CS Paper Radar

Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training

Hanyang Hu, Zekai Liang, Florian Richter, Michael C. Yip

cs.RO cs.CV ·submitted 2026-10-04 19:59 UTC · v1

Abstract

Efficient and robust tracking of surgical robotic instruments is important for robot-assisted minimally invasive surgery, yet remains challenging due to the complexity of surgical scenes and the unconventional geometry of surgical instruments. Keypoint-based approaches are efficient, but their performance depends on reliable feature detection. Improving these detectors with real-world supervision is difficult because accurate real-world annotations are costly to obtain at scale. To address this limitation, we introduce a tracker-guided self-training framework that adapts a model pretrained on synthetic images to unlabeled real-world videos. Given measured robot joint states, an uncertainty-aware EKF recursively corrects the instrument pose and the observable joint angles by comparing projected model features with detected keypoints, shaft boundaries, and mask-derived cues. An RTS smoother subsequently refines the resulting trajectory, which is projected into pseudo-labels for fine-tuning the feature detector without laborious pose annotations. Experiments on real-world videos demonstrate consistent improvements from self-training across all evaluated keypoint metrics, and the resulting model outperforms prior approaches in both accuracy and runtime. The code and data will be released upon publication.

Closest papers

Nearest neighbours by meaning across the whole index.

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.75
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

SurgTAP-3D: A Large-Scale Cross-Surgery Video Dataset with Contact-Aware 3D Motion Tracking

cs.CV cs.RO ·2026-11-08 ·Jiaxin Guo, Wenzhen Dong, Taoyu Wu, Haomin Kuang, Mengya Xu +7 more
publishedbenchmark similarity 0.74
Abstract · Accepted to IEEE Transactions on Robotics (T-RO)

Understanding 3D scene dynamics in minimally invasive surgery (MIS) is a fundamental step toward physically intelligent and autonomous surgical systems. However, existing public datasets offer limited scalability and diversity in real-world clinical scenarios. Moreover, annotations typically focus on either tissue or instruments alone, overlooking tool-tissue interactions. This gap limits applications such as augmented reality guidance and autonomous surgery driven by vision-language-action (VLA) models or world models, which demand large-scale, high-quality 3D supervision. In this work, we construct SurgTAP-3D, a large-scale in-vivo pseudo-3D surgical motion tracking dataset and benchmark, comprising 520K frames, 4,549 action clips, and 1.4M 2D/3D point trajectories from diverse robotic and manual procedures under unified action categories. To make annotation scalable, we design a unified framework for surgical 3D point tracking that converts uncalibrated monocular surgical videos into structured 4D annotations through contact-region prompting, active-tool segmentation, dynamic bundle adjustment, and global 4D refinement. This pipeline adapts foundation priors to surgical videos and produces temporally consistent trajectories, pseudo-scale geometry, camera poses, and instrument masks. The dataset captures realistic challenges inherent to surgical environments, including occlusions, smoke, bleeding, and rapid instrument motion. We establish a comprehensive benchmark on SurgPose, SurgT, and STIR, covering both instrument and tissue tracking. We demonstrate instrument displacement estimation, deformable surface reconstruction, and foundation-model fine-tuning. Extensive experiments and analysis demonstrate the effectiveness of our dataset and annotation framework for 3D surgical point tracking, reconstruction, and surgical action understanding. Homepage: https://wrld.github.io/surgtap-3d/

0.34

PICO: Projection-Informed Consistency Optimisation for 6DoF Surgical Tool Pose Estimation

cs.CV ·2026-09-25 ·Lucy Fothergill, Pietro Valdastri, Dominic Jones, Duygu Sarikaya
published similarity 0.73
Abstract

Purpose: Accurate 6 DoF pose estimation of surgical tools is critical for automa- tion, robotic proprioception, and safe interaction with the tissue operated on. Kinematics-based approaches suffer from accumulated errors due to the cable- driven nature of robotic arms, while vision-based methods often rely on external markers or trackers. Although more recent vision-based advances have been pro- posed, these two-stage pose estimation methods often lack real-time robustness due to accumulated errors and computational overhead. Methods: We propose a novel end-to-end trainable model, PICO. Our model employs a multi-task learning architecture to predict segmentation and depth maps, alongside regression of translation and rotation parameters. We define two proxy tasks that enforce geometric consistency in both 2D and 3D spaces, improving accuracy and robustness. For this, we propose a projection loss, and a point-to-point loss. Results: We evaluate our method on the SurgRIPE dataset, benchmarking its performance against state-of-the-art approaches using standard 6DoF pose esti- mation metrics. Our results demonstrate consistently strong performance across all four subsets, specifically in rotation, ranking second even under occlusion. It also demonstrates comparable translational performance, remaining competitive, especially in occluded cases. Conclusion: PICO demonstrates the effectiveness of multi-task learning and geometry-aware proxy tasks for robust and reliable surgical tool pose estimation, especially in occluded scenarios, highlighting potential for future applications.

0.33

S3-Tracker: Self-Supervised Surgical Tissue Tracking With Contrastive Random Walks

cs.CV cs.LGcs.RO ·2026-09-13 ·Jiaming Zhang, Zijian Wu, Mehran Armand, Septimiu Salcudean
published similarity 0.73
Abstract

Robust point tracking in endoscopic videos is essential for computer-assisted intervention and autonomous robotic surgery, enabling continuous registration between intraoperative video and preoperative imaging despite soft tissue deformation. However, supervised tracking methods depend on large annotated datasets, while surgical conditions make reliable trajectory annotation challenging. We propose a self-supervised Track-Any-Point approach that learns from unlabeled surgical videos by establishing global pixel correspondences and inferring point trajectories through contrastive random walks. Trained without annotations, our method achieves performance comparable to existing semi-supervised approaches while implicitly handling tissue deformation. These findings demonstrate the feasibility of self-supervised point tracking in surgical environments and its potential to reduce reliance on annotated data.

0.22

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.69
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

Semantic-Coupled Perception Framework for Autonomous Laparoscope Control

cs.RO eess.SY ·2026-10-25 ·Enduo Zhao, Fangzhou Li, Yujie Zhu, Sicheng Lu, Fang Chen +2 more
benchmark similarity 0.68
Abstract · 8 pages, 5 figures. Submitted to IEEE Robotics and Automation Letters (RA-L) for possible publication

In minimally invasive surgery (MIS), maintaining an appropriate field of view (FoV) is essential for surgical safety and efficiency. However, conventional autonomous laparoscope control methods often treat visual tracking and surgical phase recognition independently, limiting robustness under occlusion, entity overlap, and camera motion. This paper proposes a closed-loop autonomous laparoscope control framework that couples real-time surgical phase recognition with camera-motion-compensated visual perception. By exploiting phase-dependent relationships among surgical entities, the framework improves target state estimation under challenging visual conditions, supporting task-aware autonomous FoV control. Experiments on benchmark datasets evaluate the proposed framework in surgical phase recognition and target tracking, including scenarios involving occlusion and entity overlap. Phantom experiments further demonstrate the feasibility of autonomous FoV control, showing improved target visibility and task execution performance compared with fixed-FoV control. These results highlight the potential of incorporating task-level semantics into visual state estimation for autonomous laparoscope guidance.

0.18

STEP: Surgical Point Tracking from Sparse Endpoints and Pseudo-trajectories

cs.CV ·2026-10-22 ·Bing Fan, Anwesa Choudhuri, Zhongpai Gao, Meng Zheng, Benjamin Planche +3 more
similarity 0.68
Abstract

Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obtain. We present STEP, a two-stage framework that learns from surgical video and sparse physical endpoints. First, a frozen offline teacher generates candidate trajectories, and temporal reversibility and stereo consistency select dense supervision for a causal student. Second, a robust physical endpoint loss anchors terminal correspondence, while a round-trip loss constrains temporal consistency. A gradient-free prefix exposes training to accumulated drift, while a final differentiable window bounds activation memory. The trained tracker processes a single RGB stream with fixed weights. In STIR-to-VL-SurgPT transfer, temporal-stereo union selection reduces endpoint error by 7.0% relative to unfiltered trajectories. On a post-hoc diagnostic of 29 VL-SurgPT clips excluded from the endpoint-training manifest, STEP reduces endpoint error from 31.52 to 16.80 pixels relative to dense-label fine-tuning. These results support combining curated trajectories with physical observations to train surgical point trackers.

0.17

From Presence Labels to Bounding Boxes: Can Multimodal Large Language Models Scale Surgical Instrument Localization?

cs.CV ·2026-10-25 ·Mohamed Hamdy, Muraam Abdel-Ghani, Fatmaelzahraa Ahmed, Sifna Nasar, Mariam Ahmed +3 more
similarity 0.68
Abstract

Spatial localization of surgical instruments through bounding-box annotations is a foundational component of surgical scene understanding, supporting detection, tracking, interaction analysis, and grounded vision-language applications. Yet existing annotations often cover selected frames, video subsets, or dataset variants rather than complete procedures. Manual extension is time-consuming and expert-dependent. Additionally, weakly supervised and detector-based pseudo-labels require task-specific training and may be imprecise. In this study, we design a scalable MLLM-based annotation framework that converts surgical frames and existing instrument-presence labels into accurate bounding boxes, and systematically analyze its reliability, cost, and design sensitivity. We instantiate the framework using six MLLMs and a multi-call configuration on laparoscopic cholecystectomy in Cholec80. Using a carefully designed stratification scheme, two annotators independently label 1,000 frames, and an expert surgeon reviews one annotation set to establish the reference. Results show that instrument-set F1 ranges from 88.2 to 92.7,whereas mIoU ranges from 0.180 to 0.735, showing that comparable recognition can conceal large localization differences. A structured multi-stage annotation pipeline achieves 0.784 mIoU, compared with 0.735 for the best single-call baseline and 0.814 human-human agreement. Using the best accuracy pipeline, we create and publicly release SurgBox, a spatial extension of Cholec80 comprising 285,977 bounding boxes across all 184,498 annotated frames from the 80 videos. The annotations and human references are made available on GitHub

0.23