Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

Agnieszka Lach, Magdalena Wysocki, Feng Li, Mohammad Farid Azampour, Benjamin D. Killeen, Felix Ginzinger, Mathias Braun, Philipp Steininger, Heinz Deutschmann, Nassir Navab

cs.CV ·submitted 2026-10-06 14:22 UTC · v1
published

Abstract

Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from the probe induces soft tissue deformations that inhibit accurate alignment. In this work, we introduce a deformable CT-ultrasound registration framework that incorporates anatomical priors derived from CT to improve registration under deformation. Rigid registration is first established using a robot-assisted optical tracking system, after which a deformable transformation is estimated using a sinusoidal implicit neural representation (SIREN) optimized per frame. Tissue stiffness is approximated from CT-based HU values and used as spatially varying regularization, suppressing deformation in rigid structures such as bone while allowing more flexibility in soft tissue. Two additional constraints capture the physics of probe contact: a contact-zone displacement prior that drives the displacement field to compress tissue below the probe face, and a fan-geometry regularization term based on beam direction and convex transducer field of view. Model parameters are optimized with a normalized gradient field (NGF). The proposed approach improves alignment over rigid initialisation by 17% and outperforms classical deformable baselines while maintaining near-zero topological folding.

Comment
10 pages, 3 figures. Accepted at the 7th International Workshop on Advances in Simplifying Medical UltraSound (ASMUS 2026), held with MICCAI 2026; to appear in Springer LNCS 17276 (MICCAI 2026 Workshops and Challenges). Open-access camera-ready: https://papers.miccai.org/miccai-2026-sat/ASMUS_047.html

Closest papers

Nearest neighbours by meaning across the whole index.

Robotic Optical Coherence Tomography-Guided Geometric Modeling of Soft Tissue: 3D Representations for Data-Driven Closed-Loop Shape Control

cs.RO ·2026-10-23 ·Chaoyu Zhang, Guangshen Ma, Mark Draelos
similarity 0.65
Abstract · 30 pages, 18 figures

In medical robotics, data-driven soft-tissue shape control requires deforming tissue toward desired morphologies through sequential physical interactions. This challenge is particularly important in microscale manipulation, where localized deformation is difficult to observe, represent, and control, while physics-based models can be computationally expensive and difficult to adapt to realistic environments. Optical coherence tomography (OCT) provides high-resolution volumetric perception of tissue deformation, but target-conditioned control requires effective representations of both observed and desired tissue states. In this work, we introduce an OCT-guided data-driven framework for tissue shape control, learned from user-guided demonstrations and executed with closed-loop OCT feedback. We study full-volume, tissue-masked sparse-volume, and voxelized point-cloud representations, with or without residual conditioning, using deterministic (Explicit) and generative diffusion (Diffusion) policies. Across 12 configurations and 576 phantom rollouts on 3-DoF depth and 6-DoF directional tasks, OCT-derived 3D representations support both Explicit and Diffusion policies, with performance depending on representation and residual conditioning. Residual conditioning reduces directional Shape RMSE from 0.748 to 0.555 mm for full-volume Diffusion, while voxelized point-cloud Explicit with residuals achieves 0.534 mm for depth and 0.443 mm for directional control, with comparable accuracy at intermediate unseen targets and consistent performance across deployments. We further evaluate the framework in 60 ex vivo porcine rollouts, extending to biological tissue with final geometric errors comparable to human demonstrations. These results establish volumetric OCT as current and goal representations for learned closed-loop tissue shape control across deterministic and generative action models.

0.07

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data similarity 0.63
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50

Surface-to-Skeleton 3D Cephalometry: Estimating Hidden Skeletal Landmarks from CT-Derived External Soft-Tissue Surfaces

cs.CV ·2026-08-12 ·Tomoki Abe, Taiki Kanaya, Kazuki Saita, Mao Noda, Chie Tachiki +2 more
published similarity 0.62
Abstract · Accepted to AI4M3D Workshop at ECCV 2026

Existing 3D facial-landmark methods localize points on visible skin, but whether CT-defined internal skeletal landmarks can be inferred from external soft-tissue geometry remains unclear. We formulate a coordinate-consistent surface-to-skeleton task using same-acquisition CT-derived surfaces, separating estimation from optical-to-CT registration, scanner-domain, and acquisition-state effects, with coverage analyzed separately. From 240 clinical CT scans from two hospitals, we construct a locked retrospective protocol pairing CT-derived external soft-tissue point clouds with 21 skeletal landmarks and three visible soft-tissue landmarks. An integrated hierarchical point-cloud model achieves 2.97 mm mean radial error on skeletal landmarks and 3.03 mm on deep or surface-invisible landmarks in 40 held-out patients. Patient-mismatch controls support patient-specific signal beyond a fixed population configuration or global similarity alone, while coverage ablations indicate dependence on non-anterior geometry. Optical-transfer diagnostics reveal substantial coverage-related and global-configuration components, although deployable optical inference remains unresolved. These results answer the controlled feasibility question affirmatively and provide a basis for hidden skeletal landmark inference.

0.20

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

cs.RO ·2026-09-27 ·Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo +6 more
hot direction similarity 0.62
Abstract · Submitted to IEEE ICRA 2027

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

0.29

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

cs.CV ·2026-08-17 ·Hengjie Liu, Chushu Shen, Dan Ruan, Ke Sheng
code/data similarity 0.62
Abstract

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

0.44

DinoMUSE: A DINOv2-guided Framework for Unsupervised Lateral Motion Estimation in Ultrasound Elastography

eess.IV cs.CV ·2026-10-16 ·Xiyao Meng, Xingyue Wei, Baihua Luo, Bo Peng, Jianwen Luo
code/data similarity 0.60
Abstract

Quasi-static ultrasound elastography (USE) is a non-invasive imaging method for assessing soft tissue mechanical properties. Limited by low resolution, low sampling frequency and lack of phase information in the lateral direction, accurate lateral motion estimation remains a critical bottleneck in USE. Existing methods mainly rely on local image matching and physical constraints (such as tissue incompressibility assumption and effective Poisson's ratio), which lack sufficient contextual information. We present DinoMUSE, a DINO-guided mixture-of-experts (MoE) framework for unsupervised lateral motion estimation in USE. DinoMUSE incorporates high-level visual representations learned by DINOv2 into the motion estimation network to provide global contextual guidance. To facilitate effective interaction between DINOv2 features and local matching features, an MoE-based feature-fusion module adaptively transforms and integrates the two representations. Evaluations against NCC, GLUE, RAFT, and sPICTURE on simulation and in-vivo breast datasets show that DinoMUSE substantially improves lateral estimation accuracy while maintaining competitive axial performance. Specifically, DinoMUSE reduces the mean square error (MSE) of lateral displacement and strain estimation by 60% and 65%, respectively, compared with a SOTA algorithm on the simulation dataset. For in-vivo breast data, DinoMUSE achieves axial strain SNR and CNR of 5.70 and 4.82, and lateral strain SNR and CNR of 4.61 and 2.23, compared to 4.11 and 3.32, and 4.57 and 2.13 for the best competing method, alongside improved lesion visualization. These findings indicate the potential of leveraging transferable visual representations and adaptive feature fusion to improve lateral motion estimation in USE. The code is available at xxxxxxxx.

0.27

Recon2Servo: Robotic Ultrasound Visual Servoing via Learned Image-to-Motion Inference

cs.RO ·2026-10-05 ·Yameng Zhang, Pei Liu, Dianye Huang, Yizhao Qian, Zhongyu Chen +3 more
similarity 0.60
Abstract

Ultrasound visual servoing is essential for autonomous robotic ultrasound, yet 6-DoF probe control from 2D B-mode images remains challenging due to limited and ambiguous out-of-plane motion cues. Existing methods typically rely on anatomical priors or handcrafted visual features, limiting their generalizability across imaging targets. Inspired by trackerless 3D ultrasound reconstruction, we propose Recon2Servo, a visual servoing framework that learns image-to-motion inference directly from B-mode images for 6-DoF probe control. A DINOv3 encoder with low-rank adaptation and a bidirectional relation module estimate the relative probe pose between current and target images to guide iterative closed-loop target-view alignment. The framework combines supervised relative-pose learning, reconstruction-guided closed-loop adaptation, and bounded residual pose correction to improve motion inference during servoing. Evaluations on a public dataset and an in-house dataset collected from 12 healthy volunteers using different ultrasound systems demonstrate its effectiveness in reconstructed-volume servoing. Additional real-robot demonstrations of target-view alignment and dynamic tracking on a human forearm are provided in the supplementary video: https://youtu.be/qwsOdI-GMYk.

0.29

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound

cs.CV eess.IV ·2026-09-10 ·Weiying Chen, Yuchong Gao, Siyuan Li, Marek Reformat, Rui Zheng +1 more
top venue similarity 0.60
Abstract · Accepted to ECCV 2026. Camera-ready Author Version

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

0.40