CS Paper Radar

Toward Better Assessment of LLMs' Performance in Clinical Error Detection

Yifan Zhang, Rahmatollah Beheshti

cs.CL cs.AIcs.LG ·submitted 2026-08-17 14:41 UTC · v1
top venuebenchmarkcode/data

Abstract

Automated detection of errors in clinical documentation is a promising application of large language models (LLMs), yet decisions to deploy such models rest on benchmarks that evaluate each clinical note in isolation. Error-detection benchmarks are typically constructed by injecting errors into notes, such that each erroneous note has a natural counterpart. Aggregate discriminative metrics (e.g., balanced accuracy or F1) do not exploit this structure. We show that this omission is consequential. In particular, evaluating 15 diverse LLMs on 4 standardized clinical error-detection test sets across 3 languages, we find that 13 of 15 models fall below the level of random pairwise discrimination, even while achieving F1 scores that standard practice would read as moderate. We also observe that the underlying bias patterns differ across languages: the same model can default to "no error" on one language and over-flag errors on another. To diagnose where discrimination breaks down, we further introduce a procedure to score the evidence models cite in their outputs. We find that while models consistently locate error-relevant content, they fail to produce the corresponding correct verdict on the clean counterpart. Finally, we show that F1 and pairwise accuracy are driven in opposite directions by the same underlying bias, so that ranking models by F1 may systematically promote the weakest discriminators. For safety-critical clinical NLP applications, we advocate for supplementing aggregate metrics with paired evaluations in benchmark reporting. Code and analysis scripts are available at https://github.com/healthylaife/paired-clinical-eval.

Comment
Accepted at Machine Learning for Healthcare (MLHC) 2026; to appear in Proceedings of Machine Learning Research (PMLR), Vol. 340

Closest papers

Nearest neighbours by meaning across the whole index.

Making Clinical Language Models Auditable: Concept-Guided Fine-Tuning for Robust Prediction

cs.CL cs.AI ·2026-08-27 ·Jin Mu, Guanhua Chen
top venue similarity 0.69
Abstract

Clinical language models can achieve strong in-hospital accuracy yet fail under deployment shifts because they exploit note-specific artifacts (e.g., templates, separators, boilerplate) that do not reflect patient state. We propose CAST (Concept-guided Artifact Suppression Tuning), an SAE-based framework for auditable clinical text classification. CAST uses Sparse Autoencoders to expose sparse, human-auditable features from intermediate Transformer activations, labels SAE latents with an LLM-assisted interpretation pipeline and ICD-10 retrieval constraints, suppresses verified artifact latents via residual subtraction during fine-tuning, and provides post-hoc per-concept attributions for auditing model decisions. On MIMIC-IV discharge-note mortality prediction, CAST improves over its corresponding fine-tuned encoder baselines and remains competitive with strong LLM baselines, while producing a feature-level audit trail of the clinical concepts that support each prediction and the artifact concepts suppressed during training.

0.44

Error Detection for PET/CT Radiology Reports: Domain-Specific vs Large Language Models

cs.LG cs.AI ·2026-08-30 ·Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan +1 more
benchmark similarity 0.68
Abstract

Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.

0.25

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.66
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

Auditing evaluation artifacts and data leakage in large language model systems for rare disease diagnosis

cs.AI ·2026-10-24 ·Jian Yang, Peilin Liu, Xiaohan Li, Songda Li, Yu Cao +2 more
benchmark similarity 0.66
Abstract · 18 page, 3 figures

Augmented large language model (LLM) systems have reported high benchmark accuracies in rare disease diagnosis, yet their real-world clinical utility remains unproven. A recent meta-analysis flagged augmented LLM diagnostic evaluations as having a high risk of bias due to suspected data leakage; however, the precise impact of these vulnerabilities on model inference has yet to be fully quantified. In this study, we present a comprehensive empirical audit to quantify evaluation artifacts across prevailing AI paradigms, using a repository of over 60,000 cases from diverse public and independent clinical cohorts. By reconstructing a state-of-the-art agentic framework, we demonstrate that candidate-space contamination artificially inflates performance: enforcing strict cross-dataset isolation resulted in a marked performance decline, with the cross-dataset mean Recall@1 decreasing from 54.3% (under conventional one-vs-rest evaluation) to 40.3% (Hedges' g = 0.94). Similar spatial overfitting in supervised classifiers caused diagnostic accuracy to drop from an internal mean of 42.9% to 16.7% across external cohorts (Cohen's d = 2.01). Furthermore, we quantify how LLMs infer diagnoses by exploiting retrospective therapeutic cues in clinical narratives, and how temporal misalignment in foundational knowledge bases leads to performance fluctuations. We conclude that prevailing evaluation protocols for augmented LLM systems inadvertently reflect data leakage rather than genuine medical reasoning. To address these systematic artifacts, we propose a rigorous evaluation framework - coupling strict data-isolation protocols with standardized benchmarking safeguards - to ensure future diagnostic AI for rare diseases is evaluated on actual clinical robustness.

0.50

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.66
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

What Proves You Wrong: Benchmarking Language Models on Falsifiable Research Ideation

cs.CL cs.AI ·2026-08-24 ·Ziyue Wang, Aomufei Yuan, Yiran Yao, Linli Yao, Hongyao Zuo +8 more
benchmark similarity 0.66
Abstract · Equal contribution by Ziyue Wang, Aomufei Yuan and Yiran Yao. Corresponding authors: Tong Yang and Xu Sun

Large language models are increasingly used to propose research ideas, yet the prevailing ways of judging such ideas supply no shared decision rule: free-form judging sways with style and position, and scoring against a later paper rewards recovery of one realized trajectory. We introduce a benchmark that carries a proposal from Literature to Test: the Lit2Test benchmark centers on a six-field contract organized around a falsifying outcome, so that every proposal precommits the observation that would prove it wrong, making its quality decidable in the first place rather than merely arguable. Built prospectively from 200 real-paper neighborhoods, Lit2Test elicits proposals from four frontier models and compares them through 1,200 pairwise comparisons judged blind in both presentation orders. The protocol audits its own reliability through diagnostic controls and bounded human calibration, with three annotators corroborating the conclusions within explicitly stated reliability bounds. Lit2Test recovers a strict ranking of the four models in all 10,000 bootstrap replicates, and the separation comes from the quality of the proposed tests and metrics rather than from surface fluency. We release the benchmark, construction pipeline, and audit artifacts for public use.

0.48

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.66
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

SynthSentry: Detecting Synthetic Data Contamination in Language Model Training Data

cs.CL ·2026-09-11 ·Praveen Kumar Myakala, Ravichandra Namburi, Sowmya Keragodu Jayaramu, Sooraj George Thomas
similarity 0.65
Abstract · 11 pages, 3 Figures, 2026 IEEE Asia Conference on Innovation in Emerging Technology

Large language models trained recursively on their own or other models' outputs undergo model collapse, in which distributional tails and factual accuracy deteriorate while fluency survives. Prior work diagnoses collapse after training; the actionable problem is screening a corpus of unknown provenance before training. We introduce SynthSentry, a corpus-level, model-agnostic contamination signal requiring no access to the generating model, no generation history, and no synthetic labels. The score is a distributional divergence over three statistics: lexical diversity collapse, n-gram tail truncation, and perplexity variance across reference models. We evaluate on corpora contaminated by small open-weight generators and an instruction-tuned open-weight model under a leave-one-generator-out protocol. A domain-stratified study measures false positives on naturally repetitive human text (legal, clinical, source code). The score ranks corpora by severity with little loss when whole generator families are held out. Per-domain calibration holds near its nominal false-positive budget once covariance shrinkage and a bootstrap threshold replace a naive quantile, which runs four times over budget. A downstream fine-tuning check showed no contamination-driven accuracy deficit at our scale, so whether pruning recovers one remains open; the same run shows over-pruning risk once pruning exceeds the true contamination fraction. We frame screening as a data-curation defense rather than a post-hoc diagnosis and release the scoring toolkit. All results are small-scale; scope is English-language, batch-mode corpus screening. Contamination sources are single-generation or hand-authored rather than recursively generated, so results speak to synthetic contamination generally and not to recursion depth.

0.31