CS Paper Radar

An Interactive Mobile Augmented Reality System for Efficient Virtual Model-to-Patient Registration in Thoracic Surgery

Emmanuel Ajaero, Pascal Spiegler, George Rakovich, Marta Kersten-Oertal, Yiming Xiao

cs.HC ·submitted 2026-10-27 14:02 UTC · v1

Abstract

Video-Assisted Thoracoscopic Surgery (VATS) is a minimally invasive procedure, where precise surgical port placement is vital, yet it relies heavily on surgeon experience and mental mapping of pre-operative imaging in the operating room. To address this challenge, we present an accessible, interactive mobile augmented reality (AR) framework, HILMARTS, to enable accurate and efficient pre-operative virtual model-to-patient registration for AR-guided surgical navigation. Our system runs on a commercially available LiDAR-equipped iPad and supports a user-in-the-loop workflow through a two-stage coarse-to-fine registration process. First, the user performs a manual alignment using the AR view on the iPad. This initial maneuver is then refined through automatic point-cloud registration leveraging the LiDAR sensor. We further introduce a novel occupancy-grid-based Surface Coverage Score to provide real-time, actionable feedback to the operator on the geometric completeness of LiDAR data capture for reliable point-cloud-based alignment. In a phantom study with 16 participants, the system achieved a 3.31+/-1.26mm registration accuracy in ~4 min with a mean System Usability Scale (SUS) of 84.1. These findings highlight the system's accuracy, efficiency, robustness, and potential clinical usability, and could support its applicability to other AR-based surgical navigation tasks.

Closest papers

Nearest neighbours by meaning across the whole index.

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.69
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

cs.RO ·2026-10-08 ·Ehsan Nasiri, Yi Zheng, Michael A. Kokko, Xiaoyao Fan, William R. Warner +2 more
similarity 0.69
Abstract · Submitted to the ASME Journal of Mechanisms and Robotics; currently under review

This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

0.24

LARK: A Low-Cost, Accurate, Occlusion-Resilient, Kalman Filter-Assisted Tracking System for Image-Guided Surgery

cs.CV eess.IV ·2026-10-06 ·George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, Étienne Léger +1 more
similarity 0.66
Abstract · 24 pages, 15 figures, including appendices. Supplementary document included as an ancillary file. Supplementary video: https://youtu.be/ApZ8…

Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Commercial stereo infrared trackers are accurate but prone to occlusion and cost-prohibitive for many settings. This work presents LARK, a multi-camera optical tracking system using commodity RGB hardware and multi-view redundancy and fusion. We develop and evaluate two complete tracking methods: multi-view monocular pose fusion and multi-view triangulation. Both methods are assessed under varying occlusion levels using a precision-machined grid and an anatomical head phantom, and compared against a gold-standard stereo infrared system. With five cameras and adaptive Kalman filtering, LARK achieves median target registration errors of 0.64 mm for point localization with triangulation and 0.73 mm for trajectory tracking with pose fusion on the machined grid. Camera-subset experiments show graceful degradation in adaptive pose-fusion accuracy as fewer views remain available. With tracking hardware costing under $1,000 USD, LARK provides a low-cost platform for image-guided surgery research. Hardware designs and software are publicly available at https://nist.mni.mcgill.ca/software/ , and datasets at https://nist.mni.mcgill.ca/data/ .

0.25

ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration

cs.RO ·2026-10-07 ·Tiancheng Li, Yingyu Wang, Peter Walker, Liang Zhao, Shoudong Huang
similarity 0.64
Abstract · Preprint

Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263.

0.25

Harnessing Vision-Language Models for Perceptual Quality Assessment and Autonomous Content Adjustment in Augmented Reality

cs.CV ·2026-09-30 ·Elias Rotondo, Lin Duan, Yanming Xiu, Sangjun Eom, Conrad Li +1 more
publishedbenchmarkcode/data similarity 0.64
Abstract · To be published in VRST 2026. Main Manuscript: 12 pages, 5 figures; Supplemental Materials: 7 pages, 10 figures. The accompanying public rep…

Advancements in augmented reality (AR) continue to foster innovative solutions, facilitating novel methodologies within educational systems, healthcare delivery, and risk-mitigation protocols. However, optimizing for end-user immersion and comfort remains challenging, as AR head-mounted displays contend with constrained scene geometry, spatial jitter, and temporal instability. User studies are the standard AR evaluation method for visual quality, but their cost, diminishing scalability, and inflexibility pose bottlenecks during iterative application design. To address this problem, we present an automated framework for AR content evaluation and refinement, built on vision-language models (VLMs), to evaluate and predict the visual fidelity of AR scenes as perceived by users. First, we introduce RateAR, a benchmark of AR images and videos collected across diverse scenes and environmental conditions, with good-to-excellent reliability (ICC(2,5) >= .90) across perceptual factors, including object placement, scale, and shadow consistency. Subsequently, we evaluate eleven commercial VLMs on the crafted benchmark. Results support that VLM-based quality predictions strongly correlate with human subjective judgments, achieving Spearman's rank-order correlations of up to 0.8695. An ablation study further suggests that, compared to other prompting strategies, our contextual prompting yields better alignment with human ratings while balancing introduced complexity cues. Building on these findings, we construct an automated AR content adjustment system and conduct a 21-participant user study. More than 90% of participants found that the system improved placement and size coherence of virtual content.

0.56

RAUL: Reference-Assisted Ureteroscopy Localization for Skill Assessment

cs.CV ·2026-09-16 ·Fangjie Li, Mai Bui, Charan Mohan, Michael Miga, Matthieu Chabanas +2 more
hot direction similarity 0.64
Abstract

Objective: Incomplete navigation of anatomy during ureteroscopic kidney stone surgeries can contribute to repeat interventions. While skilled surgeons have lower reintervention rates, there are no objective metrics to quantify scope-navigation performance to evaluate when a trainee becomes skilled. This work aims to recover ureteroscope trajectories from endoscopic video and derive navigation metrics to quantify differences in skill. Methods: We propose RAUL, a reference-assisted reconstruction framework for recovering ureteroscope trajectories from ureteroscope videos only in phantoms. For each phantom, we use a slow, high-quality reference exploration video to generate a reference reconstruction. We localize subsequent exploration videos against this reference. We evaluate localization accuracy against electromagnetically tracked scope pose. We compute navigation metrics from phantom exploration trajectories to compare surgical residents across experience levels. Results: The proposed reference-assisted framework achieves a mean translation root mean square error of $0.5 \pm 0.1$ mm across 9 phantoms. Compared to standard Structure-from-Motion (SfM), the proposed pipeline increases frame-wise localization coverage from $50.5 \pm 14.9\%$ to $86.1 \pm 7.2\%$ of all video frames. The reconstructed trajectories revealed significant differences between high- and low-experience trainees in established navigation metrics. Conclusion: RAUL enables substantially more complete recovery of ureteroscope trajectories from videos compared to standard SfM pipelines, enabling trajectory-based skill assessment without additional tracking equipment. Significance: To the best of our knowledge, this is the first use of video-only recovery of ureteroscope trajectories without external tracking sensors for skill assessment, supporting scalable automated assessment of ureteroscopy navigation skill.

0.38

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.63
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

Dense Endoluminal Mapping and Localisation from Monocular Bronchoscopy

cs.CV ·2026-10-12 ·Salvatore Esposito, Matias Mattamala, Daniel Rebain, Liang Zhao, Kev Dhaliwal +2 more
similarity 0.62
Abstract

Bronchoscopy inserts a camera through the airways to diagnose endoluminal disease. Locating the camera along the airway usually requires additional equipment, such as an electromagnetic tracker and a preoperative CT scan. In this paper, we investigate the use of the monocular camera stream to localise the bronchoscope without requiring additional sensing. We introduce a monocular SLAM system that localises the tip of a bronchoscope and reconstructs the airway surface around it from RGB video alone. A Depth Anything 3 backbone, fine-tuned on over a million photorealistic airway renderings, returns metric per-pixel depth and is the system's only source of scale. DINOv3 features routed through a custom cross-attention matcher supply sub-pixel correspondences on mucosa where classical descriptors fail. Both enter a factor graph alongside a dense constraint from projective iterative closest point (ICP) registration against the system's own running reconstruction, so surface evidence stabilises the directions the visual factors leave weakly observable. On six airways rendered from patient CT scans, the system reaches 26.1 mm mean absolute trajectory error and 77.5% mean surface F-score. Its mean surface accuracy exceeds that of five recent monocular SLAM and feed-forward baselines. MASt3R-SLAM, which fits a free scale to the ground truth, has a lower mean trajectory error (22.0 mm). ORB-SLAM3 completes only two of the six airways, whereas our system completes all six and also reconstructs two ex vivo specimens.

0.16