CS Paper Radar

Parameter-Efficient Fine-Tuning of Foundation Models for Liver Tumor Segmentation in CT

Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson

cs.CV ·submitted 2026-09-12 19:07 UTC · v1
publishedcode/data

Abstract

We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal liver metastases. We compared Low-Rank Adaptation (LoRA), 4-bit Quantized LoRA (QLoRA), a convolutional adapter (Conv-Adapter), and our Directional Spectral Top-K adapter (DiSCo), training only adapters while freezing the SAM backbone. DiSCo derives spectral bases from singular value decomposition of row-normalized weights and learns rank-gated spectral coefficients, per-output magnitude offsets, and a spectral gain, with optional Top-K rank selection at inference and 0.14 M trainable parameters. We benchmarked five prompting regimes: no prompt, single-point, multi-point, and bounding boxes at intersection over union 0.50 and 0.75. Conv-Adapter and LoRA achieved the highest accuracy (overall Dice 0.793 and 0.792; single-point Dice 0.795 and 0.792; 95th-percentile Hausdorff distance (HD95) 32 mm). QLoRA was close (overall Dice 0.766; single-point Dice 0.768; HD95 36.41 mm), with 0.91 M trainable parameters, 120 ms latency, and 4.9 GB peak memory. DiSCo achieved the highest Dice per million trainable parameters (4.66), with overall Dice 0.653, single-point Dice 0.698, and HD95 49.53 mm. These results show an accuracy-efficiency trade-off and support PEFT for liver tumor segmentation with reduced adaptation costs when compute and labeled data are limited. Code: https://github.com/Ramtin-Mojtahedi/PEFT-SAM-Liver-CT

Comment
9 pages, 2 figures, 1 table. Author manuscript of the published SPIE 2026 proceedings paper; LaTeX reconstructed from the author PDF
Journal ref
Proc. SPIE 13926, Medical Imaging 2026: Computer-Aided Diagnosis, 1392612 (2026)
DOI
10.1117/12.3087835

Closest papers

Nearest neighbours by meaning across the whole index.

Spectral Adapters for Segment Anything Model-based Segmentation of Colorectal Liver Metastases in Computed Tomography

cs.CV ·2026-09-10 ·Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen +4 more
similarity 0.83
Abstract · 13 pages, 1 figure, 4 tables

Accurate segmentation of colorectal liver metastases (CRLM) in contrast-enhanced computed tomography (CT) is important for response assessment, surgical planning, and follow-up. We propose two parameter-efficient spectral adapters for the Segment Anything Model (SAM): the Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA). DiSECT uses singular value decomposition of frozen weights to constrain residual updates to leading spectral directions, while SiGA adds global and input-conditioned gating through a multilayer perceptron. We evaluate these methods on 446 contrast-enhanced CT volumes (355 training, 91 testing) and compare them with LoRA, QLoRA, convolutional adapters (CAD), and a 3D nnU-Net baseline. Experiments consider single-point, three-point, bounding-box, and no-prompt regimes. SiGA achieves the best single-point performance with a Dice score of 0.77, IoU of 0.69, and HD95 of 35.39 mm. Under no-prompt inference, SiGA reaches 0.76 Dice, 0.68 IoU, and 46.76 mm HD95, comparable to the nnU-Net baseline (0.758 Dice). DiSECT uses only 0.14 million trainable parameters. These results show that spectral adapters can efficiently adapt SAM for CRLM segmentation while retaining strong accuracy with limited trainable parameters.

0.31

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

cs.CV cs.LG ·2026-11-17 ·Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
published similarity 0.65
Abstract · 25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower H…

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

0.37

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.64
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs

cs.CV ·2026-08-27 ·Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
published similarity 0.63
Abstract · Accepted to the Medical Image AI in Radiation Therapy (MIART) Workshop at MICCAI 2026

Accurate rectal cancer segmentation from magnetic resonance imaging (MRI) is essential for adaptive radiotherapy and tumor response assessment, but deployment also requires computational efficiency and informative, calibrated uncertainty estimates. We therefore introduce SWIFT, a SWin pretrained model wIth parameter-eFficient and Tumor-aware fine-tuning for rectal cancer segmentation. A Swin V2 encoder pretrained on 10,444 public 3D CT volumes using a DINOv2-style objective was adapted to T2-weighted MRI through four cumulative configurations: full fine-tuning (SWIFT), decoder compression (SWIFTe), low-rank adaptation (SWIFTe-LoRA), and a four-member LoRA-decoder ensemble (SWIFTe-LDE4). Geometric accuracy, tumor detection, radiomic agreement, and probability calibration were evaluated on a held-out 247-case test set from a single-institution cohort acquired using 1.5 or 3 Tesla GE scanners. Compared with SWIFT, SWIFTe reduced total parameters by 70.1% (from 72.8M to 21.8M) and increased tumor detection rate from 89.9% to 93.9%, while achieving a slightly lower median surface DSC (0.61 versus 0.62) and improved radiomic agreement. In a separate SWIFTe ablation, removing tumor-aware augmentation reduced detection from 93.9% to 89.9% but increased surface DSC from 0.61 to 0.64, demonstrating a detection-boundary-agreement trade-off. SWIFTe-LoRA used 14.6% of SWIFTe's trainable parameters while retaining similar segmentation performance. SWIFTe-LDE4 achieved the lowest calibration errors among the four configurations after temperature scaling (expected calibration error, 0.217; Brier score, 0.222), although the absolute expected calibration error indicates residual miscalibration. Similar efficiency-calibration patterns were observed using the public VoCo checkpoint, supporting robustness across pretrained initializations rather than external clinical generalizability.

0.41

Colorectal Cancer Segmentation with Adaptive Augmentation and Multi-Resolution Ensemble Models

eess.IV cs.AIcs.CV ·2026-09-29 ·Ümit Mert Çağlar, Alptekin Temizel
publishedcode/data similarity 0.63
Abstract · SPIE Eighteenth International Conference on Machine Vision (ICMV 2025), Paris, France

Colorectal cancer (CRC) is the second most deadly and third most common cancer, and the leading cause of death among gastrointestinal cancers. Early diagnosis is crucial for the treatment of this cancer and increasing the survival rates. Although CRC is more common in developed regions, its occurrence is also increasing in developing regions as well. CRC diagnosis relies on histopathology assessment post-biopsy. Automated deep learning algorithms can significantly reduce diagnosis time, enhancing efficiency and supporting timely clinical decisions. We present an automated segmentation pipeline for whole-slide histopathology images that labels tumor grades 1-3 and normal mucosa. It utilizes dense prediction transformers with various encoder backbones, overlapping patches, and test-time augmentation. An adaptive augmentation policy, guided by large language models, further improves training. Top models were ensembled via soft voting, and mask refining post-processing steps, Gaussian blurring, morphological closing, and connected components analysis. On a colorectal cancer grade dataset, our method improved the F1 score from 62.92 to 69.84. Code is available here: github.com/caglarmert/ICIP2025

0.34

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.63
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

Task-Performance Routing for Multi-Teacher Distillation in CT Medical Image Segmentation

cs.CV ·2026-10-30 ·Jiaye Yang, Yao Liu, Die Dai, Hanwen Zhang, Peiyuan Jiang +3 more
top venuecode/data similarity 0.63
Abstract · Accepted at MICCAI 2026. 11 pages, 3 figures, 4 tables. Code: https://github.com/EdvinCecilia/TPR_MultiTeacher

Pre-trained models offer complementary strengths in CT organ segmentation, but their relative accuracy varies across organs and spatial regions. Multi-teacher knowledge distillation can combine these strengths in a single student, yet global or instance-level teacher weights overlook variation within a 3D volume. We propose Task-Performance Routing (TPR), which uses region-wise segmentation errors to determine teacher weights during training without learned routing parameters. In hard regions, TPR favors teachers with lower prediction errors; in easy regions, it uses uniform weights to combine their knowledge. A hierarchical spatial partition provides fine-grained routing in shallow encoder stages and coarse-grained routing in deep stages. Experiments on BTCV, MSD-Liver, and MSD-Pancreas with two teacher pairs and two backbone architectures show higher Dice scores than the individual teachers, adaptive ensembles, and evaluated multi-teacher distillation baselines. On MSD-Pancreas, TPR achieves Dice scores of 65.40% with SwinUNETR and 68.25% with U-Net, compared with 64.38% and 67.45% for the corresponding adaptive ensembles. Inference uses the student alone, with no routing or teacher overhead. Code is available at https://github.com/EdvinCecilia/TPR_MultiTeacher.

0.38

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.62
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21