CS Paper Radar

Beyond Segmentation: Enriching ImageCAS with Coronary Ostia Landmarks, Rooted Centerline Graphs, and Open-Weight Localization Models

Matteo Leccardi, Andrea Moglia, Marco Morandini, Michele Brembilla, Alessandro Nicosia, Andrea Penserini, Christian Brandini, Ender Konukoglu, Marco Marcon, Luca Mainardi, Pietro Cerveri

eess.IV cs.CV ·submitted 2026-11-06 16:56 UTC · v1
code/data

Abstract

Coronary ostia and centerlines are key reference points for automated analysis of coronary computed tomography angiography (CCTA), from surgical planning to intraoperative vessel tracking. However, the only public ostium annotations cover 77 non-gated aortic scans, not CCTA, while CAT08 and ASOCA (32 and 40 CCTA scans) mark the ostia only implicitly, as centerline start points. This work enriches ImageCAS, the largest public dataset for coronary artery segmentation, with ostium annotations for its 1000 patients and centerline graphs rooted at these new ostia, making it, to the authors' knowledge, the largest public dataset for ostium localization and the only one with centerlines following the official ImageCAS masks and starting at annotated ostia. Three annotators marked each ostium in the first 500 volumes; in the next 500, the candidates of a model trained on the first batch were corrected (human-in-the-loop). Six 3D localization models, trained on ImageCAS, CAT08 and ASOCA, were benchmarked on 58 held-out volumes (50 ImageCAS, 4 CAT08, 4 ASOCA). SwinUNETR-V2 and nnResUNet localized all ostia without failure (>5 mm error), with median errors of 0.70-0.87 mm. Trained on CAT08 and ASOCA alone, SwinUNETR-V2 fails on 34% of right and 53% of left ostia, whereas adding 250 ImageCAS volumes removes all failures. The centerlines were extracted by a deterministic, quality-controlled minimal-path procedure; on ASOCA, they cover a median of 99.5% of the reference length, with a median per-patient mean distance of 0.22 mm between matched reference points and centerlines. Annotations, centerlines, code, and weights are available at https://hal9000-lab.github.io/.

Comment
52 pages including the appendices. Dataset, centerlines, code and model weights: https://hal9000-lab.github.io/

Closest papers

Nearest neighbours by meaning across the whole index.

ImageCAS-X: a dataset and benchmark for coronary artery segmentation and centerline extraction in coronary CT angiography

cs.CV cs.AI ·2026-08-31 ·Kit M. Bransby, Esther Øksnebjerg, Kristoffer Kjær, Jacob Kirkeby, Yasmin El Youssef +5 more
benchmarkdataset similarity 0.71
Abstract · Pre-print (under review)

Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose tissue in coronary computed tomography angiography (CCTA). Cardiologists rely on semi-automated methods for this task because manual vessel tracing and segmentation are labour-intensive. Although many automated methods have been proposed, their validation remains limited by the lack of large, high-quality publicly available datasets. We provide a new dataset of voxel-wise annotations of the vessel lumen and coronary segments, alongside centerlines, and mesh surfaces for 800 scans from the publicly available ImageCAS dataset. Using this dataset, we benchmark established lumen segmentation methods against inter-observer variability, stratifying performance by disease, image quality, coronary dominance, coronary segment, vessel diameter, and lumen attenuation. These labels allow segmentation accuracy to be described in anatomical and clinical context rather than reported as a single aggregate score. The dataset supports the development and validation of methods for lumen segmentation, plaque and perivascular quantification, and haemodynamic modelling.

0.40

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.63
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.63
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.62
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.62
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.61
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.61
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

cs.CV ·2026-08-25 ·Lin Xi, Yingliang Ma
similarity 0.59
Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.

0.26