CS Paper Radar

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali

cs.CV cs.AIcs.HC ·submitted 2026-10-16 20:42 UTC · v1

Abstract

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

Comment
10 pages

Closest papers

Nearest neighbours by meaning across the whole index.

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.75
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.72
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

LapaTrack-3D: 6 DoF pre-operative shape tracking for laparoscopic surgery

cs.RO cs.CV ·2026-09-17 ·Jingwei Song, Javid Hussain Jakir, Ray Zhang, Wenwei Zhang, Hao Zhou +2 more
top venue similarity 0.71
Abstract · This paper has been accepted by IEEE Transactions on Medical Robotics and Bionics (T-MRB)

This work proposes a real-time 6 Degree-of-Freedom (6 DoF) tracking algorithm for monocular laparoscopic surgery. It provides alignment between intra-operative video and pre-operative data (e.g., CT). The 6 DoF tracking offers a solution for accurately locating the internal anatomy of the target organ despite the lack of tactile feedback and transparency. The ORB-SLAM2 framework is adopted and modified for prior-based 3D tracking with four major modifications. First, the primitive 3D shape is used for fast initialization of the ORB-SLAM2 monocular mode. Second, a pseudo-segmentation strategy is employed to separate the target organ from the background for tracking. Third, the 3D shape is incorporated as a geometric prior in its pose graph optimization. Fourth, the Multi-Scale Retinex with Chromaticity Preservation (MSRCP) algorithm is leveraged and modified for image enhancement in challenging illumination scenarios. In-vivo and ex-vivo experiments validate that LapaTrack-3D provides robust 3D tracking and effectively handles typical challenges such as poor illumination, fast motion, out-of-field-of-view scenarios, partial visibility, and ``organ-background'' relative motion. LapaTrack-3D achieves a processing rate of 13 Hz for 1280*720 pixel video.

0.40

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.71
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

SurgTAP-3D: A Large-Scale Cross-Surgery Video Dataset with Contact-Aware 3D Motion Tracking

cs.CV cs.RO ·2026-11-08 ·Jiaxin Guo, Wenzhen Dong, Taoyu Wu, Haomin Kuang, Mengya Xu +7 more
publishedbenchmark similarity 0.70
Abstract · Accepted to IEEE Transactions on Robotics (T-RO)

Understanding 3D scene dynamics in minimally invasive surgery (MIS) is a fundamental step toward physically intelligent and autonomous surgical systems. However, existing public datasets offer limited scalability and diversity in real-world clinical scenarios. Moreover, annotations typically focus on either tissue or instruments alone, overlooking tool-tissue interactions. This gap limits applications such as augmented reality guidance and autonomous surgery driven by vision-language-action (VLA) models or world models, which demand large-scale, high-quality 3D supervision. In this work, we construct SurgTAP-3D, a large-scale in-vivo pseudo-3D surgical motion tracking dataset and benchmark, comprising 520K frames, 4,549 action clips, and 1.4M 2D/3D point trajectories from diverse robotic and manual procedures under unified action categories. To make annotation scalable, we design a unified framework for surgical 3D point tracking that converts uncalibrated monocular surgical videos into structured 4D annotations through contact-region prompting, active-tool segmentation, dynamic bundle adjustment, and global 4D refinement. This pipeline adapts foundation priors to surgical videos and produces temporally consistent trajectories, pseudo-scale geometry, camera poses, and instrument masks. The dataset captures realistic challenges inherent to surgical environments, including occlusions, smoke, bleeding, and rapid instrument motion. We establish a comprehensive benchmark on SurgPose, SurgT, and STIR, covering both instrument and tissue tracking. We demonstrate instrument displacement estimation, deformable surface reconstruction, and foundation-model fine-tuning. Extensive experiments and analysis demonstrate the effectiveness of our dataset and annotation framework for 3D surgical point tracking, reconstruction, and surgical action understanding. Homepage: https://wrld.github.io/surgtap-3d/

0.34

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

cs.CV physics.med-ph ·2026-10-25 ·Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz +4 more
code/data similarity 0.70
Abstract

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

0.24

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation

cs.CV ·2026-11-01 ·Lixing Tan, Hongye Hao, Tianrun Gu, Qing Xia, Yuting Guo +2 more
similarity 0.69
Abstract

Registering intraoperative Ultrasound (US) bone-surface point clouds to preoperative Computed Tomography (CT) models can support radiation-free orthopedic navigation. Differences in imaging physics produce distinct surface sampling patterns, complicating cross-modal feature matching. Bone strongly reflects ultrasound and casts an acoustic shadow, so US captures only the probe-facing bone surface and leaves most CT points unmatched. This partial coverage makes correspondences ambiguous on near-symmetric bones. We propose CUFormer, a modality-aware registration framework. We introduce a Modality-Aware Transformer (MAT) that encodes input modality through identity embeddings and updates features through modality-specific adapters within a shared geometric matcher. We model imaging visibility and use predicted reference-side visibility to weight coarse and fine correspondences. CUFormer achieves the lowest mean registration errors among evaluated methods on two CT-US datasets, UltraBones100k and UltraBonesHip, and the CT-RGB-D dataset SpineDepth. On UltraBones100k, it reaches mean rotation error 4.53$^\circ$, translation error 3.19\,mm, and Root Mean Squared Error (RMSE) 2.54\,mm, reducing RMSE by 65.8\% relative to the best-performing baseline by this metric. These results demonstrate CUFormer's effectiveness in aligning partial bone surfaces with preoperative CT across anatomical sites.

0.24

Colon3R: Cross-Domain 3D Reconstruction from Monocular Colonoscopic Video

cs.CV cs.RO ·2026-09-21 ·Zhihao Xing, Yingyu Wang, Liang Zhao, Shoudong Huang
code/data similarity 0.69
Abstract

Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not enough in-vivo labeled data available to adapt geometry foundation models to clinical colonoscopy. We present Colon3R, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations. Unlike source-only fine-tuning, which learns only from phantom and simulated data, Colon3R directly exploits unlabeled in-vivo video through teacher-derived cross-view supervision. Our proposed hierarchical quasi-rigid reliability selects reliable supervision at the sequence, directed-pair, and pixel levels, while source-preserving adaptation retains the learned coupled geometry during target-domain adaptation. Extensive experiments demonstrate that our method achieves superior overall performance over state-of-the-art approaches in depth, pointmap, and camera pose estimation. Qualitative comparisons on real in-vivo colonoscopy further show substantially more complete and geometrically consistent reconstructions than competing methods under clinical domain shift. The code is publicly available at https://github.com/vglx/Colon3R.

0.29