CS Paper Radar

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation

Lixing Tan, Hongye Hao, Tianrun Gu, Qing Xia, Yuting Guo, Shuai Li, Aimin Hao

cs.CV ·submitted 2026-11-01 04:07 UTC · v2

Abstract

Registering intraoperative Ultrasound (US) bone-surface point clouds to preoperative Computed Tomography (CT) models can support radiation-free orthopedic navigation. Differences in imaging physics produce distinct surface sampling patterns, complicating cross-modal feature matching. Bone strongly reflects ultrasound and casts an acoustic shadow, so US captures only the probe-facing bone surface and leaves most CT points unmatched. This partial coverage makes correspondences ambiguous on near-symmetric bones. We propose CUFormer, a modality-aware registration framework. We introduce a Modality-Aware Transformer (MAT) that encodes input modality through identity embeddings and updates features through modality-specific adapters within a shared geometric matcher. We model imaging visibility and use predicted reference-side visibility to weight coarse and fine correspondences. CUFormer achieves the lowest mean registration errors among evaluated methods on two CT-US datasets, UltraBones100k and UltraBonesHip, and the CT-RGB-D dataset SpineDepth. On UltraBones100k, it reaches mean rotation error 4.53$^\circ$, translation error 3.19\,mm, and Root Mean Squared Error (RMSE) 2.54\,mm, reducing RMSE by 65.8\% relative to the best-performing baseline by this metric. These results demonstrate CUFormer's effectiveness in aligning partial bone surfaces with preoperative CT across anatomical sites.

Closest papers

Nearest neighbours by meaning across the whole index.

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.72
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.69
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue similarity 0.69
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.66
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data similarity 0.66
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

cs.CV physics.med-ph ·2026-10-25 ·Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz +4 more
code/data similarity 0.66
Abstract

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

0.24

Verifier-Guided Synthetic Augmentation for 3D Human Shape Generation

cs.CV stat.ML ·2026-10-02 ·Yuexuan Wu, Yang Xiang, Hamid Laga, Dip Das, Anuj Srivastava +1 more
similarity 0.64
Abstract

Limited training data diversity constrains generative modeling of 3D human bodies: conservative models remain close to observed examples, whereas exploratory models often violate basic body proportions. We introduce a verifier-guided augmentation framework that uses global and mode-local PCA to generate inexpensive candidates, screens them using correspondence-derived skeletal proportions and body-part geometry, and retrains a diffusion model on accepted candidates. Elastic registration provides both the modal structure used by distributed PCA and the dense anatomical correspondence needed for scalable screening without per-candidate body-model fitting. A blinded human study supports the verifier as a conservative gatekeeper, favoring verifier-accepted over rejected outputs. We evaluate full-pool verifier acceptance separately from the coverage and departure of accepted samples and combine them through EAUC. On 4,498 registered DFAUST surfaces, distributed-PCA augmentation achieves 86.32% acceptance, the highest CP-AUC (0.871), and the highest EAUC (0.752), improving EAUC by 32% over real-only and self-augmented diffusion. These results show that mode-local, verifier-guided proposals broaden diffusion generation while maintaining high agreement with calibrated body measurements.

0.17

Surface-to-Skeleton 3D Cephalometry: Estimating Hidden Skeletal Landmarks from CT-Derived External Soft-Tissue Surfaces

cs.CV ·2026-08-12 ·Tomoki Abe, Taiki Kanaya, Kazuki Saita, Mao Noda, Chie Tachiki +2 more
published similarity 0.63
Abstract · Accepted to AI4M3D Workshop at ECCV 2026

Existing 3D facial-landmark methods localize points on visible skin, but whether CT-defined internal skeletal landmarks can be inferred from external soft-tissue geometry remains unclear. We formulate a coordinate-consistent surface-to-skeleton task using same-acquisition CT-derived surfaces, separating estimation from optical-to-CT registration, scanner-domain, and acquisition-state effects, with coverage analyzed separately. From 240 clinical CT scans from two hospitals, we construct a locked retrospective protocol pairing CT-derived external soft-tissue point clouds with 21 skeletal landmarks and three visible soft-tissue landmarks. An integrated hierarchical point-cloud model achieves 2.97 mm mean radial error on skeletal landmarks and 3.03 mm on deep or surface-invisible landmarks in 40 held-out patients. Patient-mismatch controls support patient-specific signal beyond a fixed population configuration or global similarity alone, while coverage ablations indicate dependence on non-anterior geometry. Optical-transfer diagnostics reveal substantial coverage-related and global-configuration components, although deployable optical inference remains unresolved. These results answer the controlled feasibility question affirmatively and provide a basis for hidden skeletal landmark inference.

0.20