CS Paper Radar

SonoWorld: Towards Interactive Pose-Controllable Ultrasound World Models

Zefan Yang, Zheyuan Zhang, Boris Maihe, Yikang Liu, Hang Yu, Ankush Mukherjee, Xiao Chen, Pingkun Yan, Terrence Chen, Shanhui Sun

cs.CV ·submitted 2026-10-14 00:07 UTC · v2

Abstract

Robotic ultrasound can standardize image acquisition and reduce operator workload and variability, but policy learning remains limited by the lack of realistic, controllable simulation environments. While controllable world models have advanced rapidly in natural-image domains, ultrasound world modeling remains challenging because each frame captures only a cross-section of unobserved 3D anatomy, causing small probe motions to induce large appearance changes. Existing approaches rely on robot-tracked poses and latent-space prediction, but do not directly generate the observations required for interactive control. We propose SonoWorld, a causal ultrasound world model that learns video dynamics from unlabeled clinical videos and grounds them to 6-DoF control using a small set of freehand clinical scans tracked with an EM sensor. SonoWorld is trained in three stages: pretraining a latent-action-conditioned video diffusion model on around 6.9 million unlabeled multi-organ ultrasound frames; grounding the learned video dynamics to metric probe poses with a small EM-tracked thyroid dataset; and applying distribution matching distillation to enable causal, long-horizon autoregressive generation with selectively caching eviction tokens at inference time. We evaluate controllability through pose-following fidelity, round-trip consistency, and axis-specific control under synthetic actions on held-out tracked scans, and further validate it with a user study. In model-based action discrimination, SonoWorld correctly ranks the target-directed probe motion over an equal-magnitude opposite motion in up to 74.8% of trials. To our knowledge, SonoWorld is the first causal, pose-controllable ultrasound world model learned primarily from freehand clinical videos, providing a data-driven interactive environment for robotic ultrasound data acquisition and policy evaluation.

Closest papers

Nearest neighbours by meaning across the whole index.

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

cs.CV cs.RO ·2026-10-07 ·Keke Yang, Erqi Wang, Sainan Guan, Hongliang Ren
code/data similarity 0.81
Abstract

World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29\% and 38\%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.

0.30

Scanning While Imagining: A Scene-Graph World Model for Robotic Ultrasound Navigation

cs.RO cs.AI ·2026-09-26 ·Xuesong Li, Shuai Chen, Feng Li, Zhongliang Jiang, Nassir Navab +1 more
code/data similarity 0.72
Abstract

Ultrasound (US) acquisition depends on the operator's ability to interpret anatomy and anticipate how the view will change with probe motion. Many robotic US navigation methods select actions without explicitly predicting these anatomical changes. We propose SonoGraph-WM, an action- and goal-conditioned world model for anticipatory probe navigation. The model represents anatomy as scene graphs (SGs), capturing visible structures, their geometry, and spatial relationships without synthesizing US images. Given a history of SGs and probe poses, a unified Transformer jointly predicts future SGs and poses. A receding-horizon planner recursively imagines candidate trajectories, selects the shortest predicted path reaching a goal graph, and follows it over a short execution horizon before replanning from new observations. To reduce reliance on tracked and anatomically annotated US sequences, we generate aligned SG--pose training data from computed tomography (CT) label maps along surface-constrained probe trajectories. On four held-out CT cases, spatial relation F1 remains above 93% over 20 prediction steps, and closed-loop navigation achieves 77.50% and 75.00% success for the gallbladder and pancreas, respectively, using annotation-derived SGs. In robot--phantom navigation experiments with label-map-derived SGs, the planner reached the target view in 73.7% of trials. These findings support CT-supervised anatomical world modeling for probe planning and highlight the importance of frequent observation updates for reliable navigation. Project Page: https://noseefood.github.io/us-sonograph-wm/

0.35

Recon2Servo: Robotic Ultrasound Visual Servoing via Learned Image-to-Motion Inference

cs.RO ·2026-10-05 ·Yameng Zhang, Pei Liu, Dianye Huang, Yizhao Qian, Zhongyu Chen +3 more
similarity 0.71
Abstract

Ultrasound visual servoing is essential for autonomous robotic ultrasound, yet 6-DoF probe control from 2D B-mode images remains challenging due to limited and ambiguous out-of-plane motion cues. Existing methods typically rely on anatomical priors or handcrafted visual features, limiting their generalizability across imaging targets. Inspired by trackerless 3D ultrasound reconstruction, we propose Recon2Servo, a visual servoing framework that learns image-to-motion inference directly from B-mode images for 6-DoF probe control. A DINOv3 encoder with low-rank adaptation and a bidirectional relation module estimate the relative probe pose between current and target images to guide iterative closed-loop target-view alignment. The framework combines supervised relative-pose learning, reconstruction-guided closed-loop adaptation, and bounded residual pose correction to improve motion inference during servoing. Evaluations on a public dataset and an in-house dataset collected from 12 healthy volunteers using different ultrasound systems demonstrate its effectiveness in reconstructed-volume servoing. Additional real-robot demonstrations of target-view alignment and dynamic tracking on a human forearm are provided in the supplementary video: https://youtu.be/qwsOdI-GMYk.

0.29

Ultrasound Operator Guidance Using World Modeling and Retrieval Based Action Planning

cs.LG cs.CV ·2026-10-05 ·Noortje I. P. Schueler, Hans van Gorp, Ruud J. G. van Sloun
similarity 0.70
Abstract · 11 pages, 8 figures, 5 tables

Ultrasound is widely used, but acquisition quality is heavily dependent on the operator's knowledge and expertise. With demand for examinations outpacing the supply of trained sonographers, operator-guidance systems aim to close this gap by instructing a less trained user how to move the probe toward a target view. In this paper, we propose a retrieval-induced latent transition model for ultrasound acquisition dynamics, formulating ultrasound operator guidance as multi-step planning and retrieval in a world model. Using a V-JEPA 2.1 backbone, observations are first encoded into a latent space where anatomically related views lie close together. We then retrieve similar views from a reference database containing encoded latent states and corresponding probe positions and orientations. Rather than learning a parametric transition function, we directly use physically executed transitions from the database to establish our nonparametric, retrieval-induced transition model that supports receding-horizon planning. At deployment, guidance is generated from the live ultrasound image feed alone, without any probe tracking hardware. Applied to carotid ultrasound, the proposed planner reaches the target view in 86% of retrospective closed-loop episodes, versus 52% and 43% for representative baselines, outperforming both on every target view, including the challenging longitudinal internal and external carotid artery views. A prospective feasibility study on unseen volunteers, run in real time on a CPU using distillation, reaches 83% target-view reachability. Because planning is driven by proximity to any encodable goal latent, the same world model can navigate back to any previously acquired, patient-specific frame, supporting reproducible longitudinal imaging for e.g. perioperative or follow-up monitoring.

0.20

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

cs.RO cs.CV ·2026-08-17 ·Cheng Zhang, Xingzheng Wu, Guihao Yan, Xifeng Hu, Zhi Liu +2 more
top venuedatasetcode/data similarity 0.69
Abstract

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.

0.51

Cycle WAM: Coupling Action and Video through Cycle Consistency

cs.CV cs.AIcs.RO ·2026-11-03 ·Qinglin Yang, Jiepeng Wang, Yuxing Huang, Haibin Huang, Kai Xu +3 more
similarity 0.69
Abstract

Recent advances in video modeling have driven substantial progress in world action models (WAMs). Existing approaches exploit pretrained video priors by decoding actions from latent representations or inferring them from generated videos. The underlying link is causal: robot actions produce changes in the scene, and video observations of these changes provide evidence for inferring the actions that produced them. However, existing training formulations do not by themselves ensure that actions and their predicted visual consequences are consistent, potentially limiting the use of pretrained capabilities. We treat video and action as paired modalities linked by this causal relationship and learn their correspondence through a unified training framework designed to better exploit pretrained video priors. Cycle WAM first augments video-action co-training with bidirectional conversion to reinforce cross-modal correspondence and recover forward and inverse dynamics. It then introduces a differentiable cycle-reconstruction objective to further couple the two mappings. The resulting model supports both forward and inverse dynamics, with the potential to improve performance through more effective use of pretrained video priors. Cycle WAM achieves state-of-the-art performance among comparable methods on LIBERO-Pro and substantially improves DreamZero on DROID. Comparisons with UWM characterize its inverse-dynamics performance and show sharper visual detail in the displayed forward-dynamics predictions.

0.07

Video World Models Need Predictable Latents

cs.LG cs.AIcs.CVcs.RO ·2026-10-26 ·Mattia Scardecchia, Sherry Yang
code/data similarity 0.68
Abstract · 54 pages, 25 figures, 14 tables. Code: https://github.com/mattia-scardecchia/predictable-latents

Video world models trained on large-scale robot data promise a safe and scalable approach for learning and evaluating policies that act in the physical world. However, they still struggle with long-horizon rollouts and out-of-distribution generalization, and they remain computationally demanding at inference time. Typically, video world models make predictions in the latent space of a reconstruction-trained autoencoder, which however is not directly optimized for dynamics modeling. On the other hand, world models designed for latent planning usually optimize latents to be predictable, but they forgo accurate prediction of observations in pixel space. In this paper, we show that it is possible to achieve the best of both worlds: a latent geometry optimized to make future prediction as simple as possible without sacrificing accurate prediction of future observations. More precisely, we find that temporal objectives for representation learning, paired with a past-conditioned decoder architecture, lead to consistent improvements in generative video world models at the same training budget. The gains include up to 5x cheaper inference, over 7x faster training, and 15-24% lower pixel and perceptual errors out of distribution and over long horizons. Our world models also agree more closely with real-world policy evaluation when using a vision-language model to judge task success from their pixel-space predictions. Overall, our study indicates that temporal predictability is an important design criterion for the latent space of video world models, and provides concrete guidance on how to incorporate it into the training of autoencoders.

0.22

From Freehand Demonstrations to Autonomous Robotic Ultrasound: An Anatomy-Anchored Learning Framework

cs.RO ·2026-10-23 ·Yuan Bi, Fangxu Han, Ye Su, Yiping Zhou, Zhongliang Jiang +1 more
similarity 0.67
Abstract

Ultrasound imaging is highly operator-dependent, motivating robotic systems that reproduce expert scanning skills consistently. These skills involve coordinated interpretation of anatomical landmarks, ultrasound images, and probe-tissue interactions that are difficult to encode in hand-designed control strategies. Imitation learning offers an alternative, but its observation and action representations should reflect the anatomically structured nature of scanning. We propose an anatomy-anchored imitation-learning framework that combines anatomy-guided probe placement with learned ultrasound navigation. The placement module identifies a task-specific anatomical starting point from external visual observations and establishes the initial probe pose as the reference frame for scanning. A flow-based policy then generates scanning motions from anchor-relative probe poses, ultrasound images, probe-mounted camera views, and contact forces, while a termination head predicts task completion. This avoids continuous reliance on third-person vision and reduces dependence on the robot-patient configuration. A handheld acquisition platform enables multimodal demonstrations to be collected during natural freehand scanning without a robot. On 16 unseen participants, task success reaches 96%, 94%, 88%, and 94% for kidney, gallbladder, and liver standard-plane acquisition and radial artery sweeping, respectively. Compared with a fine-tuned pi_0 model, success on the abdominal tasks improves by 10-42 percentage points, with lower time-to-target, peak contact force, and trajectory jerk. Ablations support the complementary roles of anatomical anchoring, egocentric vision, and force feedback. End-to-end trials with automatic placement achieve 90-100% success, and the policies transfer without retraining to a second robot with 83-100% success.

0.07