CS Paper Radar

VoxelSage: Tool-Augmented 3D CT Analysis and Simulator-Shielded Sequential Resection Planning for Liver Tumors

Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu, Haochao Ying

cs.CV eess.IV ·submitted 2026-09-29 14:15 UTC · v1
code/data

Abstract

Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dimensional CT volume. Existing tools often handle these steps separately, while language models cannot reliably compute physical measurements from CT. To provide an integrated workflow, we present VoxelSage, a multi-modal system for two- and three-dimensional visualization, liver-tumor analysis, and preoperative resection planning. Its dual-port architecture separates language-model orchestration from image computation: Port A interprets requests and selects skills, while Port B applies them to CT volumes and segmentation masks and returns structured results. Keeping physical measurements in Port B prevents the LLM from computing them directly and reduces the risk of fabricated numerical results. Eight built-in skills support quantitative analysis, visual evidence generation, three-dimensional reconstruction, segmentation refinement, and sequential resection planning; user-defined skills can extend these functions. For sequence planning, a behavior-cloned neural ranker orders candidate resection targets, while a simulator-based shield checks them against predefined constraints. Across 256 unseen simulator scenes, this approach reduced mean simulated time from 34.274 to 33.388 min (0.886 min, 2.59%) and mean simulated blood loss from 300.847 to 183.852 mL (116.995 mL, 38.89%) relative to a deterministic baseline. These results demonstrate system integration and simulator-level performance, not clinical efficacy or safety. The public implementation is available at https://github.com/ZJUMAI/VoxelSage.

Comment
21 pages, 10 figures. Technical report. Code at https://github.com/ZJUMAI/VoxelSage

Closest papers

Nearest neighbours by meaning across the whole index.

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.73
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

Pretrained, Curriculum-Tuned, and Ensembled: A Tracer-Aware Interactive Segmentation Pipeline for AutoPET V

cs.CV cs.AI ·2026-08-31 ·Xinglong Liang, Chunyao Lu, Tianyu Zhang, Jiaju Huang, Tao Tan +2 more
code/data similarity 0.71
Abstract

Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to sparse corrective scribbles during inference. This setting is particularly challenging because tracer distributions, physiological uptake patterns, lesion appearance, and acquisition characteristics differ substantially between FDG and PSMA studies. We present TRIAGE, Tracer-aware Refinement via Interactive Anatomy-Guided sEgmentation. The core backbone is a 3D STU-Net initialized through masked autoencoding pre-training with an asynchronous masking strategy, aiming to learn transferable anatomical and cross-modal representations before task-specific fine-tuning. In parallel, we train an auxiliary organ segmentation model whose predictions provide explicit anatomical context and help distinguish physiological uptake from malignant lesions. A dedicated tracer classifier first routes each study to an FDG- or PSMA-specific branch. Within each branch, a first-stage segmentation model consumes CT, PET, and organ context to generate an initial lesion mask. The initial prediction is then combined with cumulative foreground/background scribbles and refined by a second interactive segmentation network. The FDG and PSMA branches share the same overall processing pipeline but are trained independently to account for tracer-specific appearance and error modes. We additionally employ curriculum-style training and model ensembling to improve robustness across interaction steps and heterogeneous cohorts. Experiments are conducted using the official AutoPET V data and ten-fold split; quantitative results, ablations, and final test-set performance are left as placeholders to be completed after the challenge evaluation. Code: https://github.com/Liiiii2101/AUTOPET2026-MEDAI.

0.24

UniPro: Unified Multi-Mode Medical Image Segmentation from 2D Images to 3D Volumes via Propagation

cs.CV ·2026-10-03 ·Bangwei Guo, Yunhe Gao, Meng Ye, Yang Zhou, Difei Gu +3 more
similarity 0.69
Abstract

Medical image segmentation remains fragmented along two axes: segmentation paradigms and data dimensionality. Existing methods are typically developed separately for semantic, in-context, and interactive segmentation, and are further specialized to either native 2D images or 3D volumetric data. In clinical practice, however, segmentation workflows take many forms: a case may be initialized by semantic prediction, reference-guided segmentation, or user interaction. Regardless of how it begins, fine-grained refinement is naturally performed on 2D views; for volumetric scans, such 2D edits must propagate coherently to the rest of the volume. We present UniPro, a unified model that bridges segmentation paradigms and data dimensionality, using propagation to extend 2D segmentation to 3D volumes. Our key insight is that volumetric propagation and in-context segmentation share the same reference-conditioned prediction mechanism, differing only in whether the reference image-mask pairs come from other cases or from previously segmented neighboring slices. Building on this view, UniPro supports semantic, in-context, interactive, and propagation-based segmentation within a single slice-based framework, using class priors, reference exemplars, user clicks, and neighboring-slice predictions as mode-specific conditioning inputs. To improve propagation reliability, UniPro further incorporates bidirectional and 3D supervision to regularize slice-wise propagation beyond per-slice losses. Extensive experiments across diverse modalities and anatomies show that UniPro achieves strong performance across all segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort.

0.13

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.68
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Parameter-Efficient 3D Segmentation of Liver and Liver tumors: Depthwise factorization Scales Better Than Dense Convolution with Spatial Dimensionality

cs.CV cs.LG ·2026-09-27 ·Adham M. Alkhadrawi, Mohammed A. B. Mahmoud
benchmark similarity 0.68
Abstract

Three-dimensional dense convolutional networks are the strongest performers on volumetric medical image segmentation, but their parameter counts scale poorly: moving a dense k x k convolution to k x k x k multiplies its weights by k. We observe that depthwise separable factorization does not share this penalty. Because the cubic kernel term applies only to the depthwise stage while the pointwise projection, which dominates the parameter count, is unchanged, the same architecture grows by 5 % from 2D to 3D where a dense convolutional U-Net grows by 200 %. We exploit this asymmetry to build a 3D U-Net with 536,990 parameters, 24x fewer than an identical dense 3D U-Net. On MSD Task03 Liver (the Medical Segmentation Decathlon liver task, derived from LiTS), evaluated per case under five-fold cross-validation over all 131 public volumes, the model reaches a tumor Dice of 0.577 (95% CI [0.518, 0.633]) and a liver Dice of 0.947 (95% CI [0.941, 0.952]). Its liver Dice exceeds previously reported performance. Its tumor Dice exceeds their low-resolution configuration (0.4701) by 0.107 and their 2D configuration (0.5394), at approximately one twenty-fourth of the parameters and roughly half the in-plane resolution. Trained under identical conditions on a common held-out split, it exceeds a dense 3D U-Net on liver by +0.031 Dice (paired p = 0.006) and on tumor by +0.041 (95 % CI [+0.005, +0.081], paired p = 0.056), suggesting the factorization also acts as a regularizer in the small-data regime characteristic of medical imaging. We further show, on both LiTS and a 2D endoscopy benchmark, that a large fraction of the network's learnable spatial filters can be replaced by fixed shifts at no cost in accuracy, but that replacing all of them is measurably worse, the placement of spatial capacity matters more than its total amount.

0.11

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.68
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

An Agentic AI Workflow for Liver Lesion Segmentation and Structured Radiology Reporting

cs.CV cs.LG ·2026-10-25 ·Fatma Ahmed Mansour, Rahatara Ferdousi, Zyad Medhat Mahmoud Ashor, Manar Fathy Elshenawy, Ibrahim Shehaby +2 more
similarity 0.68
Abstract

Despite advances in automated liver lesion segmentation, a gap remains between image-derived predictions and clinically interpretable radiology reports. Bridging this gap requires quantitative measurements that are both reproducible and traceable. We present an evidence-grounded agentic AI framework that connects liver and lesion segmentation with deterministic quantification and structured reporting. TotalSegmentator-based nnU-Net models delineate the liver, Couinaud segments, and lesions, while computational tools extract volumes, dimensions, counts, and anatomical locations. A large language model (LLM) organizes these measurements into a predefined reporting schema, with numerical consistency checks against source measurements. On 51 LiTS cases, the segmentation stage achieved a liver Dice score of 0.947, lesion sensitivity of 75.6%, and positive predictive value of 68.9%. Exploratory screening of 25,494 MERLIN reports identified 10,208 (40.0%) with liver-related abnormalities. By connecting quantitative imaging evidence with agentic report generation, this work takes a step toward human-centered medical AI that prioritizes traceability and clinical relevance.

0.23

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.67
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12