From Self-Normal-Positioning to Omni-Directional Tracking: Real-Time Surface Modeling Enabled Probe Tilt Control for Robotic Ultrasound Imaging

Xihan Ma, Haichong Zhang

cs.RO ·submitted 2026-08-11 20:16 UTC · v1

Abstract

Ultrasound (US) provides real-time, radiation-free imaging, but the image quality depends strongly on how the probe is oriented against the patient body. Robotic US can reduce operator workload and improve acquisition consistency; however, most existing systems focus on normal positioning, where the probe is maintained perpendicular to the local surface. This constraint is inadequate for examinations like echocardiography, where obtaining a diagnostic view requires a non-normal probe angle. Consequently, a clinically useful robotic system must sense the local surface in real-time and preserve the desired probe orientation. Here, we propose an omni-directional probe-orientation control framework that integrates RGB-D perception, local-surface modeling, and task-space orientation control. The surface model fuses multi-view point clouds and provides a quadratic estimate of the local surface. A desired imaging direction is then encoded relative to the normal, enabling the probe to track arbitrary angles. The framework was evaluated through flat-surface tracking, phantom target-angle recovery, and in-vivo tracking of an expert selected view. Results show that the mean angular tracking error was 1.06 +- 0.66 deg. The system recovered a non-normal tilt angle of up to 44.39 +- 2.59 deg relative to the surface normal, and acquired the desired heart chamber view in the phantom and in-vivo experiments.

Comment
10 pages, 8 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

cs.RO ·2026-09-27 ·Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo +6 more
hot direction similarity 0.67
Abstract · Submitted to IEEE ICRA 2027

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

0.29

Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization

cs.RO eess.IV ·2026-09-18 ·Kyoungmo Koo, Guangshen Ma, Xueding Wang, Mark Draelos
similarity 0.66
Abstract · 9 pages, 7 figures, 3 tables

Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of $1.75\pm0.51$ mm and $0.85\pm0.11$ mm, respectively, compared with $1.72\pm0.51$ mm and $0.84\pm0.12$ mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE$\pm$SD values of $0.41\pm0.35$ mm for the cone and $0.50\pm0.41$ mm for the triangular prism, closely matching the three-marker results of $0.40\pm0.35$ mm and $0.48\pm0.40$ mm, respectively.

0.21

Contact-Aware Impedance Controller for Robot-Assisted Ultrasound Imaging

cs.RO ·2026-09-28 ·MD Miraj Arefin, M Efe Tiryaki
similarity 0.61
Abstract · 8 pages, 7 figures, submitted to the IEEE International Conference on Robotics and Automation (ICRA2027)

Safe robot-assisted ultrasound imaging requires a reliable controller able to detect and localize probe--tissue interaction. In this paper, we present a B-mode ultrasound image-based contact perception method and a contact-aware impedance controller for robotic ultrasound imaging. The proposed method detects acoustic contact independently of force measurements, enabling contact-conditioned force/torque taring to reduce residual wrench bias. During contact, the method continuously estimates the effective contact location along the curved probe surface and uses it to update the controller interaction frame, enabling visual servoing of the physical probe--tissue contact point during imaging. Experiments on an agar phantom demonstrated a contact-localization RMSE of $\mathbf{1.46 \pm 0.14}$~mm over probe roll angles from $\mathbf{-15^\circ}$ to $\mathbf{15^\circ}$. During static rolling, the proposed controller maintained task-space tracking accuracy comparable to a conventional fixed-frame impedance controller while reducing the maximum compressive interaction force from $\mathbf{31.56}$~N to $\mathbf{20.09}$~N, corresponding to a $\mathbf{36.3\%}$ reduction. These results demonstrate the potential of ultrasound images as direct contact feedback for safe and accurate robot-assisted ultrasound imaging.

0.18

Dual-Rate Force-Image Control with Model-Based Orientation Limits for Robotic Ultrasound

cs.RO cs.CVeess.SY ·2026-10-05 ·Tyler Foster, Qiang Zhang, A B M Tahidul Haque, Anh Thu Nguyen
similarity 0.60
Abstract · 8 pages, 4 gigures, conference

Robotic ultrasound couples a high-rate contact-force loop with slower, delayed image feedback, so image-guided ultrasound probe rotation can perturb contact force before the resulting image response is observed. We derive a closed-form orientation-rate limit that bounds the modeled rotation-induced estimated-force excursion over a finite horizon while accounting for disturbance rejection by the fast force loop. The limit depends on local contact stiffness, force-loop gains, a conservative rotation-to-force gain bound, the excursion budget, and the prediction horizon. We implement this model in a dual-rate controller with timestamp-based delay reconstruction and joint-torque-based force estimation, and evaluate it on a curved gelatin phantom using paired controller comparisons and component ablations. Relative to unconstrained image guidance, the proposed rate-limited controller reduced first-second root-mean-square (RMS) estimated-force error by 0.40 N while increasing cue-convergence time by 0.94 s. A fixed rate cap near the analytically predicted ceiling produced no resolvable difference in force error and converged 0.32 s faster, indicating that the principal practical value of the model is the rate-design rule rather than online prediction. Delay reconstruction had no resolvable effect at the tested latency. A single-subject popliteal scan demonstrated feasibility, although the image cue was noise-limited on heterogeneous tissue.

0.13

From Freehand Demonstrations to Autonomous Robotic Ultrasound: An Anatomy-Anchored Learning Framework

cs.RO ·2026-10-23 ·Yuan Bi, Fangxu Han, Ye Su, Yiping Zhou, Zhongliang Jiang +1 more
similarity 0.60
Abstract

Ultrasound imaging is highly operator-dependent, motivating robotic systems that reproduce expert scanning skills consistently. These skills involve coordinated interpretation of anatomical landmarks, ultrasound images, and probe-tissue interactions that are difficult to encode in hand-designed control strategies. Imitation learning offers an alternative, but its observation and action representations should reflect the anatomically structured nature of scanning. We propose an anatomy-anchored imitation-learning framework that combines anatomy-guided probe placement with learned ultrasound navigation. The placement module identifies a task-specific anatomical starting point from external visual observations and establishes the initial probe pose as the reference frame for scanning. A flow-based policy then generates scanning motions from anchor-relative probe poses, ultrasound images, probe-mounted camera views, and contact forces, while a termination head predicts task completion. This avoids continuous reliance on third-person vision and reduces dependence on the robot-patient configuration. A handheld acquisition platform enables multimodal demonstrations to be collected during natural freehand scanning without a robot. On 16 unseen participants, task success reaches 96%, 94%, 88%, and 94% for kidney, gallbladder, and liver standard-plane acquisition and radial artery sweeping, respectively. Compared with a fine-tuned pi_0 model, success on the abdominal tasks improves by 10-42 percentage points, with lower time-to-target, peak contact force, and trajectory jerk. Ablations support the complementary roles of anatomical anchoring, egocentric vision, and force feedback. End-to-end trials with automatic placement achieve 90-100% success, and the policies transfer without retraining to a second robot with 83-100% success.

0.07

Recon2Servo: Robotic Ultrasound Visual Servoing via Learned Image-to-Motion Inference

cs.RO ·2026-10-05 ·Yameng Zhang, Pei Liu, Dianye Huang, Yizhao Qian, Zhongyu Chen +3 more
similarity 0.59
Abstract

Ultrasound visual servoing is essential for autonomous robotic ultrasound, yet 6-DoF probe control from 2D B-mode images remains challenging due to limited and ambiguous out-of-plane motion cues. Existing methods typically rely on anatomical priors or handcrafted visual features, limiting their generalizability across imaging targets. Inspired by trackerless 3D ultrasound reconstruction, we propose Recon2Servo, a visual servoing framework that learns image-to-motion inference directly from B-mode images for 6-DoF probe control. A DINOv3 encoder with low-rank adaptation and a bidirectional relation module estimate the relative probe pose between current and target images to guide iterative closed-loop target-view alignment. The framework combines supervised relative-pose learning, reconstruction-guided closed-loop adaptation, and bounded residual pose correction to improve motion inference during servoing. Evaluations on a public dataset and an in-house dataset collected from 12 healthy volunteers using different ultrasound systems demonstrate its effectiveness in reconstructed-volume servoing. Additional real-robot demonstrations of target-view alignment and dynamic tracking on a human forearm are provided in the supplementary video: https://youtu.be/qwsOdI-GMYk.

0.29

Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery

cs.RO ·2026-11-02 ·Yuxin Chen, Wenxuan Wang, Wanwen Chen, Qi Zeng, Septimiu E. Salcudean
similarity 0.59
Abstract

Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

0.28

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

cs.RO ·2026-08-31 ·Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan
similarity 0.57
Abstract · 34 pages, 9374 words

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

0.31