CS Paper Radar

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo, Jiyul Lee, Jinseok Lee, Seonho Shim, Younghoon Noh, Youngbin Kong, Hyoun-Joong Kong

cs.RO ·submitted 2026-09-27 07:35 UTC · v1
hot direction

Abstract

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

Comment
Submitted to IEEE ICRA 2027

Closest papers

Nearest neighbours by meaning across the whole index.

From Freehand Demonstrations to Autonomous Robotic Ultrasound: An Anatomy-Anchored Learning Framework

cs.RO ·2026-10-23 ·Yuan Bi, Fangxu Han, Ye Su, Yiping Zhou, Zhongliang Jiang +1 more
similarity 0.74
Abstract

Ultrasound imaging is highly operator-dependent, motivating robotic systems that reproduce expert scanning skills consistently. These skills involve coordinated interpretation of anatomical landmarks, ultrasound images, and probe-tissue interactions that are difficult to encode in hand-designed control strategies. Imitation learning offers an alternative, but its observation and action representations should reflect the anatomically structured nature of scanning. We propose an anatomy-anchored imitation-learning framework that combines anatomy-guided probe placement with learned ultrasound navigation. The placement module identifies a task-specific anatomical starting point from external visual observations and establishes the initial probe pose as the reference frame for scanning. A flow-based policy then generates scanning motions from anchor-relative probe poses, ultrasound images, probe-mounted camera views, and contact forces, while a termination head predicts task completion. This avoids continuous reliance on third-person vision and reduces dependence on the robot-patient configuration. A handheld acquisition platform enables multimodal demonstrations to be collected during natural freehand scanning without a robot. On 16 unseen participants, task success reaches 96%, 94%, 88%, and 94% for kidney, gallbladder, and liver standard-plane acquisition and radial artery sweeping, respectively. Compared with a fine-tuned pi_0 model, success on the abdominal tasks improves by 10-42 percentage points, with lower time-to-target, peak contact force, and trajectory jerk. Ablations support the complementary roles of anatomical anchoring, egocentric vision, and force feedback. End-to-end trials with automatic placement achieve 90-100% success, and the policies transfer without retraining to a second robot with 83-100% success.

0.07

Contact-Aware Impedance Controller for Robot-Assisted Ultrasound Imaging

cs.RO ·2026-09-28 ·MD Miraj Arefin, M Efe Tiryaki
similarity 0.72
Abstract · 8 pages, 7 figures, submitted to the IEEE International Conference on Robotics and Automation (ICRA2027)

Safe robot-assisted ultrasound imaging requires a reliable controller able to detect and localize probe--tissue interaction. In this paper, we present a B-mode ultrasound image-based contact perception method and a contact-aware impedance controller for robotic ultrasound imaging. The proposed method detects acoustic contact independently of force measurements, enabling contact-conditioned force/torque taring to reduce residual wrench bias. During contact, the method continuously estimates the effective contact location along the curved probe surface and uses it to update the controller interaction frame, enabling visual servoing of the physical probe--tissue contact point during imaging. Experiments on an agar phantom demonstrated a contact-localization RMSE of $\mathbf{1.46 \pm 0.14}$~mm over probe roll angles from $\mathbf{-15^\circ}$ to $\mathbf{15^\circ}$. During static rolling, the proposed controller maintained task-space tracking accuracy comparable to a conventional fixed-frame impedance controller while reducing the maximum compressive interaction force from $\mathbf{31.56}$~N to $\mathbf{20.09}$~N, corresponding to a $\mathbf{36.3\%}$ reduction. These results demonstrate the potential of ultrasound images as direct contact feedback for safe and accurate robot-assisted ultrasound imaging.

0.18

Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning

cs.RO ·2026-08-30 ·Yizhao Qian, Jiayuan Luo, Wanyi Zhu, Yameng Zhang, Max Q. -H. Meng +2 more
similarity 0.71
Abstract

Robotic ultrasound policies operating directly on B-mode images require extensive interaction data, whereas real-robot data collection is costly and safety-constrained. Simulation provides a scalable alternative, but zero-shot transfer depends not only on single-frame realism but also on whether simulated observations reproduce task-relevant feature changes induced by probe motion. We term this cross-domain consistency task-relevant feature-dynamics fidelity (TR-FDF). Under local regularity assumptions, our contraction analysis shows that greater sensitivity of TR-FDF mismatch to probe motion reduces the effective closed-loop contraction margin, whereas motion-independent errors primarily enlarge the residual error bound. Guided by this analysis, we develop a TR-FDF-oriented ultrasound simulator that combines a shared structural intermediate domain, trajectory-level fixed noise, and few-step conditional flow generation. In phantom experiments, a policy trained exclusively in simulation succeeded in 390 of 400 zero-shot deployments across four target planes. The simulator achieved an FID of 29.66 and generated observations at 67.1 Hz. Controlled interventions, ablations, and baseline comparisons showed that TR-FDF sensitivity complements single-frame realism in predicting zero-shot transfer performance.

0.39

Dual-Rate Force-Image Control with Model-Based Orientation Limits for Robotic Ultrasound

cs.RO cs.CVeess.SY ·2026-10-05 ·Tyler Foster, Qiang Zhang, A B M Tahidul Haque, Anh Thu Nguyen
similarity 0.71
Abstract · 8 pages, 4 gigures, conference

Robotic ultrasound couples a high-rate contact-force loop with slower, delayed image feedback, so image-guided ultrasound probe rotation can perturb contact force before the resulting image response is observed. We derive a closed-form orientation-rate limit that bounds the modeled rotation-induced estimated-force excursion over a finite horizon while accounting for disturbance rejection by the fast force loop. The limit depends on local contact stiffness, force-loop gains, a conservative rotation-to-force gain bound, the excursion budget, and the prediction horizon. We implement this model in a dual-rate controller with timestamp-based delay reconstruction and joint-torque-based force estimation, and evaluate it on a curved gelatin phantom using paired controller comparisons and component ablations. Relative to unconstrained image guidance, the proposed rate-limited controller reduced first-second root-mean-square (RMS) estimated-force error by 0.40 N while increasing cue-convergence time by 0.94 s. A fixed rate cap near the analytically predicted ceiling produced no resolvable difference in force error and converged 0.32 s faster, indicating that the principal practical value of the model is the rate-design rule rather than online prediction. Delay reconstruction had no resolvable effect at the tested latency. A single-subject popliteal scan demonstrated feasibility, although the image cue was noise-limited on heterogeneous tissue.

0.13

Recon2Servo: Robotic Ultrasound Visual Servoing via Learned Image-to-Motion Inference

cs.RO ·2026-10-05 ·Yameng Zhang, Pei Liu, Dianye Huang, Yizhao Qian, Zhongyu Chen +3 more
similarity 0.69
Abstract

Ultrasound visual servoing is essential for autonomous robotic ultrasound, yet 6-DoF probe control from 2D B-mode images remains challenging due to limited and ambiguous out-of-plane motion cues. Existing methods typically rely on anatomical priors or handcrafted visual features, limiting their generalizability across imaging targets. Inspired by trackerless 3D ultrasound reconstruction, we propose Recon2Servo, a visual servoing framework that learns image-to-motion inference directly from B-mode images for 6-DoF probe control. A DINOv3 encoder with low-rank adaptation and a bidirectional relation module estimate the relative probe pose between current and target images to guide iterative closed-loop target-view alignment. The framework combines supervised relative-pose learning, reconstruction-guided closed-loop adaptation, and bounded residual pose correction to improve motion inference during servoing. Evaluations on a public dataset and an in-house dataset collected from 12 healthy volunteers using different ultrasound systems demonstrate its effectiveness in reconstructed-volume servoing. Additional real-robot demonstrations of target-view alignment and dynamic tracking on a human forearm are provided in the supplementary video: https://youtu.be/qwsOdI-GMYk.

0.29

From Self-Normal-Positioning to Omni-Directional Tracking: Real-Time Surface Modeling Enabled Probe Tilt Control for Robotic Ultrasound Imaging

cs.RO ·2026-08-11 ·Xihan Ma, Haichong Zhang
similarity 0.67
Abstract · 10 pages, 8 figures

Ultrasound (US) provides real-time, radiation-free imaging, but the image quality depends strongly on how the probe is oriented against the patient body. Robotic US can reduce operator workload and improve acquisition consistency; however, most existing systems focus on normal positioning, where the probe is maintained perpendicular to the local surface. This constraint is inadequate for examinations like echocardiography, where obtaining a diagnostic view requires a non-normal probe angle. Consequently, a clinically useful robotic system must sense the local surface in real-time and preserve the desired probe orientation. Here, we propose an omni-directional probe-orientation control framework that integrates RGB-D perception, local-surface modeling, and task-space orientation control. The surface model fuses multi-view point clouds and provides a quadratic estimate of the local surface. A desired imaging direction is then encoded relative to the normal, enabling the probe to track arbitrary angles. The framework was evaluated through flat-surface tracking, phantom target-angle recovery, and in-vivo tracking of an expert selected view. Results show that the mean angular tracking error was 1.06 +- 0.66 deg. The system recovered a non-normal tilt angle of up to 44.39 +- 2.59 deg relative to the surface normal, and acquired the desired heart chamber view in the phantom and in-vivo experiments.

0.10

ForceU-VLA: A Force-Aware Vision-Language-Action Model for Embodied Ultrasound Scanning

cs.RO cs.CV ·2026-08-15 ·Xingzheng Wu, Cheng Zhang, Guihao Yan, Xifeng Hu, Zhi Liu +1 more
top venuecode/data similarity 0.66
Abstract

Embodied intelligent ultrasound scanning enables the automation and standardization of the ultrasound examination process by integrating perception, decision-making, and execution capabilities. However, existing methods suffer from loosely coupled modeling between force and ultrasound modalities and lack awareness of scanning stages, which limits their ability to capture dynamic probe-tissue interactions. To address these issues, we propose ForceU-VLA, a force-aware Vision-Language-Action model for autonomous embodied ultrasound scanning, which leverages force signals and ultrasound image feedback throughout the scanning process to enable accurate and high-quality ultrasound acquisition. Firstly, we propose a Force-Ultrasound Synergistic Fusion Module (FUSFM) that synergistically fuses ultrasound visual and force-feedback information to provide stable, reliable guidance for probe motion. Secondly, a Stage-Adaptive Modulation Mechanism (SAMM) is proposed to accommodate the task requirements across different scanning stages by adaptively modulating multimodal features to enhance their representation quality. Additionally, we introduce ForceU-VLA-Data, a real-world, force-aware embodied ultrasound dataset that integrates visual, force, and action signals, including data from two organs across five representative clinical scanning views, and comprising 450 expert-collected trajectories with approximately 100,000 synchronized multimodal frames. Extensive experimental results demonstrate that ForceU-VLA significantly improves contact stability and probe pressure regulation in embodied ultrasound scanning, thereby effectively enhancing task execution quality and overall system reliability. The source code is available at https://github.com/VMVLab/ForceU-VLA.

0.54

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

cs.RO cs.CV ·2026-08-17 ·Cheng Zhang, Xingzheng Wu, Guihao Yan, Xifeng Hu, Zhi Liu +2 more
top venuedatasetcode/data similarity 0.64
Abstract

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.

0.51