Contact-Aware Impedance Controller for Robot-Assisted Ultrasound Imaging

MD Miraj Arefin, M Efe Tiryaki

cs.RO ·submitted 2026-09-28 06:14 UTC · v1

Abstract

Safe robot-assisted ultrasound imaging requires a reliable controller able to detect and localize probe--tissue interaction. In this paper, we present a B-mode ultrasound image-based contact perception method and a contact-aware impedance controller for robotic ultrasound imaging. The proposed method detects acoustic contact independently of force measurements, enabling contact-conditioned force/torque taring to reduce residual wrench bias. During contact, the method continuously estimates the effective contact location along the curved probe surface and uses it to update the controller interaction frame, enabling visual servoing of the physical probe--tissue contact point during imaging. Experiments on an agar phantom demonstrated a contact-localization RMSE of $\mathbf{1.46 \pm 0.14}$~mm over probe roll angles from $\mathbf{-15^\circ}$ to $\mathbf{15^\circ}$. During static rolling, the proposed controller maintained task-space tracking accuracy comparable to a conventional fixed-frame impedance controller while reducing the maximum compressive interaction force from $\mathbf{31.56}$~N to $\mathbf{20.09}$~N, corresponding to a $\mathbf{36.3\%}$ reduction. These results demonstrate the potential of ultrasound images as direct contact feedback for safe and accurate robot-assisted ultrasound imaging.

Comment
8 pages, 7 figures, submitted to the IEEE International Conference on Robotics and Automation (ICRA2027)

Closest papers

Nearest neighbours by meaning across the whole index.

Dual-Rate Force-Image Control with Model-Based Orientation Limits for Robotic Ultrasound

cs.RO cs.CVeess.SY ·2026-10-05 ·Tyler Foster, Qiang Zhang, A B M Tahidul Haque, Anh Thu Nguyen
similarity 0.78
Abstract · 8 pages, 4 gigures, conference

Robotic ultrasound couples a high-rate contact-force loop with slower, delayed image feedback, so image-guided ultrasound probe rotation can perturb contact force before the resulting image response is observed. We derive a closed-form orientation-rate limit that bounds the modeled rotation-induced estimated-force excursion over a finite horizon while accounting for disturbance rejection by the fast force loop. The limit depends on local contact stiffness, force-loop gains, a conservative rotation-to-force gain bound, the excursion budget, and the prediction horizon. We implement this model in a dual-rate controller with timestamp-based delay reconstruction and joint-torque-based force estimation, and evaluate it on a curved gelatin phantom using paired controller comparisons and component ablations. Relative to unconstrained image guidance, the proposed rate-limited controller reduced first-second root-mean-square (RMS) estimated-force error by 0.40 N while increasing cue-convergence time by 0.94 s. A fixed rate cap near the analytically predicted ceiling produced no resolvable difference in force error and converged 0.32 s faster, indicating that the principal practical value of the model is the rate-design rule rather than online prediction. Delay reconstruction had no resolvable effect at the tested latency. A single-subject popliteal scan demonstrated feasibility, although the image cue was noise-limited on heterogeneous tissue.

0.13

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

cs.RO ·2026-09-27 ·Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo +6 more
hot direction similarity 0.72
Abstract · Submitted to IEEE ICRA 2027

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

0.29

Task-Relevant Feature-Dynamics Fidelity Enables Zero-Shot Sim-to-Real Transfer for Robotic Ultrasound Scanning

cs.RO ·2026-08-30 ·Yizhao Qian, Jiayuan Luo, Wanyi Zhu, Yameng Zhang, Max Q. -H. Meng +2 more
similarity 0.62
Abstract

Robotic ultrasound policies operating directly on B-mode images require extensive interaction data, whereas real-robot data collection is costly and safety-constrained. Simulation provides a scalable alternative, but zero-shot transfer depends not only on single-frame realism but also on whether simulated observations reproduce task-relevant feature changes induced by probe motion. We term this cross-domain consistency task-relevant feature-dynamics fidelity (TR-FDF). Under local regularity assumptions, our contraction analysis shows that greater sensitivity of TR-FDF mismatch to probe motion reduces the effective closed-loop contraction margin, whereas motion-independent errors primarily enlarge the residual error bound. Guided by this analysis, we develop a TR-FDF-oriented ultrasound simulator that combines a shared structural intermediate domain, trajectory-level fixed noise, and few-step conditional flow generation. In phantom experiments, a policy trained exclusively in simulation succeeded in 390 of 400 zero-shot deployments across four target planes. The simulator achieved an FID of 29.66 and generated observations at 67.1 Hz. Controlled interventions, ablations, and baseline comparisons showed that TR-FDF sensitivity complements single-frame realism in predicting zero-shot transfer performance.

0.39

From Self-Normal-Positioning to Omni-Directional Tracking: Real-Time Surface Modeling Enabled Probe Tilt Control for Robotic Ultrasound Imaging

cs.RO ·2026-08-11 ·Xihan Ma, Haichong Zhang
similarity 0.61
Abstract · 10 pages, 8 figures

Ultrasound (US) provides real-time, radiation-free imaging, but the image quality depends strongly on how the probe is oriented against the patient body. Robotic US can reduce operator workload and improve acquisition consistency; however, most existing systems focus on normal positioning, where the probe is maintained perpendicular to the local surface. This constraint is inadequate for examinations like echocardiography, where obtaining a diagnostic view requires a non-normal probe angle. Consequently, a clinically useful robotic system must sense the local surface in real-time and preserve the desired probe orientation. Here, we propose an omni-directional probe-orientation control framework that integrates RGB-D perception, local-surface modeling, and task-space orientation control. The surface model fuses multi-view point clouds and provides a quadratic estimate of the local surface. A desired imaging direction is then encoded relative to the normal, enabling the probe to track arbitrary angles. The framework was evaluated through flat-surface tracking, phantom target-angle recovery, and in-vivo tracking of an expert selected view. Results show that the mean angular tracking error was 1.06 +- 0.66 deg. The system recovered a non-normal tilt angle of up to 44.39 +- 2.59 deg relative to the surface normal, and acquired the desired heart chamber view in the phantom and in-vivo experiments.

0.10

CoPRE: Improving Sensitivity in Proprioceptive Contact Detection for Low-Cost Robot Arms

cs.RO ·2026-09-23 ·Yuxiao Zhu, Jinzhou Li, Yifei Dong, Muhammad Suhail, Chunyuan Yang +4 more
similarity 0.61
Abstract

Contact detection during robotic manipulation allows robots to recognize unexpected contact and adapt their motion accordingly. However, in low-cost robot arms without dedicated force or tactile sensors, detecting weak contacts from proprioception is challenging because the resulting changes in joint-level proprioceptive signals can be small compared to normal variation and noise caused by robot motion itself. We introduce Contact-free Proprioceptive Response Estimation (CoPRE), improving proprioceptive contact detection sensitivity using only contact-free motion, without additional force sensors, contact labels, or analytical dynamics models. CoPRE estimate the expected joint torques under contact-free motion from proprioceptive state history and commanded motion, while removing recent observations that may already reflect contact. It then computes the residual between the expected and observed joint torque estimates, and maps this residual to a contact score using a noise-weighted Jacobian. Real-robot experiments on ARX Arm and Unitree G1 show that CoPRE achieves 74.1% and 82.2% recall on the tested contact trials, compared with 0%/0% on ARX and 16.3%/42.2% on G1 for the learned torque-prediction and inverse-dynamics baselines. CoPRE also reaches 90% detection rate for pushing force at 3.5 N on ARX and 5.5 N on G1. To demonstrate the downstream utility of our method, we implement belief-space manipulation planning for obstacle-aware object placement and book insertion where detected contacts update the spatial belief and enable the robot to retreat from blocked motions, adjust its pose, and retry. Project website at https://copre-arm.github.io

0.35

ForceU-VLA: A Force-Aware Vision-Language-Action Model for Embodied Ultrasound Scanning

cs.RO cs.CV ·2026-08-15 ·Xingzheng Wu, Cheng Zhang, Guihao Yan, Xifeng Hu, Zhi Liu +1 more
top venuecode/data similarity 0.59
Abstract

Embodied intelligent ultrasound scanning enables the automation and standardization of the ultrasound examination process by integrating perception, decision-making, and execution capabilities. However, existing methods suffer from loosely coupled modeling between force and ultrasound modalities and lack awareness of scanning stages, which limits their ability to capture dynamic probe-tissue interactions. To address these issues, we propose ForceU-VLA, a force-aware Vision-Language-Action model for autonomous embodied ultrasound scanning, which leverages force signals and ultrasound image feedback throughout the scanning process to enable accurate and high-quality ultrasound acquisition. Firstly, we propose a Force-Ultrasound Synergistic Fusion Module (FUSFM) that synergistically fuses ultrasound visual and force-feedback information to provide stable, reliable guidance for probe motion. Secondly, a Stage-Adaptive Modulation Mechanism (SAMM) is proposed to accommodate the task requirements across different scanning stages by adaptively modulating multimodal features to enhance their representation quality. Additionally, we introduce ForceU-VLA-Data, a real-world, force-aware embodied ultrasound dataset that integrates visual, force, and action signals, including data from two organs across five representative clinical scanning views, and comprising 450 expert-collected trajectories with approximately 100,000 synchronized multimodal frames. Extensive experimental results demonstrate that ForceU-VLA significantly improves contact stability and probe pressure regulation in embodied ultrasound scanning, thereby effectively enhancing task execution quality and overall system reliability. The source code is available at https://github.com/VMVLab/ForceU-VLA.

0.54

Imp-ACT: Adaptive Impedance Control and Action Chunking with Transformers to Learn Contact-Rich Manipulation from Demonstrations

cs.RO ·2026-09-25 ·Luca Zanetti, Doganay Sirintuna, Idil Ozdamar, Pietro Balatti, Heng Zhang +1 more
similarity 0.58
Abstract · 9 pages, 5 figures, submitted to IEEE International Conference on Robotics & Automation 2027, for associated video see https://youtu.be/iAu_…

Contact-rich manipulation requires robots to balance accurate motion tracking with compliant interaction, yet most visual-action policies leave compliance fixed at the controller level. We present Imp-ACT, a methodologically grounded and practical approach to incorporating direction-dependent Cartesian stiffness modulation directly into demonstration collection, without manual stiffness selection or offline target reconstruction. During teleoperation, a self-tuning impedance controller adapts stiffness along the instantaneous direction of motion while maintaining compliance in orthogonal directions. The adapted stiffness is applied and recorded alongside visual observations and motion commands, capturing motion and compliance under the same dynamics. We implement this pipeline using Action Chunking with Transformer (ACT) to predict end-effector pose, gripper action, and motion-direction stiffness from visual, proprioceptive, and wrench observations. The performance of Imp-ACT is evaluated on wiping and plug insertion using both success rate and quantitative measures of contact behavior. Compared with fixed low- and high-stiffness baselines, Imp-ACT achieves comparable or higher success while maintaining low interaction forces. In wiping, it reduces contact-force vibration by approximately $29\times$ relative to the compliant baseline and $180\times$ relative to the stiff baseline. In plug insertion, it reduces forces orthogonal to the insertion direction by $43\%$ relative to the better fixed-stiffness baseline. These results highlight the benefit of maintaining sufficient stiffness along the direction needed for task execution while preserving compliance in other directions to limit contact forces and accommodate environmental constraints.

0.32

Learning Reflexive Behavior for Contact-Rich Manipulation

cs.RO ·2026-10-02 ·Quan Nguyen, Yunho Kim, Joonho Lee
similarity 0.57
Abstract

During contact-rich manipulation, interactions between a robot and its environment carry information about local geometry: a surface prevents penetration, a bore guides a peg. A controller that exploits these interactions can comply with environmental constraints while preserving task intent. Robot-earning systems commonly use position, hybrid force-position, or Cartesian impedance control. Their prescribed tracking objectives, stiffness, or force-control directions may not match local constraints and may degrade performance. We learn a proprioceptive reflex policy in simulation on three simple interaction primitives: a spring, a plane, and a rail. The policy maps task-space commands to joint-position targets using state history, without direct force or geometrical measurements. Once trained, it serves as a frozen execution layer beneath higher-level controllers. We evaluate it in dual-arm box lifting, peg insertion, and surface following. In box lifting, the reflex kept the force below the threshold while the baseline failed. In rough-surface following it stayed below the 10 N reference, on par with tuned hybrid force-position control. In 0.02 mm peg insertion It reduced mean estimated contact force to less than half that of the baseline while increasing hardware success rates from at most 22 % to 36-58 %. By separating contact response from command generation, the reflex policy provides motion planners, learned policies, and teleoperators with robust contact-rich execution.

0.15