Spectral Adapters for Segment Anything Model-based Segmentation of Colorectal Liver Metastases in Computed Tomography

Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson

cs.CV ·submitted 2026-09-10 15:26 UTC · v1

Abstract

Accurate segmentation of colorectal liver metastases (CRLM) in contrast-enhanced computed tomography (CT) is important for response assessment, surgical planning, and follow-up. We propose two parameter-efficient spectral adapters for the Segment Anything Model (SAM): the Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA). DiSECT uses singular value decomposition of frozen weights to constrain residual updates to leading spectral directions, while SiGA adds global and input-conditioned gating through a multilayer perceptron. We evaluate these methods on 446 contrast-enhanced CT volumes (355 training, 91 testing) and compare them with LoRA, QLoRA, convolutional adapters (CAD), and a 3D nnU-Net baseline. Experiments consider single-point, three-point, bounding-box, and no-prompt regimes. SiGA achieves the best single-point performance with a Dice score of 0.77, IoU of 0.69, and HD95 of 35.39 mm. Under no-prompt inference, SiGA reaches 0.76 Dice, 0.68 IoU, and 46.76 mm HD95, comparable to the nnU-Net baseline (0.758 Dice). DiSECT uses only 0.14 million trainable parameters. These results show that spectral adapters can efficiently adapt SAM for CRLM segmentation while retaining strong accuracy with limited trainable parameters.

Comment
13 pages, 1 figure, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Parameter-Efficient Fine-Tuning of Foundation Models for Liver Tumor Segmentation in CT

cs.CV ·2026-09-12 ·Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson
publishedcode/data similarity 0.83
Abstract · 9 pages, 2 figures, 1 table. Author manuscript of the published SPIE 2026 proceedings paper; LaTeX reconstructed from the author PDF

We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal liver metastases. We compared Low-Rank Adaptation (LoRA), 4-bit Quantized LoRA (QLoRA), a convolutional adapter (Conv-Adapter), and our Directional Spectral Top-K adapter (DiSCo), training only adapters while freezing the SAM backbone. DiSCo derives spectral bases from singular value decomposition of row-normalized weights and learns rank-gated spectral coefficients, per-output magnitude offsets, and a spectral gain, with optional Top-K rank selection at inference and 0.14 M trainable parameters. We benchmarked five prompting regimes: no prompt, single-point, multi-point, and bounding boxes at intersection over union 0.50 and 0.75. Conv-Adapter and LoRA achieved the highest accuracy (overall Dice 0.793 and 0.792; single-point Dice 0.795 and 0.792; 95th-percentile Hausdorff distance (HD95) 32 mm). QLoRA was close (overall Dice 0.766; single-point Dice 0.768; HD95 36.41 mm), with 0.91 M trainable parameters, 120 ms latency, and 4.9 GB peak memory. DiSCo achieved the highest Dice per million trainable parameters (4.66), with overall Dice 0.653, single-point Dice 0.698, and HD95 49.53 mm. These results show an accuracy-efficiency trade-off and support PEFT for liver tumor segmentation with reduced adaptation costs when compute and labeled data are limited. Code: https://github.com/Ramtin-Mojtahedi/PEFT-SAM-Liver-CT

0.66

LiFUSE: Frequency-Spatial Unified Self-Supervised Pretraining for Liver Disease Analysis on Non-contrast CT

cs.CV cs.AIcs.LG ·2026-10-13 ·Hao Zhang, Yi Huang, Wei Liu, Yuan Gao, Zeju Li +4 more
published similarity 0.67
Abstract · Accepted at the 2026 IEEE International Conference on Bioinformatics and Biomedicine (BIBM 2026)

Given the growing global burden of liver tumors and diffuse liver diseases, non-contrast computed tomography (NCCT) is increasingly used for opportunistic screening because of its low cost and favorable safety profile. However, downstream tasks such as tumor detection and fine-grained disease diagnosis remain challenging due to NCCT's inherently low tissue contrast, lack of hemodynamic enhancement, and complex anatomical background. These limitations make subtle, heterogeneous, and multifocal hepatic lesions difficult to identify. Although large-scale self-supervised pretraining can learn robust representations from unlabeled NCCT scans, conventional voxel-wise reconstruction does not fully exploit the complementary information available in NCCT. Under weak NCCT contrast, low-level intensity patterns become less informative for pathology recognition, limiting the capture of lesion-specific discriminative features. In this paper, we propose the Liver Frequency-Spatial Unified Self-Supervised Pretraining (LiFUSE). The frequency branch applies random band-stop masking and spectrum reconstruction to encourage the model to capture subtle differences between lesions and surrounding tissues, while the spatial branch performs hybrid-granularity masked volumetric reconstruction to accommodate lesions of diverse sizes and morphologies. Finally, a cross-domain consistency scheme couples the spatial and frequency branches, yielding more discriminative representations for hepatic structures and lesions. Extensive experiments on three clinically relevant tasks across internal cohorts and a public target-domain transfer setting show that LiFUSE consistently outperforms strong baselines. These results suggest that unified frequency-spatial learning can improve liver disease analysis on NCCT, highlighting its potential for large-scale screening.

0.16

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

eess.IV cs.CV ·2026-08-28 ·Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals, Anna F. van Herwijnen, Marion Tops-Welten +3 more
published similarity 0.67
Abstract · Accepted as a CaPTion workshop paper at MICCAI 2026

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

0.40

Parameter-Efficient 3D Segmentation of Liver and Liver tumors: Depthwise factorization Scales Better Than Dense Convolution with Spatial Dimensionality

cs.CV cs.LG ·2026-09-27 ·Adham M. Alkhadrawi, Mohammed A. B. Mahmoud
benchmark similarity 0.63
Abstract

Three-dimensional dense convolutional networks are the strongest performers on volumetric medical image segmentation, but their parameter counts scale poorly: moving a dense k x k convolution to k x k x k multiplies its weights by k. We observe that depthwise separable factorization does not share this penalty. Because the cubic kernel term applies only to the depthwise stage while the pointwise projection, which dominates the parameter count, is unchanged, the same architecture grows by 5 % from 2D to 3D where a dense convolutional U-Net grows by 200 %. We exploit this asymmetry to build a 3D U-Net with 536,990 parameters, 24x fewer than an identical dense 3D U-Net. On MSD Task03 Liver (the Medical Segmentation Decathlon liver task, derived from LiTS), evaluated per case under five-fold cross-validation over all 131 public volumes, the model reaches a tumor Dice of 0.577 (95% CI [0.518, 0.633]) and a liver Dice of 0.947 (95% CI [0.941, 0.952]). Its liver Dice exceeds previously reported performance. Its tumor Dice exceeds their low-resolution configuration (0.4701) by 0.107 and their 2D configuration (0.5394), at approximately one twenty-fourth of the parameters and roughly half the in-plane resolution. Trained under identical conditions on a common held-out split, it exceeds a dense 3D U-Net on liver by +0.031 Dice (paired p = 0.006) and on tumor by +0.041 (95 % CI [+0.005, +0.081], paired p = 0.056), suggesting the factorization also acts as a regularizer in the small-data regime characteristic of medical imaging. We further show, on both LiTS and a 2D endoscopy benchmark, that a large fraction of the network's learnable spatial filters can be replaced by fixed shifts at no cost in accuracy, but that replacing all of them is measurably worse, the placement of spatial capacity matters more than its total amount.

0.11

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.63
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28

Unsupervised Adaptation of 3D CT Foundation Models for 3D CBCT Segmentation

cs.CV ·2026-08-27 ·Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
publishedcode/data similarity 0.63
Abstract · Accepted at the EMA4MICCAI workshop at MICCAI 2026. 11 pages, 4 figures, 1 table. Code, trained models, weights, and liver annotations are a…

Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.

0.41

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.63
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

cs.CV cs.LG ·2026-11-17 ·Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
published similarity 0.62
Abstract · 25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower H…

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

0.37