Surface-to-Skeleton 3D Cephalometry: Estimating Hidden Skeletal Landmarks from CT-Derived External Soft-Tissue Surfaces

Tomoki Abe, Taiki Kanaya, Kazuki Saita, Mao Noda, Chie Tachiki, Yasushi Nishii, Hideo Saito

cs.CV ·submitted 2026-08-12 19:09 UTC · v1
published

Abstract

Existing 3D facial-landmark methods localize points on visible skin, but whether CT-defined internal skeletal landmarks can be inferred from external soft-tissue geometry remains unclear. We formulate a coordinate-consistent surface-to-skeleton task using same-acquisition CT-derived surfaces, separating estimation from optical-to-CT registration, scanner-domain, and acquisition-state effects, with coverage analyzed separately. From 240 clinical CT scans from two hospitals, we construct a locked retrospective protocol pairing CT-derived external soft-tissue point clouds with 21 skeletal landmarks and three visible soft-tissue landmarks. An integrated hierarchical point-cloud model achieves 2.97 mm mean radial error on skeletal landmarks and 3.03 mm on deep or surface-invisible landmarks in 40 held-out patients. Patient-mismatch controls support patient-specific signal beyond a fixed population configuration or global similarity alone, while coverage ablations indicate dependence on non-anterior geometry. Optical-transfer diagnostics reveal substantial coverage-related and global-configuration components, although deployable optical inference remains unresolved. These results answer the controlled feasibility question affirmatively and provide a basis for hidden skeletal landmark inference.

Comment
Accepted to AI4M3D Workshop at ECCV 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Evaluating Transformation Models for pCLE Mosaic Registration

cs.CV ·2026-09-21 ·Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gonçalves, Alexander Hann +1 more
similarity 0.64
Abstract

Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can extend to provide anatomical context. Because of line-by-line acquisition, probe motion, and probe-tissue interaction, frame alignment generally requires a non-linear transformation whose accuracy is difficult to quantify: flexible transformation models can fit intensity features and noise, so appearance-based metrics such as Normalized Cross-Correlation (NCC) can improve without a genuine gain in geometric accuracy. We therefore establish a dataset of 132 frame pairs across fourteen pCLE sequences from 4 patients with manually annotated landmark correspondences, so that Target Registration Error (TRE) can serve as a geometrically grounded complement to NCC. We assess the effect of progressively increasing the transformation model's degrees of freedom, from translation to Thin Plate Spline (TPS), and of six feature-matching backends spanning classical (Shi-Tomasi, Lucas-Kanade) and learned (SuperPoint, SuperGlue, LightGlue, LoFTR, RoMa) approaches. Translation and rigid models prove insufficient under tissue deformation, while TPS with random sampling achieves the strongest landmark-derived alignment of the evaluated configurations; among the learned matchers, used without fine-tuning, only RoMa offers a robust, if modest, advantage over other methods. At the sequence level, pairwise registration quality proved an unreliable predictor of final mosaic quality, so mosaic quality must be evaluated directly rather than inferred from pairwise metrics.

0.34

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation

cs.CV ·2026-11-01 ·Lixing Tan, Hongye Hao, Tianrun Gu, Qing Xia, Yuting Guo +2 more
similarity 0.63
Abstract

Registering intraoperative Ultrasound (US) bone-surface point clouds to preoperative Computed Tomography (CT) models can support radiation-free orthopedic navigation. Differences in imaging physics produce distinct surface sampling patterns, complicating cross-modal feature matching. Bone strongly reflects ultrasound and casts an acoustic shadow, so US captures only the probe-facing bone surface and leaves most CT points unmatched. This partial coverage makes correspondences ambiguous on near-symmetric bones. We propose CUFormer, a modality-aware registration framework. We introduce a Modality-Aware Transformer (MAT) that encodes input modality through identity embeddings and updates features through modality-specific adapters within a shared geometric matcher. We model imaging visibility and use predicted reference-side visibility to weight coarse and fine correspondences. CUFormer achieves the lowest mean registration errors among evaluated methods on two CT-US datasets, UltraBones100k and UltraBonesHip, and the CT-RGB-D dataset SpineDepth. On UltraBones100k, it reaches mean rotation error 4.53$^\circ$, translation error 3.19\,mm, and Root Mean Squared Error (RMSE) 2.54\,mm, reducing RMSE by 65.8\% relative to the best-performing baseline by this metric. These results demonstrate CUFormer's effectiveness in aligning partial bone surfaces with preoperative CT across anatomical sites.

0.24

Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

cs.CV ·2026-10-06 ·Agnieszka Lach, Magdalena Wysocki, Feng Li, Mohammad Farid Azampour, Benjamin D. Killeen +5 more
published similarity 0.62
Abstract · 10 pages, 3 figures. Accepted at the 7th International Workshop on Advances in Simplifying Medical UltraSound (ASMUS 2026), held with MICCAI…

Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from the probe induces soft tissue deformations that inhibit accurate alignment. In this work, we introduce a deformable CT-ultrasound registration framework that incorporates anatomical priors derived from CT to improve registration under deformation. Rigid registration is first established using a robot-assisted optical tracking system, after which a deformable transformation is estimated using a sinusoidal implicit neural representation (SIREN) optimized per frame. Tissue stiffness is approximated from CT-based HU values and used as spatially varying regularization, suppressing deformation in rigid structures such as bone while allowing more flexibility in soft tissue. Two additional constraints capture the physics of probe contact: a contact-zone displacement prior that drives the displacement field to compress tissue below the probe face, and a fan-geometry regularization term based on beam direction and convex transducer field of view. Model parameters are optimized with a normalized gradient field (NGF). The proposed approach improves alignment over rigid initialisation by 17% and outperforms classical deformable baselines while maintaining near-zero topological folding.

0.52

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.61
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12

ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration

cs.RO ·2026-10-07 ·Tiancheng Li, Yingyu Wang, Peter Walker, Liang Zhao, Shoudong Huang
similarity 0.60
Abstract · Preprint

Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263.

0.25

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.60
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42

TRACE: Artifact-Robust Statistical Shape Modeling from Imperfect Surface Scans - A Case Study in Craniosynostosis 3D Photography

cs.CV cs.AI ·2026-08-22 ·Sanjay Bhandari, Nawazish Khan, Alzbeta Novotna, Tiffany Jeong, Loretta Bowman +5 more
published similarity 0.59
Abstract · Accepted at ShapeMI workshop at MICCAI 2026

Craniosynostosis severity analysis increasingly relies on statistical shape models (SSMs) to quantify cranial morphology, but most existing workflows depend on computed tomography or heavily curated three-dimensional (3D) photographs. Raw clinical 3D photographs provide a radiation-free and repeatable alternative, yet often contain shoulders, hands, hair, clothing, scanner noise, and incomplete boundaries that corrupt correspondences. We introduce the Template-constrained Robust Artifact-aware Correspondence Estimation (TRACE) framework, an unsupervised method for constructing SSMs directly from artifact-contaminated clinical 3D head photographs. TRACE predicts sparse anatomically corresponding head-surface control points from the raw point cloud, refines them through a coarse-to-fine Surface-Aware Deformation cascade, and uses thin-plate spline warping to deform a clean template mesh into a subject-specific head reconstruction. This template-constrained formulation keeps dense correspondences on clinically relevant head anatomy while suppressing non-head artifacts. The correspondence module is decoupled from the point-cloud encoder, enabling the same deformation pipeline to be paired with different backbones, including PointNet, DGCNN, and Point Transformer V3. Across all backbones, TRACE substantially improves surface sampling, topology preservation, and shape-model quality over prior SSM methods, providing a scalable foundation for photograph-based craniosynostosis shape analysis and a framework that may extend to other artifact-contaminated surface scans when an appropriate clean template is available.

0.42

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue similarity 0.59
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40