CS Paper Radar

A multicenter benchmark and clinically structured metric for coronary CTA report generation

Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu, Tong Hu, Yue Yu, Hairong Zheng, Yining Wang, Tong Zhang

cs.CV ·submitted 2026-09-01 08:38 UTC · v1
benchmarkcode/data

Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

Closest papers

Nearest neighbours by meaning across the whole index.

ImageCAS-X: a dataset and benchmark for coronary artery segmentation and centerline extraction in coronary CT angiography

cs.CV cs.AI ·2026-08-31 ·Kit M. Bransby, Esther Øksnebjerg, Kristoffer Kjær, Jacob Kirkeby, Yasmin El Youssef +5 more
benchmarkdataset similarity 0.66
Abstract · Pre-print (under review)

Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose tissue in coronary computed tomography angiography (CCTA). Cardiologists rely on semi-automated methods for this task because manual vessel tracing and segmentation are labour-intensive. Although many automated methods have been proposed, their validation remains limited by the lack of large, high-quality publicly available datasets. We provide a new dataset of voxel-wise annotations of the vessel lumen and coronary segments, alongside centerlines, and mesh surfaces for 800 scans from the publicly available ImageCAS dataset. Using this dataset, we benchmark established lumen segmentation methods against inter-observer variability, stratifying performance by disease, image quality, coronary dominance, coronary segment, vessel diameter, and lumen attenuation. These labels allow segmentation accuracy to be described in anatomical and clinical context rather than reported as a single aggregate score. The dataset supports the development and validation of methods for lumen segmentation, plaque and perivascular quantification, and haemodynamic modelling.

0.40

Modeling Clinical Workflow for SYNTAX Scoring from Coronary Angiography Videos

cs.CV cs.AI ·2026-09-20 ·Suzhong Fu, Jingqi Dong, Xuan Ding, Rui Sun, Yiming Yang +2 more
top venuecode/data similarity 0.66
Abstract

The SYNTAX score is a clinically established tool for assessing anatomical lesion complexity in coronary artery disease and guiding subsequent treatment. However, automated SYNTAX scoring is commonly formulated as a direct regression problem from coronary angiography videos to patient-level scores. In this work, we reformulate SYNTAX scoring as a vessel segment identity-preserving anatomical reasoning problem and propose a hierarchical modeling framework that explicitly aligns learning with the clinical workflow. Our approach maintains vessel segment identity across frames and views, estimates stenosis severity at the segment level, and aggregates evidence hierarchically according to coronary anatomy. Simultaneously, to address the scarcity of domain-specific data, we integrate and complete multiple public coronary angiography datasets, constructing a large-scale resource featuring completed vessel segmentation and derived structural annotations. Experiments demonstrate that vessel segment-level stenosis embedding enhances explanatory power and reduces prediction variability compared to baseline models, with the R^2 score improving by 0.201 and dev STD decreasing by 18.4%. These results highlight the necessity of structure-aligned modeling for reliable and stable automated SYNTAX scoring from multi-view coronary angiography videos. The GitHub link is https://github.com/VersaceSu7/SYNTAX_score_777.

0.43

Distinguishing Extraction Failures and Clinical Discordance with LLM Uncertainty on Radiology Reports

cs.CL ·2026-11-07 ·Jerjes Aguirre-Chavez, Shant Malkasian, Roshun Sankaran, Brendan Crabb, Albert Hsiao
top venue similarity 0.66
Abstract · Accepted as a spotlight presentation at ML4H 2026, published at Proceedings of Machine Learning Research 346

Large language models (LLMs) can structure clinical datasets, but extraction error must be distinguished from discordance in the underlying data. From a real-world cohort of 1{,}045 patients undergoing coronary CT angiography (CCTA), we evaluated whether LLM uncertainty during vessel-level coronary artery disease (CAD) stenosis extraction could identify extraction failure and clinical discordance. References were expert CCTA annotations (253 patients) and subsequent invasive coronary angiography (ICA; 729 patients). We quantify extraction failure as disagreement between stenosis severity in LLM extracted versus expert annotations, and clinical discordance as disagreement in stenosis severity between CCTA and subsequent ICA. Stenosis Margin, selected from ten candidate measures, was used to quantify LLM uncertainty, and generalized estimating equation logistic regression and AUC evaluated its association and incremental discrimination for each failure mode. LLM uncertainty was strongly associated with extraction failure (adjusted OR 4.15 [95% CI 2.57--6.69], $P<0.001$) and substantially improved discrimination beyond LLM-extracted CCTA stenosis severity alone (AUC 0.81 to 0.86; $Δ$AUC $+0.06$ [$+0.03$, $+0.09$], $P=0.001$). In contrast, LLM uncertainty weakly associated with clinical discordance (adjusted OR 1.22 [1.04--1.43], Holm-adjusted $P=0.118$) but provided no incremental discrimination beyond LLM-extracted CCTA stenosis severity ($Δ$AUC $+0.01$ [$-0.00$, $+0.02$], $P=0.245$). Moreover, extraction errors and clinical discordance showed little overlap, with 38 of 42 clinically discordant vessels (90%) having been extracted correctly. LLM uncertainty may identify extraction failures without identifying underlying clinical discordance, supporting failure attribution when evaluating LLM-derived clinical datasets.

0.43

Auditable CT Phenotyping Through Report-derived Radiological Observations

cs.CV ·2026-08-26 ·Riga Wu, Walter Witschey, Yicheng Li, Felix Barajas Ordonez, Keno K. Bressem +7 more
similarity 0.64
Abstract

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

0.34

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.64
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.13

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation

cs.CV ·2026-09-07 ·Jia-Jen Lee, Shih-Yen Hou, Kee Koon Ng, Wei-Chun Wang, Shih-Sheng Chang
code/data similarity 0.63
Abstract · 25 pages, 3 figures and 4 tables in the main text; supplementary appendix with 5 figures and 1 table. Model weights: https://huggingface.co/…

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-$F_1$. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-$F_1$ (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

0.43

GeoPose: Patient-agnostic CTA-to-DSA registration through projection-space calibration

cs.CV ·2026-08-17 ·Rudolf L. M. van Herten, Robert Graf, Paula Feldman, Johannes C. Paetzold
similarity 0.62
Abstract

Aligning intraoperative biplanar digital subtraction angiography (DSA) to pre-procedural computed tomography angiography (CTA) requires rapid and accurate 3D-to-2D registration. Optimization-based methods are sensitive to initialization and may require hundreds of iterations, whereas learning-based approaches commonly rely on patient-specific training. We propose GeoPose, a population-trained framework that estimates the C-arm pose in a learned canonical frame and transfers it to the native frame of an unseen CTA through projection-space calibration and transform composition. A population-trained residual network refines the pose, followed optionally by low-budget image-driven optimization. GeoPose requires neither patient-specific adaptation nor explicit inter-volume preregistration. On 80 DSA observations from 20 held-out patients, optimization-free GeoPose achieved a carotid mean projected centerline distance (mPCD) of 5.8 mm and a clDice of 0.45, compared with 14.5 mm and 0.28 for the best-performing baseline, while requiring only 0.15 s. After 25 optimization iterations, GeoPose reached an mPCD of 4.6 mm and a clDice of 0.58 in approximately two seconds. Under the same budget, native-initialized optimization achieved 14.6 mm and 0.15, respectively. GeoPose thus provides rapid native-frame registration with fixed population-level weights and the geometric correspondence required for downstream biplanar 3D vascular reconstruction.

0.28

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

eess.IV cs.CV ·2026-11-06 ·Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia +6 more
code/data similarity 0.62
Abstract · 52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

0.49