Recon2Servo: Robotic Ultrasound Visual Servoing via Learned Image-to-Motion Inference

Yameng Zhang, Pei Liu, Dianye Huang, Yizhao Qian, Zhongyu Chen, Xiangyu Chu, K. W. Samuel Au, Zhongliang Jiang

cs.RO ·submitted 2026-10-05 09:07 UTC · v1

Abstract

Ultrasound visual servoing is essential for autonomous robotic ultrasound, yet 6-DoF probe control from 2D B-mode images remains challenging due to limited and ambiguous out-of-plane motion cues. Existing methods typically rely on anatomical priors or handcrafted visual features, limiting their generalizability across imaging targets. Inspired by trackerless 3D ultrasound reconstruction, we propose Recon2Servo, a visual servoing framework that learns image-to-motion inference directly from B-mode images for 6-DoF probe control. A DINOv3 encoder with low-rank adaptation and a bidirectional relation module estimate the relative probe pose between current and target images to guide iterative closed-loop target-view alignment. The framework combines supervised relative-pose learning, reconstruction-guided closed-loop adaptation, and bounded residual pose correction to improve motion inference during servoing. Evaluations on a public dataset and an in-house dataset collected from 12 healthy volunteers using different ultrasound systems demonstrate its effectiveness in reconstructed-volume servoing. Additional real-robot demonstrations of target-view alignment and dynamic tracking on a human forearm are provided in the supplementary video: https://youtu.be/qwsOdI-GMYk.

Closest papers

Nearest neighbours by meaning across the whole index.

SonoWorld: Towards Interactive Pose-Controllable Ultrasound World Models

cs.CV ·2026-10-14 ·Zefan Yang, Zheyuan Zhang, Boris Maihe, Yikang Liu, Hang Yu +5 more
similarity 0.71
Abstract

Robotic ultrasound can standardize image acquisition and reduce operator workload and variability, but policy learning remains limited by the lack of realistic, controllable simulation environments. While controllable world models have advanced rapidly in natural-image domains, ultrasound world modeling remains challenging because each frame captures only a cross-section of unobserved 3D anatomy, causing small probe motions to induce large appearance changes. Existing approaches rely on robot-tracked poses and latent-space prediction, but do not directly generate the observations required for interactive control. We propose SonoWorld, a causal ultrasound world model that learns video dynamics from unlabeled clinical videos and grounds them to 6-DoF control using a small set of freehand clinical scans tracked with an EM sensor. SonoWorld is trained in three stages: pretraining a latent-action-conditioned video diffusion model on around 6.9 million unlabeled multi-organ ultrasound frames; grounding the learned video dynamics to metric probe poses with a small EM-tracked thyroid dataset; and applying distribution matching distillation to enable causal, long-horizon autoregressive generation with selectively caching eviction tokens at inference time. We evaluate controllability through pose-following fidelity, round-trip consistency, and axis-specific control under synthetic actions on held-out tracked scans, and further validate it with a user study. In model-based action discrimination, SonoWorld correctly ranks the target-directed probe motion over an equal-magnitude opposite motion in up to 74.8% of trials. To our knowledge, SonoWorld is the first causal, pose-controllable ultrasound world model learned primarily from freehand clinical videos, providing a data-driven interactive environment for robotic ultrasound data acquisition and policy evaluation.

0.08

Contact-Adaptive Robotic Ultrasound Probe Control for Tissue Exploration and Continuous Task-Relevant Visualization Using Robot-Free Image-Motion Demonstration

cs.RO ·2026-09-27 ·Seong Jeong, Minsung Kim, Dongho Yee, Juahn Oh, Yechan Seo +6 more
hot direction similarity 0.69
Abstract · Submitted to IEEE ICRA 2027

Robotic ultrasound commonly targets standardized views, predefined scanning protocols, or expert-scan reproduction. We target a different role: while a clinician performs the primary procedure, a robotic assistant maintains a clinician-selected view so that changing tissue remains observable. We present contact-adaptive robotic ultrasound monitoring derived from robot-free demonstrations. Sonologger clamps a six-axis inertial sensor to the clinician-operated probe and records synchronized ultrasound and probe-frame relative rotations without a robot, camera, or tracker. Rather than imitating trajectories, the recordings measure which probe axis and sign the clinician uses to correct an image offset. A measured image latency is removed before still-move-still segmentation yields relative-rotation labels; translation is excluded from control because of inertial drift. These measurements parameterize the Demonstration-Informed Image-Motion Controller (DIMC), an interpretable, non-learned controller combined with beam-axis force regulation and an independent safety supervisor with 5 N forced retreat. On a dynamic bladder phantom, DIMC acquired and held a task-relevant view in 7 of 7 blind, pose-paired trials versus 1 of 7 for a static hold (McNemar p = 0.031), and retained the view during syringe-driven hydro-distension while the supervisor bounded the force excursion. The framework offers an operational representation of ultrasound context for contact-adaptive intraoperative monitoring; clinical validation remains future work.

0.29

From Freehand Demonstrations to Autonomous Robotic Ultrasound: An Anatomy-Anchored Learning Framework

cs.RO ·2026-10-23 ·Yuan Bi, Fangxu Han, Ye Su, Yiping Zhou, Zhongliang Jiang +1 more
similarity 0.68
Abstract

Ultrasound imaging is highly operator-dependent, motivating robotic systems that reproduce expert scanning skills consistently. These skills involve coordinated interpretation of anatomical landmarks, ultrasound images, and probe-tissue interactions that are difficult to encode in hand-designed control strategies. Imitation learning offers an alternative, but its observation and action representations should reflect the anatomically structured nature of scanning. We propose an anatomy-anchored imitation-learning framework that combines anatomy-guided probe placement with learned ultrasound navigation. The placement module identifies a task-specific anatomical starting point from external visual observations and establishes the initial probe pose as the reference frame for scanning. A flow-based policy then generates scanning motions from anchor-relative probe poses, ultrasound images, probe-mounted camera views, and contact forces, while a termination head predicts task completion. This avoids continuous reliance on third-person vision and reduces dependence on the robot-patient configuration. A handheld acquisition platform enables multimodal demonstrations to be collected during natural freehand scanning without a robot. On 16 unseen participants, task success reaches 96%, 94%, 88%, and 94% for kidney, gallbladder, and liver standard-plane acquisition and radial artery sweeping, respectively. Compared with a fine-tuned pi_0 model, success on the abdominal tasks improves by 10-42 percentage points, with lower time-to-target, peak contact force, and trajectory jerk. Ablations support the complementary roles of anatomical anchoring, egocentric vision, and force feedback. End-to-end trials with automatic placement achieve 90-100% success, and the policies transfer without retraining to a second robot with 83-100% success.

0.07

DinoMUSE: A DINOv2-guided Framework for Unsupervised Lateral Motion Estimation in Ultrasound Elastography

eess.IV cs.CV ·2026-10-16 ·Xiyao Meng, Xingyue Wei, Baihua Luo, Bo Peng, Jianwen Luo
code/data similarity 0.67
Abstract

Quasi-static ultrasound elastography (USE) is a non-invasive imaging method for assessing soft tissue mechanical properties. Limited by low resolution, low sampling frequency and lack of phase information in the lateral direction, accurate lateral motion estimation remains a critical bottleneck in USE. Existing methods mainly rely on local image matching and physical constraints (such as tissue incompressibility assumption and effective Poisson's ratio), which lack sufficient contextual information. We present DinoMUSE, a DINO-guided mixture-of-experts (MoE) framework for unsupervised lateral motion estimation in USE. DinoMUSE incorporates high-level visual representations learned by DINOv2 into the motion estimation network to provide global contextual guidance. To facilitate effective interaction between DINOv2 features and local matching features, an MoE-based feature-fusion module adaptively transforms and integrates the two representations. Evaluations against NCC, GLUE, RAFT, and sPICTURE on simulation and in-vivo breast datasets show that DinoMUSE substantially improves lateral estimation accuracy while maintaining competitive axial performance. Specifically, DinoMUSE reduces the mean square error (MSE) of lateral displacement and strain estimation by 60% and 65%, respectively, compared with a SOTA algorithm on the simulation dataset. For in-vivo breast data, DinoMUSE achieves axial strain SNR and CNR of 5.70 and 4.82, and lateral strain SNR and CNR of 4.61 and 2.23, compared to 4.11 and 3.32, and 4.57 and 2.13 for the best competing method, alongside improved lesion visualization. These findings indicate the potential of leveraging transferable visual representations and adaptive feature fusion to improve lateral motion estimation in USE. The code is available at xxxxxxxx.

0.27

Scanning While Imagining: A Scene-Graph World Model for Robotic Ultrasound Navigation

cs.RO cs.AI ·2026-09-26 ·Xuesong Li, Shuai Chen, Feng Li, Zhongliang Jiang, Nassir Navab +1 more
code/data similarity 0.67
Abstract

Ultrasound (US) acquisition depends on the operator's ability to interpret anatomy and anticipate how the view will change with probe motion. Many robotic US navigation methods select actions without explicitly predicting these anatomical changes. We propose SonoGraph-WM, an action- and goal-conditioned world model for anticipatory probe navigation. The model represents anatomy as scene graphs (SGs), capturing visible structures, their geometry, and spatial relationships without synthesizing US images. Given a history of SGs and probe poses, a unified Transformer jointly predicts future SGs and poses. A receding-horizon planner recursively imagines candidate trajectories, selects the shortest predicted path reaching a goal graph, and follows it over a short execution horizon before replanning from new observations. To reduce reliance on tracked and anatomically annotated US sequences, we generate aligned SG--pose training data from computed tomography (CT) label maps along surface-constrained probe trajectories. On four held-out CT cases, spatial relation F1 remains above 93% over 20 prediction steps, and closed-loop navigation achieves 77.50% and 75.00% success for the gallbladder and pancreas, respectively, using annotation-derived SGs. In robot--phantom navigation experiments with label-map-derived SGs, the planner reached the target view in 73.7% of trials. These findings support CT-supervised anatomical world modeling for probe planning and highlight the importance of frequent observation updates for reliable navigation. Project Page: https://noseefood.github.io/us-sonograph-wm/

0.35

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

cs.CV cs.RO ·2026-10-07 ·Keke Yang, Erqi Wang, Sainan Guan, Hongliang Ren
code/data similarity 0.66
Abstract

World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29\% and 38\%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.

0.30

Surgical Kinematics from Monocular Video with Learned Articulated Motion Constraints

cs.CV cs.RO ·2026-09-23 ·Mehmet Kerem Turkcan, Soham Samal, Zoran Kostic
benchmark similarity 0.66
Abstract

Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder and temporal convolutional heads integrate this representation with mask geometry, monocular depth and visual state estimates from arm-specific multilayer regression networks. Our position branch predicts displacement magnitude and direction separately to preserve traveled distance. We fit trajectories to predicted state observations and motion increments by differentiable weighted least squares, expressing quaternion observations relative to cumulative predicted rotations to obtain a quadratic orientation objective. We evaluate reconstruction across 2,802 Open-H episodes. Compared with LiveMAE on the main Open-H benchmark, our method reduces path-length mean absolute error from 0.45 to 0.34\,cm and increases temporal mean average precision for motion segmentation from 44.54\% to 54.44\%.

0.20

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data similarity 0.66
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50