CS Paper Radar

Unified-protocol voxel-level pulmonary embolism annotations for three public CT angiography datasets

Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang, Lei Zhang, Lixiang Xie, Jiazhen Pan, Christian Wachinger

eess.IV cs.CV ·submitted 2026-08-25 12:34 UTC · v2

Abstract

Reliable clot-volume quantification and subsequent risk assessment in pulmonary embolism depend on precise segmentation of emboli on computed tomography pulmonary angiography. Deep learning models for this task must be trained on accurate voxel-level labels. The three public datasets that provide such labels were annotated under different protocols, and some of their studies contain unlabeled emboli or labels that are discontinuous across slices. This Data Descriptor presents voxel-level pulmonary embolism annotations for 149 of the 166 studies in these datasets. A primary rater drew all annotations under a single protocol. A thoracic radiologist with more than 20 years of experience reviewed and revised them. Three raters at three different centers independently annotated a subset of 15 studies. The subset was selected by source dataset and embolus location. Technical validation quantifies volumetric agreement with the source annotations, changes in within-mask attenuation, and inter-rater agreement on the subset. The dataset is intended to allow segmentation models to be developed and compared under a common reference standard.

Comment
18 pages, 5 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Multi-Site Real-World Performance of Commercial AI for Pulmonary and Incidental Pulmonary Embolism Detection

cs.CV cs.AI ·2026-09-29 ·Aawez Mansuri, Mohammadreza Chavoshi, Theodorus Dapamede, Wasif Bala, Beatrice Brown-Mulry +11 more
published similarity 0.70
Abstract

Pulmonary embolism (PE) is a leading cause of cardiovascular mortality, yet the real-world performance of FDA-cleared AI detection models remains incompletely characterized. We retrospectively evaluated two FDA-cleared AI algorithms from a single commercial platform (Aidoc Medical BriefCase), one for PE triage on dedicated CT pulmonary angiography (CTPA; n = 30,678) and one for incidental PE (iPE) detection on routine contrast-enhanced CTs (n = 37,191), across a 17-facility academic health system. Reference-standard labels were extracted from radiology reports using a validated LLM pipeline (97% accuracy, kappa = 0.94). The PE model achieved 86.8% sensitivity and 99.1% specificity, with sensitivity declining from 99.3% for saddle emboli to 72.9% for subsegmental PE, and from 89.7% for acute to 65.3% for non-acute PE. The iPE model achieved 73.5% sensitivity and 99.8% specificity. Both models demonstrated lower sensitivity than FDA-clearance benchmarks while exceeding cleared specificity, with diminishing performance for peripheral and non-acute emboli mirroring known human reader limitations and underscoring the need for standardized post-market surveillance of AI-enabled medical devices.

0.25

Evaluating Multi-Task Morphological Concept Learning for Pulmonary Nodule Malignancy Assessment in 3D CT

cs.CV ·2026-09-29 ·Namitha Narayanan
similarity 0.65
Abstract · 8 pages, 3 figures, 5 tables

Morphological characteristics such as spiculation and lobulation play an important role in assessing pulmonary nodules on computed tomography (CT), particularly in relation to malignancy risk. This study examines whether learning radiologist-annotated morphological features together with malignancy risk from lesion-centred 3D CT volumes improves classification performance. The Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset was used, comprising 3,918 reader-level nodule annotations from 742 patients after excluding indeterminate malignancy ratings. Patient-level splitting was used for training, validation, and testing, with 112 patients and 628 reader annotations in the held-out test set. A single-task 3D convolutional neural network was compared with a multi-task model predicting malignancy risk, spiculation, and lobulation. The single-task model achieved a balanced accuracy of 0.548 and receiver operating characteristic area under the curve (ROC-AUC) of 0.552, while the multi-task model achieved 0.539 and 0.558, respectively. Patient-level bootstrap analysis showed an ROC-AUC difference of 0.005 (95% confidence interval (CI): -0.087 to 0.090) and a balanced-accuracy difference of -0.009 (95% CI: -0.067 to 0.043). The auxiliary tasks were strongly imbalanced and showed limited predictive performance. Overall, including morphological features did not clearly improve malignancy-risk classification, showing the importance of class balance, label formulation, and reader-level annotation structure in multi-task pulmonary CT analysis.

0.15

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.64
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

PCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cues

cs.CV ·2026-10-18 ·Xueyang Li, Alec Girten, Peng Zeng, Mingze Jiang, Shaoyang Huang +4 more
similarity 0.64
Abstract

Patients admitted to pediatric ICU and cardiac ICU often require intensive perioperative support and frequent chest radiography to monitor support devices, extravascular lung water, and body-wall edema. Radiographic interpretation and analysis is often difficult due to superimposed anatomic and iatrogenic structures that obscure clinically relevant signals. While deep learning can provide decision support, translation to pediatric radiographs is still limited by high device burden and scarcity of pediatric datasets with clinically grounded device annotations. To address this gap, we first introduce PediaDeviceSeg-1K, a curated dataset of 1,000 anterior-posterior radiographs of pediatric CICU patients with clinically grounded, fine-grained annotations of common ICU devices. To our best knowledge, this is the first publicly available pediatric CICU CXR resource with clinically grounded device annotations for device-focused benchmarking. Building on PediaDeviceSeg-1K, we further present PCXR-Copilot, a device-aware pipeline that outputs lung and device masks, optional device-suppressed views, and edema-related visualization maps and scalar indices. The full pipeline has been integrated and runs in real time within the TWIST platform at Boston Children's Hospital, demonstrating feasibility for real-world clinical deployment.

0.11

Semi-Supervised GAN-Based Segmentation of CTPA Scans for Pulmonary Emboli Boundary Extraction

cs.CV cs.LG ·2026-11-18 ·Maria Thoma, Michalis Savelonas, Foteini Malli, Dimitris Iakovidis
published similarity 0.64
Abstract · 2026 IEEE 39th International Symposium on Computer-Based Medical Systems (CBMS), Limassol, Cyprus

Pulmonary embolism (PE) is a pulmonary vascular disease associated with high morbidity and mortality, where delayed diagnosis can be fatal. While computed tomography pulmonary angiography (CTPA) is the clinical gold standard for PE detection, interpreting these scans manually is time-consuming and error-prone. In this work, we propose a semi-supervised segmentation method, employing generative adversarial networks (GANs) to leverage large pools of unlabeled CTPA scans. The proposed method addresses more effectively the challenges of CTPA image segmentation than previous methods by employing the dice loss and the cross-entropy loss to tackle the highly imbalanced nature of CTPA scans, the feature matching loss to encourage the generator to produce anatomically plausible segmentation maps that are indistinguishable from ground truth, as well as the self-training loss to reinforce learning from highly-confident pseudo-labeled samples. The experimental evaluation on a publicly available dataset shows that the proposed method maintains accurate segmentation, despite a limited number of labeled CTPA scans. with a Dice coefficient of 88.75% and a 95th percentile Hausdorff distance (HD95) of 1.74, outperforming fully supervised baselines.

0.24

ConfTriage: A Calibration-Aware LLM Triage Framework for Pulmonary Nodule Malignancy with Selective Specialist Deferral

cs.CV ·2026-08-11 ·Md Rabiul Islam, Samir Abdaljalil, Erchin Serpedin, Hasan Kurban
theorycode/data similarity 0.64
Abstract · 14 pages, 8 figures. Currently under review

Pulmonary nodule malignancy prediction typically depends on image-trained specialist deep learning (DL) models that require substantial annotated imaging data and task-specific training. We investigate whether a generalist large language model (LLM), reading only a faithful natural-language rendering of standard nodule attributes, can serve as a calibrated triage layer. We propose ConfTriage, a confidence-calibrated method built on three pillars: language as the modality, calibration as the safety mechanism, and a selective specialist DL backstop for low-confidence cases. We prove two guarantees: a finite-sample combined-error bound yielding an explicit per-threshold operational certificate, and an oracle inequality showing that excess risk over the Bayes-optimal deferral classifier is controlled by the L1 calibration error of the LLM probability. A controlled seven-way input ablation across five frontier LLMs on LIDC-IDRI shows that natural-language descriptions dominate the diagnostic signal, while low-level image statistics are essentially diagnostically vacuous. ConfTriage achieved an F1 score of 88.22% and an AUC of 0.92, resolving 76.5% of cases using zero-shot LLM inference alone and referring only uncertain cases to the specialist DL backstop. These results demonstrate that clinically meaningful diagnostic information can be captured through structured radiological descriptions and leveraged by calibrated LLMs for selective referral. The framework suggests a practical pathway for combining generalist LLM prediction with specialist AI models in medical decision-support systems. Source code is publicly available at https://github.com/rabiul-ai/ConfTriage.

0.32

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
similarity 0.64
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.63
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16