CS Paper Radar

ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery

Jiawei Ge, Chunwoo Kim, Antony Goldenberg, Douglas McDonough, Justin Liao, Bo Ning, Sylvia Ladstaetter, Katya Van Anderlecht, Hao Ding, Laura Connolly, Ethan Kilmer, Francis Fan, Shouyue Hu, Tyler Salvador, Brendan Burkhart, Pit Henrich, Richard Cha, Tito Porras, Mathias Unberath, Kevin Cleary, Axel Krieger

cs.RO ·submitted 2026-11-11 07:23 UTC · v1
code/data

Abstract

Research on surgical autonomy needs open platforms that any laboratory can build, yet the most widely shared platform depends on donated clinical hardware, and open alternatives on industrial arms each lack part of the surgical chain. We present the Autonomous Robotic Translational System (ARTS), an open-source three-arm platform for autonomy research in minimally invasive surgery, built entirely from purchasable parts for about USD 137,000. Two UR5e arms hold wristed da Vinci X/Xi instruments, a UR5 arm holds a stereo endoscope with two FLIR cameras, the surgeon console provides haptic handles, footswitches and a stereo viewer, and a hardware stop independent of the software lets a supervisor freeze all three arms in place. The ROS 2 software pins every dependency, installs from the same scripts on bare metal or in containers, and records stereo images with hardware-measured timing. On the real arms, ARTS commands each arm at its controller's full rate (e.g., 500 Hz on the UR5e), the two cameras expose within 12 microseconds of each other, hand motion reaches the arm in 58 ms, and the endoscope image reaches the monitor in 68 ms. The ISO 9283 pose repeatability is 0.14-0.25 mm, comparable to a da Vinci Research Kit (dVRK) Classic arm on the same protocol, and an optical tracker measured a mean remote-center-of-motion error of 0.34-0.37 mm. Three expert and three novice operators performed the Fundamentals of Laparoscopic Surgery (FLS) peg transfer through a laparoscopic trainer box, and one of the experts sutured on a suture pad. The hardware designs, firmware and software are available at https://github.com/MRE-Lab-UMD/arts.

Comment
Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution

Closest papers

Nearest neighbours by meaning across the whole index.

DASH: A da Vinci Adapter for Serial-link and Humanoid Robots as an Accessible Platform for Surgical Robotics Research

cs.RO ·2026-10-05 ·Sara Wickenhiser, Junrong Zhou, Zekai Liang, Lizzie Peiros, Liu Shanglei +1 more
similarity 0.71
Abstract · 8 pages, 9 figures

Robotic minimally invasive surgery offers well-documented clinical benefits, but the cost and infrastructure requirements of purpose-built platforms limit access in rural and lower-resourced facilities. Recent work has teleoperated general-purpose robots for laparoscopic tasks and in vivo procedures, but relied on handheld instruments coupled through passive linkages rather than native robotic actuation. Instead, we adapt da Vinci Classic and Xi instruments onto general-purpose robots that can integrate in clinical workflows. We present DASH, a da Vinci Adapter for Serial-link and Humanoid platforms, consisting of two types of adapters that require no modification to the instruments themselves. Each adapter is compatible with many robotic platform load capacities, engages the instrument's native latch, and wirelessly identifies inserted tools to load instrument-specific kinematics and coupling matrices. Teleoperated experiments demonstrate the efficacy of DASH and its benefits for enabling research access to surgical robotic platforms.

0.45

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

cs.RO ·2026-09-22 ·Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei +3 more
published similarity 0.67
Abstract · 8 pages, 8 figures. Accepted to IROS 2026

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

0.41

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

cs.RO ·2026-10-08 ·Ehsan Nasiri, Yi Zheng, Michael A. Kokko, Xiaoyao Fan, William R. Warner +2 more
similarity 0.67
Abstract · Submitted to the ASME Journal of Mechanisms and Robotics; currently under review

This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

0.24

An Open-Source ROS 2 Framework for Shared Control in Surgical Teleoperation: Integrating the Haply Inverse3 with the da Vinci Research Kit

cs.RO eess.SY ·2026-11-19 ·Balint Varga, Sebastian Fritz, Gergely Kiss, Kristof Takacs, Peter Galambos
benchmarkcode/data similarity 0.66
Abstract

Surgical teleoperation deprives surgeons of touch, forcing visual inference of tissue forces; the commercial platforms now restoring force feedback remain closed, preventing open research on haptic shared control. This paper provides a system contribution: it presents an open-source, ROS 2-native framework that integrates the compact, three-degree-of-freedom (3-DOF) Haply Inverse3 haptic device with the da~Vinci Research Kit (dVRK). The framework includes a novel mapping strategy that combines 3-DOF translational device input with separately tracked VerseGrip orientation into 6-DOF patient-side manipulator commands. Two virtual-fixture-inspired guidance modes serve as reference implementations to evaluate the framework in a within-subjects user study on a teleoperated hot-wire benchmark task in simulation, and the architecture is further demonstrated on physical dVRK hardware. Relative to unassisted manual control, linear guidance significantly reduced both the number of wire contacts and the task completion time, whereas the progressive-stiffness guidance produced consistent but statistically non-significant trends in the same direction. Subjective ratings of workload, agency, and satisfaction showed favorable descriptive trends for the guidance modes. The results demonstrate the feasibility of haptic shared control with a compact device coupled to the dVRK and provide an openly available, reproducible platform for future research. They further suggest that simpler linear feedback may be more robust for inexperienced operators than more complex profiles.

0.25

Kinematic Interface for the Wild: Modular Bimanual Loco-Manipulation Capture from 360$^{\circ}$ Cameras Alone

cs.RO ·2026-09-19 ·Benjamin Yang, Weiying Wang, Shenggao Li, Keming Yan, Sasha Wilkinson +3 more
similarity 0.65
Abstract · 10 pages, 9 figures

A wrist-mounted camera for UMI-style data collection must do two jobs: record the manipulation and localize in the scene. Most handheld devices localize online from workspace-facing views crowded by hands and objects, or add dedicated tracking hardware. Room-scale bimanual capture therefore still tends to instrument the operator or the scene for accurate localization. We present KIWI (Kinematic Interface for the Wild), a capture kit whose only electronics are off-the-shelf cameras. Our core system splits the two jobs across the two lenses of a 360-degree camera. The rear lens faces the room and builds a shared metric map that registers both hands, and an optional head camera, in one frame without workspace co-visibility; the front lens records the manipulation, and offline IMU fusion bridges front-lens tracking loss. Through our quick-release plate, the camera module attaches to chopstick grippers, parallel-jaw grippers, hand-wrist mounts, or robot flanges. Across six bimanual recordings, combining the rear and front lenses failed to localize only 0.1% of query frames, whereas front-only bimanual feature alignment failed on 24.8% of frames and lost one recording entirely; against evaluation fiducials, localization error stayed within 4.5 mm. KIWI's recovered poses were sufficiently consistent for the four wrist streams alone to reconstruct the scene as a 3D Gaussian splat.

0.52

From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

cs.RO ·2026-09-22 ·Dongho Yee, Juahn Oh, Jinseok Lee, Jiyul Lee, Yechan Seo +8 more
code/data similarity 0.65
Abstract · Submitted to IEEE ICRA 2027. Project page & Dataset: https://rosota-research.github.io/instrument-mounted-demonstrations-in-vivo/

Most minimally invasive surgery is still performed with hand-held laparoscopic instruments, and the surgeon's instrument kinematics are lost when the operation ends; only the endoscope video is kept. This paper presents an end-to-end pipeline that captures this motion in the operating room and uses it to train a surgical robot policy, validated on live animals. We introduce a surgical instrument-state logger that mounts on the shaft of a standard laparoscopic instrument and recovers its pose and jaw state from an inertial sensor, a time-of-flight sensor and a Hall sensor, with no external camera or tracker. A data pipeline measures the latency of every sensor channel against a robot ground truth and aligns the channels before forming observation-action pairs. On these demonstrations we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed the appendectomy in three of the four animals. The results show that demonstrations recorded from a surgeon's own instruments are sufficient to train, select and deploy a bimanual surgical policy in vivo. The robot serves only as the timing reference for sensor calibration and as the executor, and collects no demonstrations. Both demonstration corpora are released to support future surgical robot learning research.

0.34

Design and Characterization of a Unified Continuum Robot Actuation Platform

cs.RO ·2026-10-14 ·Yunti Xu, Aedan Mangan, Miheer Potdar, Alex Lu, Tania K. Morimoto
similarity 0.65
Abstract

Continuum robots enable dexterous access to confined spaces in applications such as minimally invasive surgery and industrial inspection. However, their actuation systems are often custom-designed for specific robot architectures and tasks, limiting reuse across publications, institutions, and applications. This paper presents a unified actuation platform that decouples actuation hardware and software from continuum robot design. The platform provides modular actuation across continuum robot classes, scales to a large number of degrees of freedom (DOFs), and integrates with conventional serial manipulators for hybrid architectures. We validate the platform on an open-sourced surgical robotic system and experimentally characterize the actuation modules, achieving sub-millimeter translational accuracy and less than $5^\circ$ rotational error over ranges of $30$~mm and $180^\circ$, respectively. We further demonstrate the platform in two surgical use cases: teleoperation of a continuum camera in a constrained environment and bimanual manipulation using $2.53$~mm concentric-tube-robot-based forceps alongside a conventional wristed instrument. All hardware designs and ROS-based software are open-sourced to facilitate reuse and further research in continuum and surgical robotics.

0.31

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.65
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32