CS Paper Radar

Augmenting Real-time Visualization in Minimally Invasive Surgery with Particle Filtering and Depth-Aware Occlusion Handling

Anuska Sarkar, Partha Acharya, Vishnu Nandury, Kaustav Basu, Subhamoy Mandal

eess.IV cs.RO ·submitted 2026-10-13 14:01 UTC · v1
top venue

Abstract

We present a real-time, hybrid framework for occlusion handling and depth-aware tracking in minimally invasive surgeries (MIS). Occlusions caused by surgical instruments often obscure the region of interest (ROI), affecting surgical precision. To address this, our approach integrates enhanced You Only Look Once (YOLO) based detection, Particle Filtering (PF), and monocular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation against stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.

Comment
Accept
Journal ref
IEEE Transactions on Medical Robotics and Bionics (T-MRB), October 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Semantic RGB--Depth Based Surgical Skill Assessment in Microscopic Stereo Videos

cs.CV ·2026-10-01 ·Jecia Z. Y. Mao, Sue M. Cho, Francis X. Creighton, Deepa Galaiya, Russell H. Taylor +1 more
similarity 0.69
Abstract

Objective assessment of microsurgical technical skill is essential for competency-based training and quality assurance, yet existing video-based approaches predominantly rely on RGB images and therefore overlook the 3D spatial relationships that characterize instrument-anatomy interactions. Although stereo operating microscopes provide complementary depth information, conventional stereo matching algorithms can produce sparse and unreliable depth estimates under high-magnification imaging conditions, limiting their use for automated skill assessment. This work presents a semantic RGB-Depth framework for surgical skill assessment from microscopic stereo videos. A regression-based depth fusion method combines sparse metric stereo depth with dense monocular depth estimates to generate a dense geometric representation of the surgical scene. This representation is integrated with semantically decomposed RGB streams corresponding to individual surgical instruments and surrounding anatomy. A hierarchical attention architecture jointly encodes these streams to capture discriminative patterns of instrument use and instrument-anatomy interaction across surgeons at different training levels. The framework was evaluated on 33 ex vivo transoral microlaryngeal procedures performed by six surgeons, comprising attending surgeons and surgical residents, using leave-one-surgeon-out cross-validation. The proposed semantic RGB-Depth model achieved an F1 score of 0.938 for skill-level classification, compared with 0.696 for semantic RGB and 0.929 for semantic depth. These results suggest that geometric information can improve automated surgical skill assessment from microscopic stereo videos. The learned spatial, temporal, and semantic attention patterns also support qualitative examination of the scene regions, video segments, and semantic streams emphasized by the model.

0.17

LARK: A Low-Cost, Accurate, Occlusion-Resilient, Kalman Filter-Assisted Tracking System for Image-Guided Surgery

cs.CV eess.IV ·2026-10-06 ·George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, Étienne Léger +1 more
similarity 0.68
Abstract · 24 pages, 15 figures, including appendices. Supplementary document included as an ancillary file. Supplementary video: https://youtu.be/ApZ8…

Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Commercial stereo infrared trackers are accurate but prone to occlusion and cost-prohibitive for many settings. This work presents LARK, a multi-camera optical tracking system using commodity RGB hardware and multi-view redundancy and fusion. We develop and evaluate two complete tracking methods: multi-view monocular pose fusion and multi-view triangulation. Both methods are assessed under varying occlusion levels using a precision-machined grid and an anatomical head phantom, and compared against a gold-standard stereo infrared system. With five cameras and adaptive Kalman filtering, LARK achieves median target registration errors of 0.64 mm for point localization with triangulation and 0.73 mm for trajectory tracking with pose fusion on the machined grid. Camera-subset experiments show graceful degradation in adaptive pose-fusion accuracy as fewer views remain available. With tracking hardware costing under $1,000 USD, LARK provides a low-cost platform for image-guided surgery research. Hardware designs and software are publicly available at https://nist.mni.mcgill.ca/software/ , and datasets at https://nist.mni.mcgill.ca/data/ .

0.25

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.68
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery

cs.RO ·2026-11-02 ·Yuxin Chen, Wenxuan Wang, Wanwen Chen, Qi Zeng, Septimiu E. Salcudean
similarity 0.66
Abstract

Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

0.28

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.65
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.

0.33

Object-Centered Reconstruction for Vision-Based 3D Force Estimation

cs.RO ·2026-09-20 ·Zhonghao Zhang, Mingyeung Wu, Hao Yang, Ayberk Acar, Alan Kuntz +1 more
similarity 0.64
Abstract

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

0.18

Semantic-Coupled Perception Framework for Autonomous Laparoscope Control

cs.RO eess.SY ·2026-10-25 ·Enduo Zhao, Fangzhou Li, Yujie Zhu, Sicheng Lu, Fang Chen +2 more
benchmark similarity 0.64
Abstract · 8 pages, 5 figures. Submitted to IEEE Robotics and Automation Letters (RA-L) for possible publication

In minimally invasive surgery (MIS), maintaining an appropriate field of view (FoV) is essential for surgical safety and efficiency. However, conventional autonomous laparoscope control methods often treat visual tracking and surgical phase recognition independently, limiting robustness under occlusion, entity overlap, and camera motion. This paper proposes a closed-loop autonomous laparoscope control framework that couples real-time surgical phase recognition with camera-motion-compensated visual perception. By exploiting phase-dependent relationships among surgical entities, the framework improves target state estimation under challenging visual conditions, supporting task-aware autonomous FoV control. Experiments on benchmark datasets evaluate the proposed framework in surgical phase recognition and target tracking, including scenarios involving occlusion and entity overlap. Phantom experiments further demonstrate the feasibility of autonomous FoV control, showing improved target visibility and task execution performance compared with fixed-FoV control. These results highlight the potential of incorporating task-level semantics into visual state estimation for autonomous laparoscope guidance.

0.18

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.64
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30