CS Paper Radar

Clinical Reasoning Under a Partially Observed Objective in Cone Beam CT Report Generation

Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan

cs.CL cs.CV ·submitted 2026-09-02 15:06 UTC · v1
code/data

Abstract

Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large language model judgement of factual entailment and 20% on lexical overlap, of which only the lexical fifth is visible during development. The grader's BLEU-4 and METEOR routines are reproduced in pure Python and match the reference to machine precision, and an offline entailment surrogate, which tells a report written for one patient from one written for another at an area under the curve of 0.987, makes the composite objective cheap enough to optimise directly. Over the 622-case public release, a report selected against the visible lexical ranking scores 0.2909, whereas one selected against the composite objective scores 0.4122, because pursuing n-gram overlap drives entailment precision from 0.522 down to 0.266. A 29 million parameter encoder fine-tuned on the release reaches a prevalence-weighted out-of-fold area under the curve of 0.486 over 985 statements, indistinguishable from the corpus prior, while nine numbers read from the image header reach 0.945 for mandible coverage and 0.872 for condyle coverage, and acquisition centre alone predicts sentence choice at 0.718 against 0.663 for the image-derived model, identifying dictation convention rather than anatomy as the quantity the lexical metrics reward. The delivered system emits eight unconditional statements and five gated on header geometry under polarity, laterality and tooth-level consistency constraints, and reaches METEOR 0.3542 over 50 held-out cases from an unseen centre. The dataset and code are available at https://github.com/GIND123/CBCT-Clinical-Reasoner

Comment
11 pages, 3 figures. ODIN 2026 CBCT report generation challenge system. Code: https://github.com/GIND123/CBCT-Clinical-Reasoner

Closest papers

Nearest neighbours by meaning across the whole index.

EviGround-CT: Sentence-to-Volume Grounding for Verifying LLM-Generated Chest CT Reports

cs.CL cs.CVcs.LG ·2026-10-15 ·Ziyuan Li, Juncheng Ni, Feng Li
published similarity 0.64
Abstract · Accepted at IEEE BIBM 2026

Chest computed tomography (CT) reports generated by large language models (LLMs) can describe positive findings that lack localized evidence in the scan. We propose EviGround-CT to verify these findings after report generation. A deterministic extractor identifies positive finding sentences, and a 3D grounding model predicts an evidence mask for each sentence. Using the full sentence retains anatomical location, laterality, and descriptive modifiers in the grounding query. We evaluate report generation on CT-RATE, and grounding and verification on a held-out 100-case ReXGroundingCT subset. Using the available annotations, sentence-grounded verification raises evidence-supported precision (ESP) from 0.263 to 0.365 across 137 extracted in-scope positives, compared with category conditioning. The corresponding unsupported positive finding rate falls from 0.737 to 0.635. The paired case-level bootstrap ESP difference is +0.102 (95% confidence interval: [0.028, 0.181]). The predicted masks associate individual report statements with spatial evidence that can be inspected alongside the CT.

0.23

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.64
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.61
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52

Can large language models unlock discrete data in ophthalmic diagnostic reports?

cs.CL ·2026-09-30 ·Umair A. Zaidi, An-Lun Wu, Wei-Chun Lin, Thomas S. Hwang, Michelle R. Hribar
published similarity 0.60
Abstract · 10 pages, 5 figures. Presented at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting, Denver, Colorado, May 4, 2…

Objective: To assess the accuracy and efficiency of a large language model (LLM) using two prompt strategies to extract structured data from ophthalmic diagnostic PDF reports. Methods: Twenty deidentified reports across four types (Visual Field, OCT Glaucoma Overview, OCT retinal nerve fiber layer Single Exam, and OCT Thickness Map; n = 5 each) were processed using two GPT-4o-assisted pipelines and compared with a reconciled manual ground truth. Schema-Constrained used Structured Output mode with a predefined JSON Schema; Prompt-Only used a detailed instruction prompt followed by Python conversion to JSON. Outcomes were value accuracy, formatting accuracy, and extraction time. Results: Schema-Constrained value accuracy was 100.00% for Visual Field and RNFL Single Exam, 97.45% for Glaucoma Overview, and 98.00% for Thickness Map; Prompt-Only achieved 100.00% across all four report types. Formatting accuracy was 100.00% for Schema-Constrained across all report types and 100.00% for Prompt-Only except RNFL Single Exam (90.14%). Mean extraction time was 56.51 s per report for manual review versus 5.04 s for Schema-Constrained and 4.70 s for Prompt-Only, an approximately 92% reduction. Conclusions: In this small proof-of-concept dataset, general-purpose LLM-assisted pipelines extracted structured data from ophthalmic diagnostic PDFs with high accuracy and substantially reduced processing time. Prompt-Only achieved the highest value accuracy, while Schema-Constrained produced schema-compliant output with 100% formatting accuracy. These complementary strengths support further evaluation of hybrid, validation-aware workflows for research and clinical data abstraction.

0.40

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.60
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

Evidence First, Arithmetic Second: A System Report and Failure Analysis for DocSem

cs.CL cs.IR ·2026-09-30 ·Divya Godara, Sachin Gupta
similarity 0.59
Abstract · 5 pages, 1 figure, 2 tables. Accepted as a shared-task system paper at DocInsights 2026, co-located with EMNLP 2026

EVICALC, our system for the DocSem shared task, achieved 8.61% joint accuracy on 1,730 tasks in the official final test evaluation. It reads a PDF, selects a passage, asks a language model to write an arithmetic expression, and evaluates that expression in local code. Saved intermediate results support inspection of failures. A separate public-validation run achieved 92.17% answer accuracy and 1.00 evidence F1. The configurations and metrics differ, so these scores are not a controlled comparison. Our manual, post-hoc analysis is descriptive: in one inspected case, optical character recognition (OCR) and block grouping merged the relevant passage into another block, and the system answered from unrelated text. An exploratory study of reading page images on 100 documents returned evidence identifiers for only 22 documents. These descriptive findings motivate further evaluation; they do not establish the causes of the overall score.

0.37

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.59
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

cs.AI cs.CL ·2026-10-03 ·Friedrich Puttkammer, Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf +17 more
similarity 0.58
Abstract · 27 pages, 9 figures

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

0.19