CS Paper Radar

S3-Tracker: Self-Supervised Surgical Tissue Tracking With Contrastive Random Walks

Jiaming Zhang, Zijian Wu, Mehran Armand, Septimiu Salcudean

cs.CV cs.LGcs.RO ·submitted 2026-09-13 06:17 UTC · v1
published

Abstract

Robust point tracking in endoscopic videos is essential for computer-assisted intervention and autonomous robotic surgery, enabling continuous registration between intraoperative video and preoperative imaging despite soft tissue deformation. However, supervised tracking methods depend on large annotated datasets, while surgical conditions make reliable trajectory annotation challenging. We propose a self-supervised Track-Any-Point approach that learns from unlabeled surgical videos by establishing global pixel correspondences and inferring point trajectories through contrastive random walks. Trained without annotations, our method achieves performance comparable to existing semi-supervised approaches while implicitly handling tissue deformation. These findings demonstrate the feasibility of self-supervised point tracking in surgical environments and its potential to reduce reliance on annotated data.

Journal ref
J. Zhang et al. Proc. 18th Hamlyn Symp. Med. Robot. (2026) 25-26;
DOI
10.31256/HSMR26.13

Closest papers

Nearest neighbours by meaning across the whole index.

SurgTAP-3D: A Large-Scale Cross-Surgery Video Dataset with Contact-Aware 3D Motion Tracking

cs.CV cs.RO ·2026-11-08 ·Jiaxin Guo, Wenzhen Dong, Taoyu Wu, Haomin Kuang, Mengya Xu +7 more
publishedbenchmark similarity 0.77
Abstract · Accepted to IEEE Transactions on Robotics (T-RO)

Understanding 3D scene dynamics in minimally invasive surgery (MIS) is a fundamental step toward physically intelligent and autonomous surgical systems. However, existing public datasets offer limited scalability and diversity in real-world clinical scenarios. Moreover, annotations typically focus on either tissue or instruments alone, overlooking tool-tissue interactions. This gap limits applications such as augmented reality guidance and autonomous surgery driven by vision-language-action (VLA) models or world models, which demand large-scale, high-quality 3D supervision. In this work, we construct SurgTAP-3D, a large-scale in-vivo pseudo-3D surgical motion tracking dataset and benchmark, comprising 520K frames, 4,549 action clips, and 1.4M 2D/3D point trajectories from diverse robotic and manual procedures under unified action categories. To make annotation scalable, we design a unified framework for surgical 3D point tracking that converts uncalibrated monocular surgical videos into structured 4D annotations through contact-region prompting, active-tool segmentation, dynamic bundle adjustment, and global 4D refinement. This pipeline adapts foundation priors to surgical videos and produces temporally consistent trajectories, pseudo-scale geometry, camera poses, and instrument masks. The dataset captures realistic challenges inherent to surgical environments, including occlusions, smoke, bleeding, and rapid instrument motion. We establish a comprehensive benchmark on SurgPose, SurgT, and STIR, covering both instrument and tissue tracking. We demonstrate instrument displacement estimation, deformable surface reconstruction, and foundation-model fine-tuning. Extensive experiments and analysis demonstrate the effectiveness of our dataset and annotation framework for 3D surgical point tracking, reconstruction, and surgical action understanding. Homepage: https://wrld.github.io/surgtap-3d/

0.34

STEP: Surgical Point Tracking from Sparse Endpoints and Pseudo-trajectories

cs.CV ·2026-10-22 ·Bing Fan, Anwesa Choudhuri, Zhongpai Gao, Meng Zheng, Benjamin Planche +3 more
similarity 0.77
Abstract

Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obtain. We present STEP, a two-stage framework that learns from surgical video and sparse physical endpoints. First, a frozen offline teacher generates candidate trajectories, and temporal reversibility and stereo consistency select dense supervision for a causal student. Second, a robust physical endpoint loss anchors terminal correspondence, while a round-trip loss constrains temporal consistency. A gradient-free prefix exposes training to accumulated drift, while a final differentiable window bounds activation memory. The trained tracker processes a single RGB stream with fixed weights. In STIR-to-VL-SurgPT transfer, temporal-stereo union selection reduces endpoint error by 7.0% relative to unfiltered trajectories. On a post-hoc diagnostic of 29 VL-SurgPT clips excluded from the endpoint-training manifest, STEP reduces endpoint error from 31.52 to 16.80 pixels relative to dense-label fine-tuning. These results support combining curated trajectories with physical observations to train surgical point trackers.

0.17

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.77
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training

cs.RO cs.CV ·2026-10-04 ·Hanyang Hu, Zekai Liang, Florian Richter, Michael C. Yip
similarity 0.73
Abstract

Efficient and robust tracking of surgical robotic instruments is important for robot-assisted minimally invasive surgery, yet remains challenging due to the complexity of surgical scenes and the unconventional geometry of surgical instruments. Keypoint-based approaches are efficient, but their performance depends on reliable feature detection. Improving these detectors with real-world supervision is difficult because accurate real-world annotations are costly to obtain at scale. To address this limitation, we introduce a tracker-guided self-training framework that adapts a model pretrained on synthetic images to unlabeled real-world videos. Given measured robot joint states, an uncertainty-aware EKF recursively corrects the instrument pose and the observable joint angles by comparing projected model features with detected keypoints, shaft boundaries, and mask-derived cues. An RTS smoother subsequently refines the resulting trajectory, which is projected into pseudo-labels for fine-tuning the feature detector without laborious pose annotations. Experiments on real-world videos demonstrate consistent improvements from self-training across all evaluated keypoint metrics, and the resulting model outperforms prior approaches in both accuracy and runtime. The code and data will be released upon publication.

0.26

Beyond Instrument Motion: Recognizing Tissue Tension Toward Surgical Skill Assessment

cs.CV ·2026-08-18 ·Marko Haralović, Zhiqi Miao, Alexander Machiel Bont, Jiapan Guo, Frans van Workum +1 more
publishedbenchmark similarity 0.73
Abstract · The paper is accepted by ECCV 2026 Workshop On Medical Video Understanding

Surgical performance assessment in minimally invasive surgery largely relies on manual expert review, making it time-consuming, subjective, and difficult to scale. While existing surgical video understanding methods address tasks such as instrument segmentation, surgical phase recognition, and action recognition, they do not explicitly capture fine-grained tissue handling, a key indicator of surgical quality. To address this gap, we introduce tissue tension recognition, a new clinically motivated video understanding task for laparoscopic and robot-assisted rectal cancer surgery. To support this task, we construct SurgTension, the first expert-annotated tissue tension dataset, providing a benchmark for objective tissue tension recognition. We further propose TensionTRAC, a lightweight trajectory-based framework that models tissue tension from sparse point trajectories. Using a compact trajectory encoder, TensionTRAC achieves competitive performance against strong pretrained video backbones.

0.33

Colon3R: Cross-Domain 3D Reconstruction from Monocular Colonoscopic Video

cs.CV cs.RO ·2026-09-21 ·Zhihao Xing, Yingyu Wang, Liang Zhao, Shoudong Huang
code/data similarity 0.72
Abstract

Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not enough in-vivo labeled data available to adapt geometry foundation models to clinical colonoscopy. We present Colon3R, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations. Unlike source-only fine-tuning, which learns only from phantom and simulated data, Colon3R directly exploits unlabeled in-vivo video through teacher-derived cross-view supervision. Our proposed hierarchical quasi-rigid reliability selects reliable supervision at the sequence, directed-pair, and pixel levels, while source-preserving adaptation retains the learned coupled geometry during target-domain adaptation. Extensive experiments demonstrate that our method achieves superior overall performance over state-of-the-art approaches in depth, pointmap, and camera pose estimation. Qualitative comparisons on real in-vivo colonoscopy further show substantially more complete and geometrically consistent reconstructions than competing methods under clinical domain shift. The code is publicly available at https://github.com/vglx/Colon3R.

0.29

4D Triangle Splatting Reconstruction of Dynamic Endoscopic Scenes from Monocular Videos

cs.CV cs.RO ·2026-11-01 ·Laura Salort-Benejam, Stamatia Giannarou, Antonio Agudo
similarity 0.70
Abstract · Off-Grid; MICCAIW 2026

Robust 4D reconstruction of deformable endoscopic scenes from monocular videos remains challenging due to non-rigid tissue deformation, illumination changes, occlusions, and unknown camera trajectories. Reliable dynamic reconstruction of endoscopies could significantly enhance visualization, diagnostic accuracy and intraoperative guidance of minimally invasive procedures. We propose SurgicalTS, a self-supervised triangle-splatting framework for dynamic endoscopic scene reconstruction from static monocular cameras. The scene is represented by a canonical set of triangles jointly optimized with a deformation network. We introduce a quaternion-based deformation model, an improved color parametrization, spatio-temporal priors, and a redefined initialization strategy that improves completeness under occlusions. Extensive evaluation on challenging in-vivo endoscopy videos from diverse procedures shows that SurgicalTS successfully models soft-tissue deformations and tool-tissue interactions over time, while consistently outperforming state-of-the-art methods. Our method also reduces training times while maintaining competitive geometric and photometric accuracy results, highlighting the effectiveness of quaternion-based deformation modelling with physical consistency for robust and efficient 4D reconstruction of endoscopic scenes.

0.06

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.69
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70