CS Paper Radar

Can large language models unlock discrete data in ophthalmic diagnostic reports?

Umair A. Zaidi, An-Lun Wu, Wei-Chun Lin, Thomas S. Hwang, Michelle R. Hribar

cs.CL ·submitted 2026-09-30 22:35 UTC · v1
published

Abstract

Objective: To assess the accuracy and efficiency of a large language model (LLM) using two prompt strategies to extract structured data from ophthalmic diagnostic PDF reports. Methods: Twenty deidentified reports across four types (Visual Field, OCT Glaucoma Overview, OCT retinal nerve fiber layer Single Exam, and OCT Thickness Map; n = 5 each) were processed using two GPT-4o-assisted pipelines and compared with a reconciled manual ground truth. Schema-Constrained used Structured Output mode with a predefined JSON Schema; Prompt-Only used a detailed instruction prompt followed by Python conversion to JSON. Outcomes were value accuracy, formatting accuracy, and extraction time. Results: Schema-Constrained value accuracy was 100.00% for Visual Field and RNFL Single Exam, 97.45% for Glaucoma Overview, and 98.00% for Thickness Map; Prompt-Only achieved 100.00% across all four report types. Formatting accuracy was 100.00% for Schema-Constrained across all report types and 100.00% for Prompt-Only except RNFL Single Exam (90.14%). Mean extraction time was 56.51 s per report for manual review versus 5.04 s for Schema-Constrained and 4.70 s for Prompt-Only, an approximately 92% reduction. Conclusions: In this small proof-of-concept dataset, general-purpose LLM-assisted pipelines extracted structured data from ophthalmic diagnostic PDFs with high accuracy and substantially reduced processing time. Prompt-Only achieved the highest value accuracy, while Schema-Constrained produced schema-compliant output with 100% formatting accuracy. These complementary strengths support further evaluation of hybrid, validation-aware workflows for research and clinical data abstraction.

Comment
10 pages, 5 figures. Presented at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting, Denver, Colorado, May 4, 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.61
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

Clinical Reasoning Under a Partially Observed Objective in Cone Beam CT Report Generation

cs.CL cs.CV ·2026-09-02 ·Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
code/data similarity 0.60
Abstract · 11 pages, 3 figures. ODIN 2026 CBCT report generation challenge system. Code: https://github.com/GIND123/CBCT-Clinical-Reasoner

Maxillofacial report generation from cone beam computed tomography is scored here by a composite objective placing 80% of its weight on a large language model judgement of factual entailment and 20% on lexical overlap, of which only the lexical fifth is visible during development. The grader's BLEU-4 and METEOR routines are reproduced in pure Python and match the reference to machine precision, and an offline entailment surrogate, which tells a report written for one patient from one written for another at an area under the curve of 0.987, makes the composite objective cheap enough to optimise directly. Over the 622-case public release, a report selected against the visible lexical ranking scores 0.2909, whereas one selected against the composite objective scores 0.4122, because pursuing n-gram overlap drives entailment precision from 0.522 down to 0.266. A 29 million parameter encoder fine-tuned on the release reaches a prevalence-weighted out-of-fold area under the curve of 0.486 over 985 statements, indistinguishable from the corpus prior, while nine numbers read from the image header reach 0.945 for mandible coverage and 0.872 for condyle coverage, and acquisition centre alone predicts sentence choice at 0.718 against 0.663 for the image-derived model, identifying dictation convention rather than anatomy as the quantity the lexical metrics reward. The delivered system emits eight unconditional statements and five gated on header geometry under polarity, laterality and tooth-level consistency constraints, and reaches METEOR 0.3542 over 50 held-out cases from an unseen centre. The dataset and code are available at https://github.com/GIND123/CBCT-Clinical-Reasoner

0.73

RetiJev: Fast and Source-Grounded Ophthalmic Decision Models

cs.CL cs.AI ·2026-10-22 ·Bo Liu, Lianyu Wang, Meng Wang, Ching-Yu Cheng, Huazhu Fu
benchmarkcode/data similarity 0.59
Abstract

Ophthalmic clinical decision support requires fast, accurate, and privacy-preserving inference, yet autoregressive large language models (LLMs) incur substantial latency and computational overhead for decisions among predefined actions. We therefore investigate a decision-oriented alternative to generative reasoning. Specifically, we first introduce RetiJev-Data, a source-grounded ophthalmology corpus comprising 78,158 clinical-decision and diagnosis questions derived from articles in PubMed Central and a MeSH vocabulary covering 531 eye diseases, and 50,074 guideline-grading questions spanning 11 grading systems, along with a 24,662-question evaluation benchmark. Based on this, we develop RetiJev, a family of 0.8B-9B decision models that directly score candidate answers without autoregressive decoding. Across all model sizes, RetiJev outperforms both a 27B LLM and the commercial Jev 1.13 decision model on guideline grading by 10.4-23.0 points. RetiJev-9B further achieves the highest accuracy on clinical decisions, improving over both baselines by 5.4-6.5 points while matching them on diagnosis. It answers a case in 158 ms on one GPU, 3.5x faster than LLM generation and 470x faster than reasoning. Models are released at https://github.com/Awenbocc/RetiJev.

0.51

Autonomous Structuring of Radiology Reports Across Modalities at Archive Scale Using an Open-Weight Large Language Model

cs.AI cs.CL ·2026-10-03 ·Friedrich Puttkammer, Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf +17 more
similarity 0.59
Abstract · 27 pages, 9 figures

Purpose: To develop and evaluate an open-weight large language model (LLM) pipeline that converts an entire archive of free-text radiology reports into structured reports without human oversight. Materials and Methods: In this retrospective study, a pipeline with 150 hierarchically organized templates was developed at one center and tested at a second center on reports from 2010 to 2025. The open-weight model gpt-oss-120B selects the template in three constrained-decoding steps and fills it on one local graphics processing unit. Template selection was scored against expert labels on 914 randomly sampled reports of five modalities, structuring quality on 920 radiography and CT reports corrected field by field by five residents. The pipeline then processed the complete archive of the second center. Proportions are reported with Wilson 95% confidence intervals (CIs). Results: An optimal template set was selected for 74.4% of reports (680 of 914; 95% CI: 71.5%, 77.1%) and an appropriate set for 82.3% (752 of 914; 95% CI: 79.7%, 84.6%), 87.7% for single-region and 54.1% for multi-region reports. Macro semantic textual similarity between output and corrected reference was 0.95 for radiography and 0.97 for CT, residents left 88.7% of 24,638 fields unchanged, and unsupported content was flagged in 1.0% and 1.5% of reports. Of 2,186,982 archive reports, 96.5% received structured output, 2,401,544 structured reports, at 1,258 reports per hour on one graphics processing unit. Conclusion: An open-weight LLM pipeline structured a complete multimodality report archive without human oversight with high content fidelity. Multi-region reports remained the main source of template errors.

0.19

ReFormBench: Benchmarking the Stability of Response-Conditioned Format Correction in Large Language Models

cs.AI ·2026-10-14 ·Tianxiang Gao, Yahan Li, Chenlu Guo, Diana Inkpen, Yi Chang +1 more
benchmarkcode/datahot direction similarity 0.56
Abstract

Reliable use of large language models requires responses to satisfy formatting requirements across changing instructions. Standard compliance scores do not distinguish preserving a model's observed format from correcting it, or reveal whether that correction holds across variants. We introduce ReFormBench, a benchmark that uses each model's unconstrained response to the same question as its formatting baseline. It links targets by feature and require/forbid mode, evaluating their instantiated requirements across variants. ReFormBench comprises 5,000 difficulty-screened three-constraint test instances derived from 910 source questions and covering 66 formatting features. TCPR measures complete instruction compliance, while EMCR measures individual and joint correction of targets opposed to the annotated baseline state. Across ten models, EMCR ranges from 34.04% to 64.72%, and the highest three-target correction estimate is 50.02%. Compliance and correction scores yield different model rankings and task-level profiles. A prompting experiment on Qwen3.5-9B improves both metrics, and the catalog covers over 95% of extracted instances on four additional models. ReFormBench makes response-conditioned correction across instruction variants a measurable dimension of format following. The code and data are available at https://anonymous.4open.science/r/ReFormBench/.

0.31

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.56
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52

What Language Adds, and at What Cost: Four Controlled Probes of Pathology Vision-Language Models

cs.CV q-bio.QM ·2026-10-19 ·Wenhao Zhang, Zhongliang Zhou, Yi Ping, Zirui Wang, Sheng Li
similarity 0.56
Abstract

Vision--language models (VLMs) promise to make computational pathology queryable and able to draft reports, but how much language adds beyond the vision backbone is unclear, because almost every system is evaluated by its developers on test sets of their own choosing. We grade published evidence by how it was produced and test four claims with controlled probes that reuse released checkpoints and public data, varying one input at a time. Report text adds prognostic signal: adding a frozen embedding of the stage-redacted report to a slide embedding raises the pooled C-index by 0.019 for progression-free interval and by 0.016 for overall survival across 1{,}633 TCGA patients, and restoring the stage statement adds nothing. Prompts add no measurable accuracy at inference: with features and pooling fixed, zero-shot classification is statistically indistinguishable from a supervised linear probe for lung and renal cancer subtyping. Slide-level question answering is barely grounded: SlideChat answers 74.82\% of SlideBench-VQA(TCGA) items correctly with the slide and 74.41\% without it, whereas its language backbone alone reaches 43.52\%. Paraphrasing leaves accuracy unchanged but flips 8--23\% of answers. Self-reported gains from agentic navigation and few-shot language priors cannot yet be attributed to language. Language thus adds real but narrow value, and we propose minimum controls that would expose these failure modes in future evaluations.

0.18

Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

cs.CL cs.AIcs.LG ·2026-11-15 ·Indranil Mallick, Paromita Roy
similarity 0.56
Abstract · 22 pages, 7 figures

Decision models are a new class of language model that, instead of generating text, choose one option per question from a fixed list and return a probability for every option. They have not yet been evaluated on clinical text. We evaluated two open-weights decision models, Nimble 9B and Tev1 4B, for extracting 25 fields from 1,113 oral cavity cancer pathology reports from a single centre, against a prospectively maintained clinical database. We compared them with two generative models: Qwen3.5 9B, run locally, and GLM-5.3-flash, run through a cloud API. Tev1 reached a mean field accuracy of 0.917 (95% CI 0.913 to 0.920), the same as Qwen3.5 9B (0.918; p = 0.26), and was four times faster (15 s against 61 s per report). Nimble reached 0.862 and GLM-5.3-flash 0.986. Both decision models matched GLM-5.3-flash on simple dichotomous categories. They were weak on measurements binned into categories, on fields whose correct answer was not reported, and on some complex decisions (e.g. involved margins). We found that the main cause of the inferior performance of Nimble's came from asking 25 questions in one request: with two questions per request, its accuracy improved. Pooled over fields, the returned probabilities were well calibrated (expected calibration error 0.022 and 0.026), but they did not flag systematic errors within single fields. A simulated strategy of sending answers with a probability below 0.94 to GLM-5.3-flash raised Tev1's accuracy to 0.982, with 38% of answers escalated. Decision models can extract explicitly stated findings from pathology reports quickly on local hardware and return useful probabilities. They should be validated in the configuration in which they will be used, restricted to the fields in which they are reliable, and combined with other methods for numeric values.

0.18