CS Paper Radar

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling, Hang Min, Julie Chu, Jennifer Tan, Phillip K. Tran, Tomas Kron, Annette Haworth, Martin A. Ebert, Shalini K. Vinod, Lois Holloway

cs.CV physics.med-ph ·submitted 2026-09-02 22:03 UTC · v1

Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

Closest papers

Nearest neighbours by meaning across the whole index.

Anatomical Prior-Guided Routing for 3D Lung Tumor Segmentation

cs.CV ·2026-10-29 ·Uihyeon Maeng, Jonghun Kim, Hyunjin Park
published similarity 0.73
Abstract · Accepted to ACCV 2026 (Oral), 18 pages, 6 figures

Accurate lung tumor segmentation in computed tomography (CT) is essential for treatment planning, response assessment, and quantitative imaging analysis. However, 3D lung tumor segmentation remains challenging because tumors occupy only a small portion of the whole volume and exhibit heterogeneous appearances across anatomical locations. In patch-based training and sliding-window inference for 3D medical image segmentation, location-dependent heterogeneity is further amplified because cropped image patches provide limited global anatomical context, making it difficult for a model to adapt its feature processing according to the anatomical region from which each patch is extracted. To address this limitation, we propose an Anatomical Prior-guided Routing Module (APRM) for lung tumor segmentation. For each image patch, we obtain anatomical prior information of regional occupancy and deterministically select an anatomical routing gate. The selected gate then performs sparse feature routing over a shared expert adapter pool, enabling anatomy-specific feature adaptation while sharing expert capacity across regions. We evaluate APRM on two datasets with various backbone networks and demonstrate consistent improvements over baseline models. Furthermore, feature visualizations show that APRM produces different feature responses depending on patch location, indicating that the proposed routing mechanism effectively adapts feature processing according to anatomical context.

0.26

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.72
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Pretrained, Curriculum-Tuned, and Ensembled: A Tracer-Aware Interactive Segmentation Pipeline for AutoPET V

cs.CV cs.AI ·2026-08-31 ·Xinglong Liang, Chunyao Lu, Tianyu Zhang, Jiaju Huang, Tao Tan +2 more
code/data similarity 0.71
Abstract

Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to sparse corrective scribbles during inference. This setting is particularly challenging because tracer distributions, physiological uptake patterns, lesion appearance, and acquisition characteristics differ substantially between FDG and PSMA studies. We present TRIAGE, Tracer-aware Refinement via Interactive Anatomy-Guided sEgmentation. The core backbone is a 3D STU-Net initialized through masked autoencoding pre-training with an asynchronous masking strategy, aiming to learn transferable anatomical and cross-modal representations before task-specific fine-tuning. In parallel, we train an auxiliary organ segmentation model whose predictions provide explicit anatomical context and help distinguish physiological uptake from malignant lesions. A dedicated tracer classifier first routes each study to an FDG- or PSMA-specific branch. Within each branch, a first-stage segmentation model consumes CT, PET, and organ context to generate an initial lesion mask. The initial prediction is then combined with cumulative foreground/background scribbles and refined by a second interactive segmentation network. The FDG and PSMA branches share the same overall processing pipeline but are trained independently to account for tracer-specific appearance and error modes. We additionally employ curriculum-style training and model ensembling to improve robustness across interaction steps and heterogeneous cohorts. Experiments are conducted using the official AutoPET V data and ten-fold split; quantitative results, ablations, and final test-set performance are left as placeholders to be completed after the challenge evaluation. Code: https://github.com/Liiiii2101/AUTOPET2026-MEDAI.

0.24

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.71
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.71
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.71
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.70
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.70
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28