CS Paper Radar

Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening

Benjamin Renoust, Pierre Baudot, Tiffany Foriel, Yousra Haddou, Charles Voyton, Pierre-Henri Siot, Ezequiel Geremia, Danny Francis, Jean-Christophe Brisset, Valérie Bourdès, Sylvain Bodard, Benoit Huet

cs.CV cs.AI ·submitted 2026-09-13 02:43 UTC · v1
published

Abstract

Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80-0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization.

Comment
MICCAI CAPTION 2026

Closest papers

Nearest neighbours by meaning across the whole index.

RadMatch: Auditable Radiology Report Evaluation via Finding-Level Matching

cs.CV ·2026-09-01 ·Charles Corbière, Léo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron +1 more
publishedcode/data similarity 0.68
Abstract · Accepted to ECCV 2026 Workshop on Medical Foundation Models and Benchmarks

As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language model (LLM)-based metrics are now the best-correlated with radiologist judgment, yet they output a single opaque score that neither a clinician nor a model builder can easily interpret or audit. We introduce RadMatch, a multi-stage, LLM-based metric that decomposes report comparison into a structured finding-level matching with significance-aware scoring and error characterization across seven clinical attribute dimensions (status, location, severity, morphology, certainty, longitudinal comparison, and measurement). The main score is the actionable-error count, both interpretable and auditable. Candidate findings are graded correct, partial, or incorrect, and unmatched findings are counted as missed or hallucinated. Triage and actionable safety recall/precision and per-subset views add complementary, deployment-oriented lenses. Across two expert benchmarks, RadMatch is the most clinically aligned metric, matching inter-radiologist agreement on ReXVal and more than doubling the best prior metric on the harder RadEvalExpert. Relying only on few-shot prompting, it is designed to extend to other modalities and anatomies. We will release RadMatch as open-source code with an interactive dashboard for inspecting results.

0.54

Disentangling Lung-Cancer CT/LDCT AI: A Systematic Evidence Map of Clinical Tasks, Evidence Chains, and Translational Gaps

cs.LG ·2026-09-28 ·Surajit Das
similarity 0.67
Abstract

Artificial-intelligence studies using computed tomography (CT) for lung cancer are often broadly labelled "prediction" despite addressing clinically distinct tasks. We systematically mapped CT/low-dose CT (LDCT)-centered lung-cancer AI using five-database retrieval, full-text eligibility assessment, role-aware modality/omics extraction, clinical-task classification, and a Multi-Tier Evidence Graph (MTEG). The final corpus comprised 293 studies (2016-2026): 230 Detection, 8 future Risk-prediction, and 55 Other studies. Clinical variables (96.2%), 3D CT/LDCT (73.0%), and radiomics (63.5%) predominated, whereas external validation (29.0%), calibration (20.5%), decision-curve analysis (13.0%), longitudinal CT (17.7%), and saliency/attribution XAI (21.5%) were less frequent. The MTEG comprised 377 nodes and 3,444 edges; only 31 studies (10.6%) completed the six-tier substantive evidence chain, with greatest attrition at reasoning/explanation. Overall, the literature is detection-dominated, genuine future risk prediction remains uncommon, and complete translational evidence chains are rare.

0.08

RadRef: A Reference-Free Metric for Radiology Report Generation

cs.LG ·2026-11-09 ·Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin +1 more
similarity 0.66
Abstract

AI-generated radiology reports are commonly evaluated against radiologist-authored references, limiting the applicability of standard reference-based metrics when no reference is available. We introduce RadRef, a reference-free metric that scores report claims against image-derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. By evaluating findings beyond the report's stated claims, RadRef assesses omissions as well as unsupported assertions. On ReXVal, RadRef achieves $73.1\%$ agreement with radiologist rankings among non-tied same-radiograph report pairs, with $61.8\%$ pair coverage and $64.3\%$ tie-inclusive agreement. Its non-tied agreement is close to GREEN ($73.9\%$) and RadFact ($72.6\%$), with its strongest relative results on omissions. We further evaluate $100$ model-generated and $100$ radiologist-authored reports from $100$ MIMIC-CXR studies, independently annotated by two board-certified radiologists. On same-image omission rankings, RadRef attains Kendall's $τ_b = 0.295$, compared with $0.386$ between the readers. In separate paired comparisons across generated reports, no evaluated comparator significantly outperforms RadRef on omissions. The same image-grounded representation provides a false-finding readout, RadRef-FF, with $τ_b = 0.32$ on ReXVal and $0.29$ in the reader study. Controlled perturbations confirm that RadRef depends on the radiograph, report, and clinical indication. RadRef enables image-grounded evaluation before a radiologist-authored reference exists, supporting quality monitoring of report-generation systems in clinical settings, and complements reference-based metrics when one is available.

0.17

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

cs.CL cs.AI ·2026-09-16 ·Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency +3 more
similarity 0.65
Abstract · Preprint

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

0.10

FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making

cs.CV cs.AI ·2026-08-15 ·Pramit Dutta, Jenita Manokaran, Richa Mittal, Ryan Appleby, Eranga Ukwatta
similarity 0.65
Abstract

Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18\% accuracy for anatomical location, 67.96\% accuracy for margin characteristics, and 79.13\% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9\% accuracy, 98.6\% completeness score, 76.1\% clinical relevance, and an overall score of 89.5\%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.

0.04

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
similarity 0.64
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.64
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.13

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.64
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30