CS Paper Radar

Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng, Yuqing Yang

cs.CV cs.AI ·submitted 2026-10-08 09:53 UTC · v1
publishedbenchmarkcode/data

Abstract

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USReport-Distilled with 17,670 evidence-grounded paired-image training instances and USReport-Pref with 21,869 preference pairs; we additionally use 25,631 PubMedVision-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USReport-Distilled benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation.

Comment
Accepted to BMVC 2026. Code: https://github.com/NiHaoWoJiaoYYC/CAMEO

Closest papers

Nearest neighbours by meaning across the whole index.

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

cs.RO cs.CV ·2026-08-17 ·Cheng Zhang, Xingzheng Wu, Guihao Yan, Xifeng Hu, Zhi Liu +2 more
top venuedatasetcode/data similarity 0.66
Abstract

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.

0.51

UltraWorld: Learning Interactive Ultrasound World Models from Untracked Clinical Videos with Acoustic Sampling Map

cs.CV cs.RO ·2026-10-07 ·Keke Yang, Erqi Wang, Sainan Guan, Hongliang Ren
code/data similarity 0.66
Abstract

World models can enable autonomous ultrasound scanning by predicting the outcomes of probe motions from local observations. Learning this action--observation relationship typically relies on synchronized video--pose pairs, which are costly to collect at scale and largely unavailable in routine clinical recordings. Reliable action following further requires modeling ultrasound's cross-sectional sampling geometry. We present UltraWorld, a self-distillation recipe that transfers priors from clinical ultrasound videos into interactive world models without real action annotations. Starting from clinical videos, we adapt a video foundation model into an ultrasound generator conditioned on reference images and anatomical masks. Anatomical masks sampled along programmable trajectories through 3D anatomy provide spatial guidance for synthesizing action--video pairs. We then use these synthetic pairs to self-distill the generator into a world model that predicts future observations from local observations and actions, without requiring anatomical masks or other 3D assets at inference time. To further improve action following, we introduce the Acoustic Sampling Map (AsMap), which represents probe poses and imaging settings as pixel-wise 3D sampling positions, beam directions, and depths. Experiments demonstrate improved prediction fidelity and action following. Across nine simulated closed-loop local planning episodes, UltraWorld reduces the mean final distance to the goal and orientation error by 29\% and 38\%, respectively, compared with visual servoing. Project Page: https://ultraworld-project.github.io/.

0.30

SonoWorld: Towards Interactive Pose-Controllable Ultrasound World Models

cs.CV ·2026-10-14 ·Zefan Yang, Zheyuan Zhang, Boris Maihe, Yikang Liu, Hang Yu +5 more
similarity 0.65
Abstract

Robotic ultrasound can standardize image acquisition and reduce operator workload and variability, but policy learning remains limited by the lack of realistic, controllable simulation environments. While controllable world models have advanced rapidly in natural-image domains, ultrasound world modeling remains challenging because each frame captures only a cross-section of unobserved 3D anatomy, causing small probe motions to induce large appearance changes. Existing approaches rely on robot-tracked poses and latent-space prediction, but do not directly generate the observations required for interactive control. We propose SonoWorld, a causal ultrasound world model that learns video dynamics from unlabeled clinical videos and grounds them to 6-DoF control using a small set of freehand clinical scans tracked with an EM sensor. SonoWorld is trained in three stages: pretraining a latent-action-conditioned video diffusion model on around 6.9 million unlabeled multi-organ ultrasound frames; grounding the learned video dynamics to metric probe poses with a small EM-tracked thyroid dataset; and applying distribution matching distillation to enable causal, long-horizon autoregressive generation with selectively caching eviction tokens at inference time. We evaluate controllability through pose-following fidelity, round-trip consistency, and axis-specific control under synthetic actions on held-out tracked scans, and further validate it with a user study. In model-based action discrimination, SonoWorld correctly ranks the target-directed probe motion over an equal-magnitude opposite motion in up to 74.8% of trials. To our knowledge, SonoWorld is the first causal, pose-controllable ultrasound world model learned primarily from freehand clinical videos, providing a data-driven interactive environment for robotic ultrasound data acquisition and policy evaluation.

0.08

C$^2$LUE: Clinically Aligned Patient-Level Ultrasound Diagnosis via Evidence-Aware Multi-Instance Learning

eess.IV cs.CV ·2026-10-09 ·Qin-Yi Zhang, Linying Cao, De-Xing Huang, Haichuan Lin, Yi Yang +5 more
similarity 0.65
Abstract

Patient-level ultrasound diagnosis demands not only high predictive accuracy but also clinically aligned mitigation of asymmetric diagnostic risks. While Multi-Instance Learning (MIL) effectively models routine multi-view exams, standard aggregators often dilute heterogeneous diagnostic cues and optimize solely for global accuracy. This frequently yields undesirable sensitivity-specificity trade-offs. To bridge this gap, we propose C$^2$LUE, a novel MIL framework coupling evidence aware aggregation with risk-aligned regularization. To preserve evidence heterogeneity and prevent unimodal attention collapse, C$^2$LUE employs a multi-query cross-attention mechanism built upon a LoRA-adapted DINOv3 backbone. Multiple latent queries explicitly extract and disentangle diverse morphological patterns from the ultrasound sequence. Furthermore, to improve clinical risk alignment, we introduce a dynamic trade-off regularization objective that penalizes sensitivity-specificity imbalance during training. Rather than leaving the clinical trade-off entirely to post-hoc threshold adjustment, this objective encourages the learned score distribution toward a more balanced operating region. Extensive evaluations on patient-level, biopsy-proven thyroid and breast ultrasound datasets demonstrate that C$^2$LUE consistently outperforms prior alternatives. By uniting strong discrimination with a balanced error profile, C$^2$LUE provides a promising solution for real-world ultrasound screening and diagnosis.

0.21

PACER: Progressive Availability-Conditioned Evidence Routing for Radiology Report Generation under Incomplete Clinical Context

cs.CV ·2026-09-28 ·Yulong Chen, Yadong Liu, Haoyu Cao, Sen Xu, Yueying Wang +1 more
similarity 0.65
Abstract · 23 pages, 2 figures, 7 tables

Radiology report generation (RRG) increasingly incorporates heterogeneous clinical evidence, such as multi-view radiographs and previous reports, whose availability varies across examinations. However, accommodating different input combinations does not ensure effective evidence use: generated reports may still omit or inaccurately describe clinically relevant findings. To address this problem, we propose PACER, a Progressive Availability-Conditioned Evidence Routing framework for structured incomplete-context RRG that follows a Refine-Calibrate-Commit pipeline. It first refines observed visual representations through endpoint-preserving patchwise routing across frozen encoder depths, incorporating complementary cues while retaining the pretrained terminal representation. It then calibrates the language-model prefix according to the observed evidence and availability state, adapting the shared generator's conditioning as the available source set changes. Finally, it generates polarity-structured clinical commitments before the report in the same autoregressive trajectory, providing structured clinical context for subsequent generation. Experiments demonstrate state-of-the-art clinical efficacy across all four MIMIC-RG4 settings and strong MIMIC-CXR performance, while maintaining competitive language-generation quality.

0.32

UltraG-Bench: A Multi-task Benchmark for assessing Large Vision-Language Models on Pixel-level Evidence Grounding in Ultrasound

cs.CV cs.AI ·2026-09-25 ·Quanhao Zhu, Bo Xu, Rui Lin, Chenyuan Wang, Yu Shao +5 more
benchmarkcode/data similarity 0.65
Abstract

Ultrasound is one of the most widely used medical imaging modalities, and recent large vision-language models(VLMs) have shown increasing capabilities in ultrasound image understanding. However, these models fail to provide pixel-level visual evidence aligned with their semantic predictions, and their fine-grained grounding capability in ultrasound remains largely unclear. We introduce UltraG-Bench, a large-scale multi-task benchmark for evaluating pixel-level evidence grounding in ultrasound. UltraG-Bench is built by annotating 40 public ultrasound segmentation datasets spanning 13 anatomical categories, and comprises three progressive tasks: instruction-guided segmentation, evidence-grounded VQA, and evidence-grounded report generation, with 331125, 666779, and 138832 annotations, respectively. Comprehensive evaluation of 14 state-of-the-art models reveals a substantial gap between semantic understanding and fine-grained pixel-level localization. We further propose UltraG-Agent, which combines the semantic reasoning capabilities of a VLM with the ultrasound-specific segmentation capability of UltraSAM3. Experiments show that UltraG-Agent substantially improves both semantic prediction and pixel-level visual grounding. Our dataset and code are available at https://github.com/zhuqh19/UltraG-Bench.

0.60

Interleaving anatomical inspection and diagnostic reasoning for explainable radiology report generation

cs.CV cs.AI ·2026-11-10 ·Chentao Huang, Runlong Lin, Zhijun Wang, Yunxiang Li, Yuanyuan Sun +3 more
similarity 0.65
Abstract

Automated radiology report generation can draft clinically plausible reports, yet the pathway from visual evidence to reported findings remains opaque, leaving the diagnostic basis of these reports unexplained and the generated reports difficult to review or revise. We introduce ARIVE (Anatomy-guided Reasoning with Interleaved Visual Evidence), an explainable report generation framework that interleaves anatomical inspection with diagnostic reasoning prior to final report composition. To support this process, we constructed 159,416 multimodal chain-of-thought (MCoT) trajectories from MIMIC-CXR, wherein visual evidence from inspected anatomical regions informs subsequent clinical interpretation. Trained on these trajectories and further optimized using anatomical and clinical-content rewards, ARIVE achieved superior clinical-efficacy performance compared with strong baselines on MIMIC-CXR and the abnormality-centered MIMIC-ABN. ARIVE's reports were competitive with those of leading models in blinded expert grading, and its MCoT trajectories earned high ratings for diagnostic traceability. Furthermore, a paired review evaluation suggests that access to MCoT can aid in identifying errors within generated reports.

0.15

SMILE: A Structured Multi-Agent Clinical Reasoning for Liver Ultrasound Understanding

cs.CV cs.CLcs.LG ·2026-11-02 ·Haris Ghafoor, Minjee Seo, Seonaeng cho, Keungmo Yang, Jaejun Lee +1 more
publishedcode/data similarity 0.64
Abstract · Accepted at Winter Conference on Applications of Computer Vision (WACV) 2027

Automated liver ultrasound report generation improves the diagnosis of liver diseases by producing clinically structured descriptions of anatomical and disease-related findings. However, current generative vision-language models (VLMs) often rely on a single reasoning pathway that maps ultrasound appearance directly to textual descriptions. In addition to the inherent vision-language modality gap, this design is limited for liver ultrasound because disease interpretation is constrained by subtle visual evidence, heterogeneous disease patterns, and limited paired supervision. To address these limitations, we propose SMILE, a Structured Multi-agent clInicaL rEasoning framework that uses multiple complementary specialist agents to interpret ultrasound images and consolidates their outputs through a judge-guided consensus mechanism. Our approach employs three specialized agents: an image interpretation agent for morphological descriptions, a clinical-stage reasoning agent, and a visual question answering (VQA) agent for targeted queries. These agent responses are then aggregated and scrutinized by a judge VLM using a consensus filtering prompt to produce a unified, clinically coherent output. Across a public liver ultrasound dataset and an internal clinical dataset, SMILE consistently outperforms state-of-the-art VLMs, achieving up to 19.0\% improvement in ROUGE-1 and 18.8\% improvement in clinical F1-score, while reaching VQA F1-scores of 0.82 and 0.65 on public and internal datasets, respectively. These results demonstrate the potential of SMILE for data-scarce and limited-supervision clinical settings. Our models, datasets, and code are available \href{https://github.com/CMME-Lab/SMILE}{here}.

0.42