CS Paper Radar

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry, Rohan Isaac, Bardia Khosravi, Hanzhou Li, Frank Li, John T. Moon, Chad Robichaux, Dan I. G. Cohen-Addad, Ninad V. Salastekar, Janice Newsome, Judy W. Gichoya, Hari Trivedi

cs.CV cs.AI ·submitted 2026-09-29 15:00 UTC · v1
published

Abstract

Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

Closest papers

Nearest neighbours by meaning across the whole index.

Unified-protocol voxel-level pulmonary embolism annotations for three public CT angiography datasets

eess.IV cs.CV ·2026-08-25 ·Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang +4 more
similarity 0.70
Abstract · 18 pages, 5 figures, 1 table

Reliable clot-volume quantification and subsequent risk assessment in pulmonary embolism depend on precise segmentation of emboli on computed tomography pulmonary angiography. Deep learning models for this task must be trained on accurate voxel-level labels. The three public datasets that provide such labels were annotated under different protocols, and some of their studies contain unlabeled emboli or labels that are discontinuous across slices. This Data Descriptor presents voxel-level pulmonary embolism annotations for 149 of the 166 studies in these datasets. A primary rater drew all annotations under a single protocol. A thoracic radiologist with more than 20 years of experience reviewed and revised them. Three raters at three different centers independently annotated a subset of 15 studies. The subset was selected by source dataset and embolus location. Technical validation quantifies volumetric agreement with the source annotations, changes in within-mask attenuation, and inter-rater agreement on the subset. The dataset is intended to allow segmentation models to be developed and compared under a common reference standard.

0.37

Disentangling Lung-Cancer CT/LDCT AI: A Systematic Evidence Map of Clinical Tasks, Evidence Chains, and Translational Gaps

cs.LG ·2026-09-28 ·Surajit Das
similarity 0.64
Abstract

Artificial-intelligence studies using computed tomography (CT) for lung cancer are often broadly labelled "prediction" despite addressing clinically distinct tasks. We systematically mapped CT/low-dose CT (LDCT)-centered lung-cancer AI using five-database retrieval, full-text eligibility assessment, role-aware modality/omics extraction, clinical-task classification, and a Multi-Tier Evidence Graph (MTEG). The final corpus comprised 293 studies (2016-2026): 230 Detection, 8 future Risk-prediction, and 55 Other studies. Clinical variables (96.2%), 3D CT/LDCT (73.0%), and radiomics (63.5%) predominated, whereas external validation (29.0%), calibration (20.5%), decision-curve analysis (13.0%), longitudinal CT (17.7%), and saliency/attribution XAI (21.5%) were less frequent. The MTEG comprised 377 nodes and 3,444 edges; only 31 studies (10.6%) completed the six-tier substantive evidence chain, with greatest attrition at reasoning/explanation. Overall, the literature is detection-dominated, genuine future risk prediction remains uncommon, and complete translational evidence chains are rare.

0.08

Auditable CT Phenotyping Through Report-derived Radiological Observations

cs.CV ·2026-08-26 ·Riga Wu, Walter Witschey, Yicheng Li, Felix Barajas Ordonez, Keno K. Bressem +7 more
similarity 0.63
Abstract

Medical image foundation models can predict clinical phenotypes from computed tomography (CT), but strong performance leaves open whether they read disease-specific findings or shortcuts that correlate with the diagnosis. We tested this in 221 electronic-health-record (EHR) phenotypes using Auditable CT phenotyping (ACT), built on report-derived radiological observations. We trained ACT on 38,317 patients, mined 376,194 observations and evaluated it in 25,183 held-out patients. ACT exceeded five vision-language baselines on zero-shot annotation, and CT-CLIP across 221 phenotypes from unseen CT pulmonary angiography, both under zero-shot scoring (0.651 versus 0.572) and under linear probing (0.709 versus 0.662). Reading each probe exposes what accuracy conceals: only 97 observations occupy the 221 rank-1 positions, and one phrase describing aortic and coronary calcification ranks first for 20 phenotypes, including osteoporosis, urinary tract infection and major depressive disorder. Restricting the bank to clinician-specified evidence redirects those probes onto phenotype-related observations in 86 phenotypes at no accuracy cost (0.751 versus 0.741). Accurate CT-based EHR phenotyping can therefore rest on observations that are not valid evidence for the coded phenotype and that ACT can identify and intervene on.

0.53

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.62
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.26

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

cs.LG cs.HC ·2026-09-24 ·Nathan Le, Magdalini Paschali, Arogya Koirala, Andrew Johnston, Zhongnan Fang +3 more
publishedcode/data similarity 0.61
Abstract · 11 pages, 3 figures, 1 table. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imagin…

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as MC Dropout and Deep Ensembles, require access to model parameters or retraining. However, proprietary clinical AI systems operate as black boxes, preventing access to the model's internals. To that end, we propose a model-agnostic framework for improving calibration of black-box models using clinically grounded test-time augmentation (TTA). Our framework applies geometric and physics-inspired 3D CT perturbations and learns probability-level aggregation strategies without access to model internals or the original training data. Across pulmonary embolism and intracranial hemorrhage detection tasks, DualTTA achieved the strongest overall calibration among TTA methods, reducing the Expected Calibration Error by 54% (0.239 -> 0.109) and 43% (0.051 -> 0.029), respectively, while requiring only input-output access. Additionally, DualTTA outperformed uncertainty estimation techniques that require access to model internals, such as Temperature Scaling, MC Dropout, and Deep Ensembles, in most calibration metrics. These results demonstrate that learned TTA aggregation can improve the calibration of clinical AI systems, providing a practical approach for improving the reliability of black-box medical AI.

0.45

Performance vs Consistency: Evaluating a Foundation Model in Lung-RADS Screening

cs.CV cs.AI ·2026-09-13 ·Benjamin Renoust, Pierre Baudot, Tiffany Foriel, Yousra Haddou, Charles Voyton +7 more
published similarity 0.60
Abstract · MICCAI CAPTION 2026

Foundation models have recently demonstrated strong capabilities across a wide range of medical imaging tasks. However, their performance in structured clinical interpretation settings remains insufficiently explored. In lung cancer screening, interpretative variability persists despite standardized frameworks such as Lung-RADS. In this study, we evaluate MedGemma, a medical general-purpose foundation model derived from Gemini and its fine-tuned version adapted for lung cancer detection and diagnosis, compared against radiologists performing Lung-RADS v2022 assessment on the NLST dataset. Twelve radiologists independently evaluated each case in a multi-reader design, enabling quantification of inter-reader variability. Radiologists achieved a mean AUC of 0.90, with substantial variability across readers (range: 0.80-0.94). The native foundation model achieved an AUC of 0.70, failing to reach clinically relevant performance. In contrast, fine-tuning significantly improved performance to an AUC of 0.83, placing the model within the lower range of individual radiologists performance. These findings highlight a trade-off between peak accuracy and prediction consistency. Unlike radiologists, under fixed conditions, the model produces deterministic outputs, removing inter-run variability under identical inputs, in contrast to inter-reader variability observed among radiologists. This supports the role of fine-tuned foundation models potential complementary tools for clinical decision support, particularly in settings with limited expertise. However, evaluation is performed on a case-enriched cohort from NLST and does not account for real-world prevalence or external validation, limiting direct clinical generalization.

0.24

Hierarchical MoE for Multi-Modal ILD Diagnosis

cs.AI cs.CV ·2026-08-26 ·Alec K. Peltekian, Gorkem Durak, Halil Ertugrul Aktas, Carrie Lynn Richardson, Mary Carns +7 more
top venue similarity 0.60
Abstract · 11 pages, 2 figures

Mixture-of-experts (MoE) models combine specialized predictors under learned routing, offering a principled mechanism for leveraging heterogeneity in medical data. We present a hierarchical multimodal MoE for interstitial lung disease (ILD) classification that integrates a frozen, pre-trained imaging expert with structured electronic health records (EHR) via two-stage gating. A modality-level gate assigns patient-specific weights to imaging and EHR predictions, while a sub-gating module decomposes the EHR branch into clinically defined feature groups with learned, group-specific contributions. This design preserves stable imaging representations while enabling input-dependent clinical weighting and explicit EHR specialization. Under strict patient-level cross-validation, the model achieved the highest mean AUC among the evaluated methods (0.8750 +- 0.0443), compared with 0.8646 for imaging-only REN and 0.7685 for SwinUNETR. The framework extends interpretability across anatomical regions, imaging--EHR utilization, and clinically defined EHR feature groups.

0.47

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.60
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.12