This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

Comment
Submitted to the ASME Journal of Mechanisms and Robotics; currently under review

Closest papers

Nearest neighbours by meaning across the whole index.

LARK: A Low-Cost, Accurate, Occlusion-Resilient, Kalman Filter-Assisted Tracking System for Image-Guided Surgery

cs.CV eess.IV ·2026-10-06 ·George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, Étienne Léger +1 more
similarity 0.71
Abstract · 24 pages, 15 figures, including appendices. Supplementary document included as an ancillary file. Supplementary video: https://youtu.be/ApZ8…

Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Commercial stereo infrared trackers are accurate but prone to occlusion and cost-prohibitive for many settings. This work presents LARK, a multi-camera optical tracking system using commodity RGB hardware and multi-view redundancy and fusion. We develop and evaluate two complete tracking methods: multi-view monocular pose fusion and multi-view triangulation. Both methods are assessed under varying occlusion levels using a precision-machined grid and an anatomical head phantom, and compared against a gold-standard stereo infrared system. With five cameras and adaptive Kalman filtering, LARK achieves median target registration errors of 0.64 mm for point localization with triangulation and 0.73 mm for trajectory tracking with pose fusion on the machined grid. Camera-subset experiments show graceful degradation in adaptive pose-fusion accuracy as fewer views remain available. With tracking hardware costing under $1,000 USD, LARK provides a low-cost platform for image-guided surgery research. Hardware designs and software are publicly available at https://nist.mni.mcgill.ca/software/ , and datasets at https://nist.mni.mcgill.ca/data/ .

0.25

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.70
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

An Interactive Mobile Augmented Reality System for Efficient Virtual Model-to-Patient Registration in Thoracic Surgery

cs.HC ·2026-10-27 ·Emmanuel Ajaero, Pascal Spiegler, George Rakovich, Marta Kersten-Oertal, Yiming Xiao
similarity 0.69
Abstract

Video-Assisted Thoracoscopic Surgery (VATS) is a minimally invasive procedure, where precise surgical port placement is vital, yet it relies heavily on surgeon experience and mental mapping of pre-operative imaging in the operating room. To address this challenge, we present an accessible, interactive mobile augmented reality (AR) framework, HILMARTS, to enable accurate and efficient pre-operative virtual model-to-patient registration for AR-guided surgical navigation. Our system runs on a commercially available LiDAR-equipped iPad and supports a user-in-the-loop workflow through a two-stage coarse-to-fine registration process. First, the user performs a manual alignment using the AR view on the iPad. This initial maneuver is then refined through automatic point-cloud registration leveraging the LiDAR sensor. We further introduce a novel occupancy-grid-based Surface Coverage Score to provide real-time, actionable feedback to the operator on the geometric completeness of LiDAR data capture for reliable point-cloud-based alignment. In a phantom study with 16 participants, the system achieved a 3.31+/-1.26mm registration accuracy in ~4 min with a mean System Usability Scale (SUS) of 84.1. These findings highlight the system's accuracy, efficiency, robustness, and potential clinical usability, and could support its applicability to other AR-based surgical navigation tasks.

0.11

Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery

cs.RO ·2026-11-02 ·Yuxin Chen, Wenxuan Wang, Wanwen Chen, Qi Zeng, Septimiu E. Salcudean
similarity 0.69
Abstract

Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

0.28

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

cs.RO ·2026-09-22 ·Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei +3 more
published similarity 0.67
Abstract · 8 pages, 8 figures. Accepted to IROS 2026

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

0.41

ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery

cs.RO ·2026-11-11 ·Jiawei Ge, Chunwoo Kim, Antony Goldenberg, Douglas McDonough, Justin Liao +16 more
code/data similarity 0.67
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution

Research on surgical autonomy needs open platforms that any laboratory can build, yet the most widely shared platform depends on donated clinical hardware, and open alternatives on industrial arms each lack part of the surgical chain. We present the Autonomous Robotic Translational System (ARTS), an open-source three-arm platform for autonomy research in minimally invasive surgery, built entirely from purchasable parts for about USD 137,000. Two UR5e arms hold wristed da Vinci X/Xi instruments, a UR5 arm holds a stereo endoscope with two FLIR cameras, the surgeon console provides haptic handles, footswitches and a stereo viewer, and a hardware stop independent of the software lets a supervisor freeze all three arms in place. The ROS 2 software pins every dependency, installs from the same scripts on bare metal or in containers, and records stereo images with hardware-measured timing. On the real arms, ARTS commands each arm at its controller's full rate (e.g., 500 Hz on the UR5e), the two cameras expose within 12 microseconds of each other, hand motion reaches the arm in 58 ms, and the endoscope image reaches the monitor in 68 ms. The ISO 9283 pose repeatability is 0.14-0.25 mm, comparable to a da Vinci Research Kit (dVRK) Classic arm on the same protocol, and an optical tracker measured a mean remote-center-of-motion error of 0.34-0.37 mm. Three expert and three novice operators performed the Fundamentals of Laparoscopic Surgery (FLS) peg transfer through a laparoscopic trainer box, and one of the experts sutured on a suture pad. The hardware designs, firmware and software are available at https://github.com/MRE-Lab-UMD/arts.

0.44

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.67
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.

0.33

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.66
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12