CS Paper Radar

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

Cheng Zhang, Xingzheng Wu, Guihao Yan, Xifeng Hu, Zhi Liu, Mei Wu, Qing Cai

cs.RO cs.CV ·submitted 2026-08-17 04:12 UTC · v1
top venuedatasetcode/data

Abstract

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.

Closest papers

Nearest neighbours by meaning across the whole index.

From Freehand Demonstrations to Autonomous Robotic Ultrasound: An Anatomy-Anchored Learning Framework

cs.RO ·2026-10-23 ·Yuan Bi, Fangxu Han, Ye Su, Yiping Zhou, Zhongliang Jiang +1 more
similarity 0.76
Abstract

Ultrasound imaging is highly operator-dependent, motivating robotic systems that reproduce expert scanning skills consistently. These skills involve coordinated interpretation of anatomical landmarks, ultrasound images, and probe-tissue interactions that are difficult to encode in hand-designed control strategies. Imitation learning offers an alternative, but its observation and action representations should reflect the anatomically structured nature of scanning. We propose an anatomy-anchored imitation-learning framework that combines anatomy-guided probe placement with learned ultrasound navigation. The placement module identifies a task-specific anatomical starting point from external visual observations and establishes the initial probe pose as the reference frame for scanning. A flow-based policy then generates scanning motions from anchor-relative probe poses, ultrasound images, probe-mounted camera views, and contact forces, while a termination head predicts task completion. This avoids continuous reliance on third-person vision and reduces dependence on the robot-patient configuration. A handheld acquisition platform enables multimodal demonstrations to be collected during natural freehand scanning without a robot. On 16 unseen participants, task success reaches 96%, 94%, 88%, and 94% for kidney, gallbladder, and liver standard-plane acquisition and radial artery sweeping, respectively. Compared with a fine-tuned pi_0 model, success on the abdominal tasks improves by 10-42 percentage points, with lower time-to-target, peak contact force, and trajectory jerk. Ablations support the complementary roles of anatomical anchoring, egocentric vision, and force feedback. End-to-end trials with automatic placement achieve 90-100% success, and the policies transfer without retraining to a second robot with 83-100% success.

0.07

Ultrasound Operator Guidance Using World Modeling and Retrieval Based Action Planning

cs.LG cs.CV ·2026-10-05 ·Noortje I. P. Schueler, Hans van Gorp, Ruud J. G. van Sloun
similarity 0.75
Abstract · 11 pages, 8 figures, 5 tables

Ultrasound is widely used, but acquisition quality is heavily dependent on the operator's knowledge and expertise. With demand for examinations outpacing the supply of trained sonographers, operator-guidance systems aim to close this gap by instructing a less trained user how to move the probe toward a target view. In this paper, we propose a retrieval-induced latent transition model for ultrasound acquisition dynamics, formulating ultrasound operator guidance as multi-step planning and retrieval in a world model. Using a V-JEPA 2.1 backbone, observations are first encoded into a latent space where anatomically related views lie close together. We then retrieve similar views from a reference database containing encoded latent states and corresponding probe positions and orientations. Rather than learning a parametric transition function, we directly use physically executed transitions from the database to establish our nonparametric, retrieval-induced transition model that supports receding-horizon planning. At deployment, guidance is generated from the live ultrasound image feed alone, without any probe tracking hardware. Applied to carotid ultrasound, the proposed planner reaches the target view in 86% of retrospective closed-loop episodes, versus 52% and 43% for representative baselines, outperforming both on every target view, including the challenging longitudinal internal and external carotid artery views. A prospective feasibility study on unseen volunteers, run in real time on a CPU using distillation, reaches 83% target-view reachability. Because planning is driven by proximity to any encodable goal latent, the same world model can navigate back to any previously acquired, patient-specific frame, supporting reproducible longitudinal imaging for e.g. perioperative or follow-up monitoring.

0.20

ForceU-VLA: A Force-Aware Vision-Language-Action Model for Embodied Ultrasound Scanning

cs.RO cs.CV ·2026-08-15 ·Xingzheng Wu, Cheng Zhang, Guihao Yan, Xifeng Hu, Zhi Liu +1 more
top venuecode/data similarity 0.74
Abstract

Embodied intelligent ultrasound scanning enables the automation and standardization of the ultrasound examination process by integrating perception, decision-making, and execution capabilities. However, existing methods suffer from loosely coupled modeling between force and ultrasound modalities and lack awareness of scanning stages, which limits their ability to capture dynamic probe-tissue interactions. To address these issues, we propose ForceU-VLA, a force-aware Vision-Language-Action model for autonomous embodied ultrasound scanning, which leverages force signals and ultrasound image feedback throughout the scanning process to enable accurate and high-quality ultrasound acquisition. Firstly, we propose a Force-Ultrasound Synergistic Fusion Module (FUSFM) that synergistically fuses ultrasound visual and force-feedback information to provide stable, reliable guidance for probe motion. Secondly, a Stage-Adaptive Modulation Mechanism (SAMM) is proposed to accommodate the task requirements across different scanning stages by adaptively modulating multimodal features to enhance their representation quality. Additionally, we introduce ForceU-VLA-Data, a real-world, force-aware embodied ultrasound dataset that integrates visual, force, and action signals, including data from two organs across five representative clinical scanning views, and comprising 450 expert-collected trajectories with approximately 100,000 synchronized multimodal frames. Extensive experimental results demonstrate that ForceU-VLA significantly improves contact stability and probe pressure regulation in embodied ultrasound scanning, thereby effectively enhancing task execution quality and overall system reliability. The source code is available at https://github.com/VMVLab/ForceU-VLA.

0.54

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

cs.CV cs.RO ·2026-10-07 ·Keke Yang, Erqi Wang, Sainan Guan, Hongliang Ren
code/data similarity 0.73
Abstract

World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29\% and 38\%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.

0.30

SonoWorld: Towards Interactive Pose-Controllable Ultrasound World Models

cs.CV ·2026-10-14 ·Zefan Yang, Zheyuan Zhang, Boris Maihe, Yikang Liu, Hang Yu +5 more
similarity 0.69
Abstract

Robotic ultrasound can standardize image acquisition and reduce operator workload and variability, but policy learning remains limited by the lack of realistic, controllable simulation environments. While controllable world models have advanced rapidly in natural-image domains, ultrasound world modeling remains challenging because each frame captures only a cross-section of unobserved 3D anatomy, causing small probe motions to induce large appearance changes. Existing approaches rely on robot-tracked poses and latent-space prediction, but do not directly generate the observations required for interactive control. We propose SonoWorld, a causal ultrasound world model that learns video dynamics from unlabeled clinical videos and grounds them to 6-DoF control using a small set of freehand clinical scans tracked with an EM sensor. SonoWorld is trained in three stages: pretraining a latent-action-conditioned video diffusion model on around 6.9 million unlabeled multi-organ ultrasound frames; grounding the learned video dynamics to metric probe poses with a small EM-tracked thyroid dataset; and applying distribution matching distillation to enable causal, long-horizon autoregressive generation with selectively caching eviction tokens at inference time. We evaluate controllability through pose-following fidelity, round-trip consistency, and axis-specific control under synthetic actions on held-out tracked scans, and further validate it with a user study. In model-based action discrimination, SonoWorld correctly ranks the target-directed probe motion over an equal-magnitude opposite motion in up to 74.8% of trials. To our knowledge, SonoWorld is the first causal, pose-controllable ultrasound world model learned primarily from freehand clinical videos, providing a data-driven interactive environment for robotic ultrasound data acquisition and policy evaluation.

0.08

StellaVLA: In-Context Structured Demonstration for Generalizable Vision-Language-Action Models

cs.RO ·2026-08-12 ·Siyu Xu, Yunke Wang, Zijian Wang, Dihao Zhu, Chenghao Xia +4 more
benchmark similarity 0.67
Abstract

Vision-Language-Action (VLA) models can follow instructions and manipulate objects, but their performance often collapses out of distribution (OOD), when the scene, viewpoint, or object differs from training. Adapting to each new situation typically requires collecting more data and fine-tuning. We present StellaVLA, a framework that instead adapts at test time by conditioning on a single retrieved demonstration. The key idea is to move beyond imitating what an expert did and instead convey why: an automated offline pipeline converts each raw trajectory into a structured demonstration, e.g., a task plan, sub-goal descriptions, and verbalized 3D motion, at zero human-annotation cost. Provided as in-context guidance, this structured demonstration lets the policy reason about the task rather than mimic a pixel trajectory, which also makes it transferable across embodiments (real-robot, human-hand, or XR demonstrations). A parallel dual-training design internalizes this reasoning during training through a joint action-and-language objective, while inference uses the action expert alone, preserving real-time, high-frequency control with no added latency. On the VLA-Arena leaderboard(Aug 1, 2026), StellaVLA ranks first with an overall score of 0.63, versus 0.44 and 0.22 for the strong prior models ($π_{0.5}$ and LingBot-VLA), and it further leads on LIBERO with 98.8% average success rate and LIBERO-Plus with 85.1% success rate. Our real-robot benchmark demonstrates that StellaVLA can use both human/robot demos and human-to-robot (XR) demos as in-context structured demonstration to help VLA model adapt to OOD tasks.

0.41

Boot-and-Feedback Framework for Generalist-Expert Model Collaboration in Breast Ultrasound Diagnosis

cs.CV cs.MM ·2026-08-25 ·Ming Cheng, Hongyu Sun, Zhaolin Chen, Jun Liu, Hossein Rahmani +1 more
published similarity 0.67
Abstract · 5 pages, 2 figures. Published in ICASSP 2026

Breast ultrasound (BUS) is widely used for breast cancer diagnosis yet remains operator-dependent. While deep learning shows promise, ensuring diagnostic reliability and interpretability is challenging. Recent Multimodal Large Language Models (MLLMs) often generate spurious descriptions due to limited domain knowledge, which mislead downstream expert models and compromise clinical validity. To address these challenges, we propose the Boot-and-Feedback (BooF) model collaboration framework for synergistic MLLM-expert interaction. Specifically, in the Boot Stage, the MLLM is guided by the BI-RADS lexicon and preliminary benign-malignant vision-expert predictions, enabling it to transfer general reasoning to BUS analysis while avoiding hallucinations. Subsequently, the Feedback Stage integrates these descriptions with visual features via a lightweight Attention-Gated Cross-Modality Fusion Module. This allows the expert to leverage textual feedback while adaptively filtering noise. Extensive experiments on multiple BUS datasets demonstrate that BooF substantially outperforms state-of-the-art methods in terms of diagnostic accuracy and interpretability.

0.52

Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

cs.CV cs.AI ·2026-10-08 ·Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng +1 more
publishedbenchmarkcode/data similarity 0.66
Abstract · Accepted to BMVC 2026. Code: https://github.com/NiHaoWoJiaoYYC/CAMEO

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USReport-Distilled with 17,670 evidence-grounded paired-image training instances and USReport-Pref with 21,869 preference pairs; we additionally use 25,631 PubMedVision-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USReport-Distilled benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation.

0.45