CS Paper Radar

Auditable CT Phenotyping Through Report-derived Radiological Observations

Riga Wu, Walter Witschey, Yicheng Li, Felix Barajas Ordonez, Keno K. Bressem, Lisa C. Adams, Gary E. Weissman, Li Shen, Christos Davatzikos, Eduardo Barbosa, Daniel Truhn, Tianyu Han

cs.CV ·submitted 2026-08-26 16:03 UTC · v1

Abstract

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

Closest papers

Nearest neighbours by meaning across the whole index.

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.68
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.13

A multicenter benchmark and clinically structured metric for coronary CTA report generation

cs.CV ·2026-09-01 ·Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu +5 more
benchmarkcode/data similarity 0.64
Abstract

Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and clinically structured metrics. We established a four-centre benchmark comprising 3,021 CCTA series from 818 patient-report pairs to evaluate seven open-source three-dimensional vision-language models. We developed CSM$_{\text{CCTA}}$, a clinically structured metric for CCTA report evaluation, with patient-, vessel-, and segment-level variables defined according to clinical guidelines. Report pairs are compared at the finest shared anatomical level, and the contributions of different clinical components are weighted based on expert assessments. We estimated these weights using 70 expert-scored cases and evaluated clinical alignment in a non-overlapping set of 30 cases. CSM$_{\text{CCTA}}$ showed a strong correlation with radiologist scores (Pearson's $r=0.97$, $p<0.001$), exceeding the next-best metric, FORTE ($r=0.70$), by 0.27, and agreed with expert preferences in 115 of 160 pairwise comparisons (71.9\%). Under controlled perturbations, CSM$_{\text{CCTA}}$ remained stable to clinically equivalent wording and decreased monotonically with progressive information omission. In the multicenter benchmark, the CCTA-trained C2RG model achieved the highest CSM$_{\text{CCTA}}$ scores across all four hospitals, although its performance remained far from optimal. In contrast, CCTA-irrelevant reports accounted for up to 98.7\% of the outputs from generalist models. Together, the benchmark provides a standardized setting for model comparison, while CSM$_{\text{CCTA}}$ enables clinically structured evaluation of finding agreement and anatomical specificity. These results support a more clinically aligned and anatomically resolved approach to evaluating CCTA report generation. Code is available at https://openi.pcl.ac.cn/OpenMedIA/CSM_CCTA.

0.32

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-27 ·Roy Gabriel, Nattakorn Kittisut, Jamshid Hassanpour, Michael Galarnyk, Abanoub Abdelmalak +4 more
similarity 0.64
Abstract

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

0.46

Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening

cs.CV cs.AI ·2026-09-13 ·Benjamin Renoust, Pierre Baudot, Tiffany Foriel, Yousra Haddou, Charles Voyton +7 more
published similarity 0.63
Abstract · MICCAI CAPTION 2026

Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80-0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization.

0.24

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

cs.CV cs.AI ·2026-09-29 ·Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry +11 more
published similarity 0.63
Abstract

Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

0.25

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

cs.LG cs.CV ·2026-11-05 ·Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran +2 more
benchmark similarity 0.62
Abstract · 10 pages, 1 figure, 6 tables

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

0.24

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.62
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
similarity 0.61
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18