CS Paper Radar

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon, Humphrey W. Chow, Francisco Vasconcelos, Sophia Bano, Adam Schmidt, Omid Mohareri

cs.CV cs.RO ·submitted 2026-11-03 12:06 UTC · v1
top venuebenchmarkcode/data

Abstract

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

Comment
Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed
Journal ref
Computer Vision - ECCV 2026, LNCS 17078, pp. 313-332, Springer, 2026
DOI
10.1007/978-3-032-37393-9_19

Closest papers

Nearest neighbours by meaning across the whole index.

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.80
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.

0.33

PICO: Projection-Informed Consistency Optimisation for 6DoF Surgical Tool Pose Estimation

cs.CV ·2026-09-25 ·Lucy Fothergill, Pietro Valdastri, Dominic Jones, Duygu Sarikaya
published similarity 0.77
Abstract

Purpose: Accurate 6 DoF pose estimation of surgical tools is critical for automa- tion, robotic proprioception, and safe interaction with the tissue operated on. Kinematics-based approaches suffer from accumulated errors due to the cable- driven nature of robotic arms, while vision-based methods often rely on external markers or trackers. Although more recent vision-based advances have been pro- posed, these two-stage pose estimation methods often lack real-time robustness due to accumulated errors and computational overhead. Methods: We propose a novel end-to-end trainable model, PICO. Our model employs a multi-task learning architecture to predict segmentation and depth maps, alongside regression of translation and rotation parameters. We define two proxy tasks that enforce geometric consistency in both 2D and 3D spaces, improving accuracy and robustness. For this, we propose a projection loss, and a point-to-point loss. Results: We evaluate our method on the SurgRIPE dataset, benchmarking its performance against state-of-the-art approaches using standard 6DoF pose esti- mation metrics. Our results demonstrate consistently strong performance across all four subsets, specifically in rotation, ranking second even under occlusion. It also demonstrates comparable translational performance, remaining competitive, especially in occluded cases. Conclusion: PICO demonstrates the effectiveness of multi-task learning and geometry-aware proxy tasks for robust and reliable surgical tool pose estimation, especially in occluded scenarios, highlighting potential for future applications.

0.33

Surgical Kinematics from Monocular Video with Learned Articulated Motion Constraints

cs.CV cs.RO ·2026-09-23 ·Mehmet Kerem Turkcan, Soham Samal, Zoran Kostic
benchmark similarity 0.77
Abstract

Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder and temporal convolutional heads integrate this representation with mask geometry, monocular depth and visual state estimates from arm-specific multilayer regression networks. Our position branch predicts displacement magnitude and direction separately to preserve traveled distance. We fit trajectories to predicted state observations and motion increments by differentiable weighted least squares, expressing quaternion observations relative to cumulative predicted rotations to obtain a quadratic orientation objective. We evaluate reconstruction across 2,802 Open-H episodes. Compared with LiveMAE on the main Open-H benchmark, our method reduces path-length mean absolute error from 0.45 to 0.34\,cm and increases temporal mean average precision for motion segmentation from 44.54\% to 54.44\%.

0.20

SurgTAP-3D: A Large-Scale Cross-Surgery Video Dataset with Contact-Aware 3D Motion Tracking

cs.CV cs.RO ·2026-11-08 ·Jiaxin Guo, Wenzhen Dong, Taoyu Wu, Haomin Kuang, Mengya Xu +7 more
publishedbenchmark similarity 0.77
Abstract · Accepted to IEEE Transactions on Robotics (T-RO)

Understanding 3D scene dynamics in minimally invasive surgery (MIS) is a fundamental step toward physically intelligent and autonomous surgical systems. However, existing public datasets offer limited scalability and diversity in real-world clinical scenarios. Moreover, annotations typically focus on either tissue or instruments alone, overlooking tool-tissue interactions. This gap limits applications such as augmented reality guidance and autonomous surgery driven by vision-language-action (VLA) models or world models, which demand large-scale, high-quality 3D supervision. In this work, we construct SurgTAP-3D, a large-scale in-vivo pseudo-3D surgical motion tracking dataset and benchmark, comprising 520K frames, 4,549 action clips, and 1.4M 2D/3D point trajectories from diverse robotic and manual procedures under unified action categories. To make annotation scalable, we design a unified framework for surgical 3D point tracking that converts uncalibrated monocular surgical videos into structured 4D annotations through contact-region prompting, active-tool segmentation, dynamic bundle adjustment, and global 4D refinement. This pipeline adapts foundation priors to surgical videos and produces temporally consistent trajectories, pseudo-scale geometry, camera poses, and instrument masks. The dataset captures realistic challenges inherent to surgical environments, including occlusions, smoke, bleeding, and rapid instrument motion. We establish a comprehensive benchmark on SurgPose, SurgT, and STIR, covering both instrument and tissue tracking. We demonstrate instrument displacement estimation, deformable surface reconstruction, and foundation-model fine-tuning. Extensive experiments and analysis demonstrate the effectiveness of our dataset and annotation framework for 3D surgical point tracking, reconstruction, and surgical action understanding. Homepage: https://wrld.github.io/surgtap-3d/

0.34

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.76
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training

cs.RO cs.CV ·2026-10-04 ·Hanyang Hu, Zekai Liang, Florian Richter, Michael C. Yip
similarity 0.75
Abstract

Efficient and robust tracking of surgical robotic instruments is important for robot-assisted minimally invasive surgery, yet remains challenging due to the complexity of surgical scenes and the unconventional geometry of surgical instruments. Keypoint-based approaches are efficient, but their performance depends on reliable feature detection. Improving these detectors with real-world supervision is difficult because accurate real-world annotations are costly to obtain at scale. To address this limitation, we introduce a tracker-guided self-training framework that adapts a model pretrained on synthetic images to unlabeled real-world videos. Given measured robot joint states, an uncertainty-aware EKF recursively corrects the instrument pose and the observable joint angles by comparing projected model features with detected keypoints, shaft boundaries, and mask-derived cues. An RTS smoother subsequently refines the resulting trajectory, which is projected into pseudo-labels for fine-tuning the feature detector without laborious pose annotations. Experiments on real-world videos demonstrate consistent improvements from self-training across all evaluated keypoint metrics, and the resulting model outperforms prior approaches in both accuracy and runtime. The code and data will be released upon publication.

0.26

4D Triangle Splatting Reconstruction of Dynamic Endoscopic Scenes from Monocular Videos

cs.CV cs.RO ·2026-11-01 ·Laura Salort-Benejam, Stamatia Giannarou, Antonio Agudo
similarity 0.74
Abstract · Off-Grid; MICCAIW 2026

Robust 4D reconstruction of deformable endoscopic scenes from monocular videos remains challenging due to non-rigid tissue deformation, illumination changes, occlusions, and unknown camera trajectories. Reliable dynamic reconstruction of endoscopies could significantly enhance visualization, diagnostic accuracy and intraoperative guidance of minimally invasive procedures. We propose SurgicalTS, a self-supervised triangle-splatting framework for dynamic endoscopic scene reconstruction from static monocular cameras. The scene is represented by a canonical set of triangles jointly optimized with a deformation network. We introduce a quaternion-based deformation model, an improved color parametrization, spatio-temporal priors, and a redefined initialization strategy that improves completeness under occlusions. Extensive evaluation on challenging in-vivo endoscopy videos from diverse procedures shows that SurgicalTS successfully models soft-tissue deformations and tool-tissue interactions over time, while consistently outperforming state-of-the-art methods. Our method also reduces training times while maintaining competitive geometric and photometric accuracy results, highlighting the effectiveness of quaternion-based deformation modelling with physical consistency for robust and efficient 4D reconstruction of endoscopic scenes.

0.06

EndoPrior-GS: Dynamic Endoscopic Reconstruction with a Joint Texture Prior

cs.CV ·2026-09-29 ·Jiaqi Huang, Shidong Wang, Tong Xin, Kabita Adhikari
publishedbenchmarkcode/data similarity 0.73
Abstract · Accepted at ACCV 2026. Code: https://github.com/jiaqi-huang-77/EndoPrior-GS

Dynamic endoscopic reconstruction is fundamental to robotic surgery and computer-assisted interventions. While 3D Gaussian Splatting (3DGS) realises real-time rendering, its application to deformable intraoperative environments remains constrained by spurious geometry and varying illuminations. To address these limitations, we introduce EndoPrior-GS, a novel pipeline that explicitly couples frame-extracted vision heuristics and estimated depth maps. EndoPrior-GS derives a joint texture prior from a tool-filtered valid tissue mask, a non-specular photometric filter, and anatomical structural salience, yielding a probability map that guides primitive initialisation and subsequent density control. The prior is further extended to the temporal domain through a texture-aware term that dynamically weighs pairwise primitive contributions during training. We conduct extensive experiments on benchmark datasets EndoNeRF and SCARED, and the obtained results show that our method EndoPrior-GS reduces Flow Error by 27.7% and 25.8% over the representative approaches while preserving competitive rendering quality and real-time rendering speed. Our project website is available at https://jiaqi-huang-77.github.io/EndoPrior-GS/.

0.37