Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

Closest papers

Nearest neighbours by meaning across the whole index.

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

cs.RO ·2026-10-08 ·Ehsan Nasiri, Yi Zheng, Michael A. Kokko, Xiaoyao Fan, William R. Warner +2 more
similarity 0.69
Abstract · Submitted to the ASME Journal of Mechanisms and Robotics; currently under review

This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

0.24

Augmenting Real-time Visualization in Minimally Invasive Surgery with Particle Filtering and Depth-Aware Occlusion Handling

eess.IV cs.RO ·2026-10-13 ·Anuska Sarkar, Partha Acharya, Vishnu Nandury, Kaustav Basu, Subhamoy Mandal
top venue similarity 0.66
Abstract · Accept

We present a real-time, hybrid framework for occlusion handling and depth-aware tracking in minimally invasive surgeries (MIS). Occlusions caused by surgical instruments often obscure the region of interest (ROI), affecting surgical precision. To address this, our approach integrates enhanced You Only Look Once (YOLO) based detection, Particle Filtering (PF), and monocular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation against stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.

0.31

Visual Cue Interactions in AR-Guided Needle Insertion: A Prostate Biopsy-Inspired Phantom Study

cs.GR ·2026-08-27 ·Xinrui Zou, Mingxu Liu, Thomas T. Jones, Braden Millan, Sandeep Gurram +3 more
published similarity 0.65
Abstract · Accepted at IEEE ISMAR 2026. The definitive version will be available in IEEE Xplore

Despite the apparent simplicity of the motor action involved during percutaneous needle procedures, manipulating the tool's direction becomes challenging when clinicians cannot directly visualize internal anatomy and must rely on ultrasound images, which increase cognitive demand. Augmented reality (AR) offers the promise to assist with these tasks by providing pertinent visual information in the clinician's field of view. However, simply providing visual information that ignores meaningful visual cues can complicate depth perception and spatial understanding. In this work, we introduce and evaluate three visualization techniques for needle alignment developed during design sessions with medical experts: a localized focus-and-context window, a color-based proximity encoding, and an explicit trajectory overlay. These techniques were evaluated in a user study (n=26) including clinical experts (n=7) using a prostate-biopsy-inspired phantom. Results from this study suggest that cue effects depended on the surrounding cue configuration and user expertise. For novices, explicit trajectory overlay improved targeting accuracy and reduced retreat behavior, but its effect on completion time varied across cue configurations, with slower performance when the overlay was presented alone. For experts, the focus-and-context window reduced completion time and retreat events, while color-based proximity overlay improved completion time. Subjectively, color cues were often perceived as helpful even when their effects on accuracy were not consistent. These results suggest that AR guidance strategies for percutaneous interventions should consider user expertise and visual context.

0.41

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.63
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

An Anatomy-guided 3D Segmentation Pipeline for Prostate Surgical Phantoms from CT Scans

cs.CV ·2026-11-05 ·Iven Chen, Kuan-I Chung, Ayberk Acar, Susheela Sharma Stern, Alejandro O. Chara +2 more
similarity 0.62
Abstract · 11 pages, 2 figures, 3 tables, 10 algorithms. Extended abstract accepted at SPIE Medical Imaging 2027: Image Processing

Full autonomy has been a long-term goal in robotic surgery and a near-to-medium-term goal for prostatectomy. Due to the relatively closed structure of the procedure, its standard-of-care robotic/laparoscopic solutions, and procedure economics, prostate procedures are an optimal early target for surgical automation. Prototyping and testing of possible solutions is done in constructed laboratory phantoms, either synthetic tissues or animal phantoms. To enable measurement of perceptual and robotic motion error, phantoms undergo volumetric imaging; these images are critical to both a potential deployed automatic system, used in planning motion and treatment (cutting, ablation, suturing, etc.), as well as post-hoc assessment of system performance. Rapid iteration on these phantom models yields small, inconsistent datasets, while the current workflow for human annotation is often anatomically unreliable and prohibitively time-consuming, rendering deep learning unsuitable at reasonable scales. To address these limitations, we present an automated 3D segmentation pipeline that uses classical medical image-processing techniques to encode the known anatomy of the phantoms as explicit geometric and intensity priors, which requires no training corpus and is transferred to each new phantom revision without re-annotation. Across 57 scans spanning multiple phantom revisions, our pipeline recovers the capsule interior at 0.83 median Dice on 11 contrast-suppressed scans and detects all 32 annotated focal lesions without false positives, completing a full scan in 2-8 minutes on commodity CPU hardware versus 1-2 hours by hand.

0.35

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

cs.RO ·2026-09-22 ·Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei +3 more
published similarity 0.61
Abstract · 8 pages, 8 figures. Accepted to IROS 2026

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

0.41

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.61
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.

0.33

RAUL: Reference-Assisted Ureteroscopy Localization for Skill Assessment

cs.CV ·2026-09-16 ·Fangjie Li, Mai Bui, Charan Mohan, Michael Miga, Matthieu Chabanas +2 more
hot direction similarity 0.60
Abstract

Objective: Incomplete navigation of anatomy during ureteroscopic kidney stone surgeries can contribute to repeat interventions. While skilled surgeons have lower reintervention rates, there are no objective metrics to quantify scope-navigation performance to evaluate when a trainee becomes skilled. This work aims to recover ureteroscope trajectories from endoscopic video and derive navigation metrics to quantify differences in skill. Methods: We propose RAUL, a reference-assisted reconstruction framework for recovering ureteroscope trajectories from ureteroscope videos only in phantoms. For each phantom, we use a slow, high-quality reference exploration video to generate a reference reconstruction. We localize subsequent exploration videos against this reference. We evaluate localization accuracy against electromagnetically tracked scope pose. We compute navigation metrics from phantom exploration trajectories to compare surgical residents across experience levels. Results: The proposed reference-assisted framework achieves a mean translation root mean square error of $0.5 \pm 0.1$ mm across 9 phantoms. Compared to standard Structure-from-Motion (SfM), the proposed pipeline increases frame-wise localization coverage from $50.5 \pm 14.9\%$ to $86.1 \pm 7.2\%$ of all video frames. The reconstructed trajectories revealed significant differences between high- and low-experience trainees in established navigation metrics. Conclusion: RAUL enables substantially more complete recovery of ureteroscope trajectories from videos compared to standard SfM pipelines, enabling trajectory-based skill assessment without additional tracking equipment. Significance: To the best of our knowledge, this is the first use of video-only recovery of ureteroscope trajectories without external tracking sensors for skill assessment, supporting scalable automated assessment of ureteroscopy navigation skill.

0.38