings but improves readability when fine-tuned. Fine-tuned BioBART with NER achieves the best overall performance, highlighting entity-aware extraction as the primary driver of improved patient-friendly summaries.

0.23

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

cs.AI cs.CL ·2026-10-03 ·Friedrich Puttkammer, Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf +17 more
similarity 0.62
Abstract · 27 pages, 9 figures

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

0.19

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.61
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.53

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.61
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60