CS Paper Radar

Parameter-Efficient 3D Segmentation of Liver and Liver tumors: Depthwise factorization Scales Better Than Dense Convolution with Spatial Dimensionality

Adham M. Alkhadrawi, Mohammed A. B. Mahmoud

cs.CV cs.LG ·submitted 2026-09-27 01:29 UTC · v1
benchmark

Abstract

Three-dimensional dense convolutional networks are the strongest performers on volumetric medical image segmentation, but their parameter counts scale poorly: moving a dense k x k convolution to k x k x k multiplies its weights by k. We observe that depthwise separable factorization does not share this penalty. Because the cubic kernel term applies only to the depthwise stage while the pointwise projection, which dominates the parameter count, is unchanged, the same architecture grows by 5 % from 2D to 3D where a dense convolutional U-Net grows by 200 %. We exploit this asymmetry to build a 3D U-Net with 536,990 parameters, 24x fewer than an identical dense 3D U-Net. On MSD Task03 Liver (the Medical Segmentation Decathlon liver task, derived from LiTS), evaluated per case under five-fold cross-validation over all 131 public volumes, the model reaches a tumor Dice of 0.577 (95% CI [0.518, 0.633]) and a liver Dice of 0.947 (95% CI [0.941, 0.952]). Its liver Dice exceeds previously reported performance. Its tumor Dice exceeds their low-resolution configuration (0.4701) by 0.107 and their 2D configuration (0.5394), at approximately one twenty-fourth of the parameters and roughly half the in-plane resolution. Trained under identical conditions on a common held-out split, it exceeds a dense 3D U-Net on liver by +0.031 Dice (paired p = 0.006) and on tumor by +0.041 (95 % CI [+0.005, +0.081], paired p = 0.056), suggesting the factorization also acts as a regularizer in the small-data regime characteristic of medical imaging. We further show, on both LiTS and a 2D endoscopy benchmark, that a large fraction of the network's learnable spatial filters can be replaced by fixed shifts at no cost in accuracy, but that replacing all of them is measurably worse, the placement of spatial capacity matters more than its total amount.

Closest papers

Nearest neighbours by meaning across the whole index.

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.73
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

Diffusion-Based Tumor Inpainting for Renal Segmentation under Clinical Data Scarcity

cs.CV ·2026-09-18 ·Ekaterina Sedykh, Salme Ussanov, Dmytro Fedorenko, Dmytro Fishman
similarity 0.72
Abstract

Deep learning segmentation of renal tumors requires large annotated datasets, yet clinical deployments typically offer only a handful of tumor-positive cases from the target site. We propose a diffusion-based inpainting framework that synthesizes anatomically plausible renal tumors within healthy CT scans, requiring no additional annotation, and provide the first systematic comparison of 2D, 2.5D, and full 3D (MAISI) synthesis strategies for this task. Training the diffusion model on public data (KiTS23, KIRC) and evaluating nnU-Net segmentation on a internal cohort across three low-data regimes, we find that 2.5D and 3D augmentation substantially reduce false positives (from $\sim$18--20\% to $\sim$3--6\%) while maintaining Dice, whereas 2D provides no consistent benefit. Crucially, the proposed 2.5D method matches full 3D synthesis on every metric at substantially lower computational cost, indicating that local volumetric consistency alone is sufficient for effective augmentation in data- and resource-scarce clinical settings.

0.12

SAMI3D-DW: Interactive Segmentation of Any 3D Medical Images

cs.CV ·2026-09-22 ·Ping Gong, Shiyuan Su, Fandong Zhang, Xinchen Han, Haowei Sun +2 more
benchmark similarity 0.70
Abstract · 28 pages, 5 figures; replacement version with reordered category-level Dice scores presentation to better reflect clinical conventions., cla…

Interactive segmentation of 3D medical images supports quantitative analysis of anatomical structures and disease while allowing users to specify and refine their targets. Despite substantial progress by nnInteractive and VISTA3D, reliable segmentation across diverse clinical targets remains challenging, particularly for complex anatomical structures and the heterogeneous, long-tailed spectrum of pathology. We present SAMI3D-DW V1 (hereafter SAMI3D-DW), an interactive 3D segmentation model trained on Deepwise's large-scale proprietary medical image datasets. We evaluate the model under simulated user interactions on a CT/MR benchmark comprising 4,326 cases from 219 source datasets, spanning 107 anatomical and pathological categories, organized by a medical taxonomy and evaluated with a category-balanced DSC score. SAMI3D-DW achieves the highest category-macro Dice among evaluated methods in both interaction modes. With one point, it scores 0.5756 versus 0.5316 for nnInteractive, the strongest baseline, rising to 0.7771 versus 0.7495 with five points. With bounding-box initialization, the scores are 0.7129 versus 0.6530. After five corrective clicks, SAMI3D-DW reaches 0.8004 versus 0.7868. For radiologists and clinicians, SAMI3D-DW enables segmentation of complex anatomical structures, including intracranial vessel trees on CT and MR angiography, with a few clicks. In a preliminary in-house comparison involving neurofibromatosis type 1 (NF1), SAMI3D-DW-assisted tumor annotation took minutes per case and approximately one-fifteenth of the time required for manual annotation, highlighting its potential to support volumetric treatment-response assessment.

0.23

VoxelSage: Tool-Augmented 3D CT Analysis and Simulator-Shielded Sequential Resection Planning for Liver Tumors

cs.CV eess.IV ·2026-09-29 ·Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu +1 more
code/data similarity 0.68
Abstract · 21 pages, 10 figures. Technical report. Code at https://github.com/ZJUMAI/VoxelSage

Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dimensional CT volume. Existing tools often handle these steps separately, while language models cannot reliably compute physical measurements from CT. To provide an integrated workflow, we present VoxelSage, a multi-modal system for two- and three-dimensional visualization, liver-tumor analysis, and preoperative resection planning. Its dual-port architecture separates language-model orchestration from image computation: Port A interprets requests and selects skills, while Port B applies them to CT volumes and segmentation masks and returns structured results. Keeping physical measurements in Port B prevents the LLM from computing them directly and reduces the risk of fabricated numerical results. Eight built-in skills support quantitative analysis, visual evidence generation, three-dimensional reconstruction, segmentation refinement, and sequential resection planning; user-defined skills can extend these functions. For sequence planning, a behavior-cloned neural ranker orders candidate resection targets, while a simulator-based shield checks them against predefined constraints. Across 256 unseen simulator scenes, this approach reduced mean simulated time from 34.274 to 33.388 min (0.886 min, 2.59%) and mean simulated blood loss from 300.847 to 183.852 mL (116.995 mL, 38.89%) relative to a deterministic baseline. These results demonstrate system integration and simulator-level performance, not clinical efficacy or safety. The public implementation is available at https://github.com/ZJUMAI/VoxelSage.

0.29

UniPro: Unified Multi-Mode Medical Image Segmentation from 2D Images to 3D Volumes via Propagation

cs.CV ·2026-10-03 ·Bangwei Guo, Yunhe Gao, Meng Ye, Yang Zhou, Difei Gu +3 more
similarity 0.68
Abstract

Medical image segmentation remains fragmented along two axes: segmentation paradigms and data dimensionality. Existing methods are typically developed separately for semantic, in-context, and interactive segmentation, and are further specialized to either native 2D images or 3D volumetric data. In clinical practice, however, segmentation workflows take many forms: a case may be initialized by semantic prediction, reference-guided segmentation, or user interaction. Regardless of how it begins, fine-grained refinement is naturally performed on 2D views; for volumetric scans, such 2D edits must propagate coherently to the rest of the volume. We present UniPro, a unified model that bridges segmentation paradigms and data dimensionality, using propagation to extend 2D segmentation to 3D volumes. Our key insight is that volumetric propagation and in-context segmentation share the same reference-conditioned prediction mechanism, differing only in whether the reference image-mask pairs come from other cases or from previously segmented neighboring slices. Building on this view, UniPro supports semantic, in-context, interactive, and propagation-based segmentation within a single slice-based framework, using class priors, reference exemplars, user clicks, and neighboring-slice predictions as mode-specific conditioning inputs. To improve propagation reliability, UniPro further incorporates bidirectional and 3D supervision to regularize slice-wise propagation beyond per-slice losses. Extensive experiments across diverse modalities and anatomies show that UniPro achieves strong performance across all segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort.

0.13

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.68
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

CIRSeg: Coarse-to-Fine Intensity-Robust Liver Segmentation with Source-Free Continual Test-Time Adaptation

cs.CV ·2026-10-07 ·Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
publishedcode/data similarity 0.68
Abstract · Accepted at the CARE 2026 Workshop at MICCAI 2026

Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease monitoring. However, limited annotated data and scanner- or vendor-dependent intensity variations can cause overfitting and poor generalization to unseen acquisition domains. Moreover, simultaneously achieving robust global localization and precise boundary delineation remains challenging, while predictions may contain isolated false-positive regions outside the main liver component. To address these challenges, we propose CIRSeg, a coarse-to-fine, intensity-robust liver segmentation framework based on nnU-Netv2. CIRSeg combines 3D CutMix with stochastic intensity transfer using either Nyul augmentation or histogram matching to improve robustness to heterogeneous MRI intensities. Its cascaded architecture decouples low-resolution anatomical localization from full-resolution boundary refinement. At inference, source-free test-time adaptation based on confidence-filtered predictions and probability-prior regularization further improves robustness to out-of-distribution inputs. As a final deterministic post-processing step, largest connected component filtering removes isolated false-positive regions. On the CARE 2026 test set, CIRSeg achieves Dice scores of 97.13\% and 97.93\% on the in-domain and unseen-domain subsets, with corresponding HD95 values of 20.18 mm and 11.30 mm, respectively. These results demonstrate consistently accurate segmentation across both in-domain and unseen acquisition settings. The code is available at https://github.com/jingkunchen/MICCAI_CARE_2026

0.28

Unsupervised Anatomical Feature Learning via Diffusion Models: Enhanced Medical Image Segmentation with Denoising Diffusion Probabilistic Models

cs.CV cs.AIcs.LG ·2026-08-26 ·Akshat G, Divyansh Gupta, Shaleen Bhatnagar, Shilpa Ankalaki, Tusar Kanti Mishra
similarity 0.68
Abstract · 15 pages, 5 figures. Submitted for peer review

Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global anatomical structures, leading to boundary delineation failures in low-data regimes. This research paper proposes utilizing unsupervised Denoising Diffusion Probabilistic Models (DDPMs) to extract anatomical features. We train a DDPM on 21 unlabeled abdominal CT scans to learn structural representations, transferring the encoder weights to a downstream segmentation task evaluated on the BTCV multi-organ dataset. Diffusion pretraining significantly improved liver segmentation: Dice increased from $0.75\pm0.36$ to $0.93\pm0.16$ ($p < 5.33\times10^{-26}$, 0.529 Cohen's d), Average Surface Distance (ASD) decreased by 66%, and 95th-percentile Hausdorff Distance (HD95) reduced by 45%. For kidney segmentation, Dice improved from $0.90\pm0.19$ to $0.95\pm0.10$ ($p < 4.01\times10^{-11}$). Multi-organ pooled performance showed a 68% variance reduction and a 74% improvement in boundary precision (Dice $0.95\pm0.07$). Crucially, frozen encoder models retained > 80% of fine-tuned performance without exposure to segmentation labels, proving the existence of learned anatomical priors. In low-data scenarios, diffusion-pretrained models maintained robust performance with only 50% (Dice: 0.92 liver, 0.94 kidney), 25%, and even 10% (Dice: 0.89 liver, 0.71 kidney) of labeled data. Using unlabeled images for diffusion-based pretraining successfully embeds robust anatomical features prior to human supervision, transforming U-Nets into anatomy-aware systems.

0.21