CS Paper Radar

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten, L. D. Kampmeijer, Joost Nederend, Fons van der Sommen

eess.IV cs.CV ·submitted 2026-08-28 09:15 UTC · v1
published

Abstract

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

Comment
Accepted as a CaPTion workshop paper at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.71
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Colorectal Cancer Segmentation with Adaptive Augmentation and Multi-Resolution Ensemble Models

eess.IV cs.AIcs.CV ·2026-09-29 ·Ümit Mert Çağlar, Alptekin Temizel
publishedcode/data similarity 0.67
Abstract · SPIE Eighteenth International Conference on Machine Vision (ICMV 2025), Paris, France

Colorectal cancer (CRC) is the second most deadly and third most common cancer, and the leading cause of death among gastrointestinal cancers. Early diagnosis is crucial for the treatment of this cancer and increasing the survival rates. Although CRC is more common in developed regions, its occurrence is also increasing in developing regions as well. CRC diagnosis relies on histopathology assessment post-biopsy. Automated deep learning algorithms can significantly reduce diagnosis time, enhancing efficiency and supporting timely clinical decisions. We present an automated segmentation pipeline for whole-slide histopathology images that labels tumor grades 1-3 and normal mucosa. It utilizes dense prediction transformers with various encoder backbones, overlapping patches, and test-time augmentation. An adaptive augmentation policy, guided by large language models, further improves training. Top models were ensembled via soft voting, and mask refining post-processing steps, Gaussian blurring, morphological closing, and connected components analysis. On a colorectal cancer grade dataset, our method improved the F1 score from 62.92 to 69.84. Code is available here: github.com/caglarmert/ICIP2025

0.34

Spectral Adapters for Segment Anything Model-based Segmentation of Colorectal Liver Metastases in Computed Tomography

cs.CV ·2026-09-10 ·Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen +4 more
similarity 0.67
Abstract · 13 pages, 1 figure, 4 tables

Accurate segmentation of colorectal liver metastases (CRLM) in contrast-enhanced computed tomography (CT) is important for response assessment, surgical planning, and follow-up. We propose two parameter-efficient spectral adapters for the Segment Anything Model (SAM): the Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA). DiSECT uses singular value decomposition of frozen weights to constrain residual updates to leading spectral directions, while SiGA adds global and input-conditioned gating through a multilayer perceptron. We evaluate these methods on 446 contrast-enhanced CT volumes (355 training, 91 testing) and compare them with LoRA, QLoRA, convolutional adapters (CAD), and a 3D nnU-Net baseline. Experiments consider single-point, three-point, bounding-box, and no-prompt regimes. SiGA achieves the best single-point performance with a Dice score of 0.77, IoU of 0.69, and HD95 of 35.39 mm. Under no-prompt inference, SiGA reaches 0.76 Dice, 0.68 IoU, and 46.76 mm HD95, comparable to the nnU-Net baseline (0.758 Dice). DiSECT uses only 0.14 million trainable parameters. These results show that spectral adapters can efficiently adapt SAM for CRLM segmentation while retaining strong accuracy with limited trainable parameters.

0.31

SAMI3D-DW: Interactive Segmentation of Any 3D Medical Images

cs.CV ·2026-09-22 ·Ping Gong, Shiyuan Su, Fandong Zhang, Xinchen Han, Haowei Sun +2 more
benchmark similarity 0.66
Abstract · 28 pages, 5 figures; replacement version with reordered category-level Dice scores presentation to better reflect clinical conventions., cla…

Interactive segmentation of 3D medical images supports quantitative analysis of anatomical structures and disease while allowing users to specify and refine their targets. Despite substantial progress by nnInteractive and VISTA3D, reliable segmentation across diverse clinical targets remains challenging, particularly for complex anatomical structures and the heterogeneous, long-tailed spectrum of pathology. We present SAMI3D-DW V1 (hereafter SAMI3D-DW), an interactive 3D segmentation model trained on Deepwise's large-scale proprietary medical image datasets. We evaluate the model under simulated user interactions on a CT/MR benchmark comprising 4,326 cases from 219 source datasets, spanning 107 anatomical and pathological categories, organized by a medical taxonomy and evaluated with a category-balanced DSC score. SAMI3D-DW achieves the highest category-macro Dice among evaluated methods in both interaction modes. With one point, it scores 0.5756 versus 0.5316 for nnInteractive, the strongest baseline, rising to 0.7771 versus 0.7495 with five points. With bounding-box initialization, the scores are 0.7129 versus 0.6530. After five corrective clicks, SAMI3D-DW reaches 0.8004 versus 0.7868. For radiologists and clinicians, SAMI3D-DW enables segmentation of complex anatomical structures, including intracranial vessel trees on CT and MR angiography, with a few clicks. In a preliminary in-house comparison involving neurofibromatosis type 1 (NF1), SAMI3D-DW-assisted tumor annotation took minutes per case and approximately one-fifteenth of the time required for manual annotation, highlighting its potential to support volumetric treatment-response assessment.

0.23

Beyond Boundary Noise: Aggregated Aleatoric Uncertainty Fails to Capture Presence Ambiguity in 3D Lung Nodule Segmentation

cs.CV cs.LG ·2026-08-14 ·Simon Baur, Arne Schernich, Ekin Böke, Wojciech Samek, Jackie Ma
similarity 0.65
Abstract

Uncertainty estimation is critical for the safe clinical deployment of deep learning in medical image segmentation, with aleatoric uncertainty theoretically designed to capture irreducible data ambiguity. However, whether entropy-based measures reflect clinically meaningful ambiguity, i.e. case-level disagreement about whether a pathology is present at all, remains poorly understood. Contrary to most prior work, which focused on pixel-wise boundary disagreement, we systematically evaluate how well aleatoric uncertainty captures presence ambiguity. Our evaluation spans 3D lung nodule segmentation across four architectures with Monte Carlo dropout and deep ensembles, on LIDC-IDRI and an external validation cohort (LNDb). We find that entropy-based uncertainty maps align with boundary noise and minor drawing variation but carry insufficient discriminative signal for presence ambiguity. In contrast, a lightweight supervised ambiguity head trained on frozen segmentation features substantially outperforms all entropy-aggregation-based baselines across architectures, metrics, and both cohorts, and matches or exceeds methods that explicitly model ambiguity under disagreement supervision (Probabilistic U-Net, Annotator-Confusion 3D-UNet). A qualitative feature-space analysis shows that presence ambiguity is already encoded in the frozen encoder features of pixel-wise-trained networks, only to be discarded by the segmentation output and its entropy aggregation. Our findings expose a fundamental mismatch between the theoretical promise of aleatoric uncertainty and its practical behavior, and suggest that practitioners should not rely on entropy-based uncertainty as a proxy for clinical ambiguity in safety-critical applications.

0.34

Parameter-Efficient Fine-Tuning of Foundation Models for Liver Tumor Segmentation in CT

cs.CV ·2026-09-12 ·Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson
publishedcode/data similarity 0.64
Abstract · 9 pages, 2 figures, 1 table. Author manuscript of the published SPIE 2026 proceedings paper; LaTeX reconstructed from the author PDF

We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal liver metastases. We compared Low-Rank Adaptation (LoRA), 4-bit Quantized LoRA (QLoRA), a convolutional adapter (Conv-Adapter), and our Directional Spectral Top-K adapter (DiSCo), training only adapters while freezing the SAM backbone. DiSCo derives spectral bases from singular value decomposition of row-normalized weights and learns rank-gated spectral coefficients, per-output magnitude offsets, and a spectral gain, with optional Top-K rank selection at inference and 0.14 M trainable parameters. We benchmarked five prompting regimes: no prompt, single-point, multi-point, and bounding boxes at intersection over union 0.50 and 0.75. Conv-Adapter and LoRA achieved the highest accuracy (overall Dice 0.793 and 0.792; single-point Dice 0.795 and 0.792; 95th-percentile Hausdorff distance (HD95) 32 mm). QLoRA was close (overall Dice 0.766; single-point Dice 0.768; HD95 36.41 mm), with 0.91 M trainable parameters, 120 ms latency, and 4.9 GB peak memory. DiSCo achieved the highest Dice per million trainable parameters (4.66), with overall Dice 0.653, single-point Dice 0.698, and HD95 49.53 mm. These results show an accuracy-efficiency trade-off and support PEFT for liver tumor segmentation with reduced adaptation costs when compute and labeled data are limited. Code: https://github.com/Ramtin-Mojtahedi/PEFT-SAM-Liver-CT

0.67

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.64
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.64
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32