Abstract

Continuum robots enable dexterous access to confined spaces in applications such as minimally invasive surgery and industrial inspection. However, their actuation systems are often custom-designed for specific robot architectures and tasks, limiting reuse across publications, institutions, and applications. This paper presents a unified actuation platform that decouples actuation hardware and software from continuum robot design. The platform provides modular actuation across continuum robot classes, scales to a large number of degrees of freedom (DOFs), and integrates with conventional serial manipulators for hybrid architectures. We validate the platform on an open-sourced surgical robotic system and experimentally characterize the actuation modules, achieving sub-millimeter translational accuracy and less than $5^\circ$ rotational error over ranges of $30$~mm and $180^\circ$, respectively. We further demonstrate the platform in two surgical use cases: teleoperation of a continuum camera in a constrained environment and bimanual manipulation using $2.53$~mm concentric-tube-robot-based forceps alongside a conventional wristed instrument. All hardware designs and ROS-based software are open-sourced to facilitate reuse and further research in continuum and surgical robotics.

Closest papers

Nearest neighbours by meaning across the whole index.

Curvature by Design: A Support Structure for Continuum Robots

cs.RO ·2026-11-04 ·Justus Sagemüller, Harald Minde Hansen, Kristin Y. Pettersen
similarity 0.70
Abstract

Constant- and piecewise-constant-curvature models are widely used to simplify the kinematics of continuum robots, although the assumed curvature profiles are not necessarily inherent mechanical properties of the robot and may therefore be violated during operation. Rather than assuming a prescribed curvature profile in the kinematic model and estimating deviations from it, this paper presents a multi-segment scissor-based support structure that mechanically constrains a continuum robot to exhibit prescribed constant or spatially varying curvature profiles. The design uses Taylor approximations to enable an overconstrained multi-joint linkage to predictably distribute global bending among the small-angle movements of multiple flexures. The geometric coupling is realized using compliant flexure joints, enabling the support structure to be manufactured as a single piece. The structure is integrated with a tendon-actuated continuum robot with a flexible backbone. Experiments show that the structure makes the robot resistant to deformations other than the prescribed curvature, significantly enhancing shape precision compared to classical flexible-backbone designs. This constrains the robot from making S-shapes when external loads are applied in the opposite direction of the bending. By mechanically constraining the admissible deformation, the proposed structure reduces the number of independent shape variables that must be estimated.

0.11

Capstan-driven Continuum Surgical Robot: Design, Modeling, and Perception

cs.RO ·2026-08-13 ·Gang Zhang, Yufu Qiu, Junyan Yan, Wenhui Zeng, Wenlong Lu +1 more
similarity 0.69
Abstract

Shape and force sensing have long been critical bottlenecks in the development of compact capstan-driven continuum surgical robots, primarily due to the difficulty of obtaining cable tension information within the confined capstan assembly. To overcome these challenges, this paper presents an integrated design-modeling-sensing approach based on the concept of actuation-perception co-design. A compliant element is introduced into the motor mounting bracket of the drive system, enabling micro-deformation under the cable reaction force and thereby allowing real-time cable tension measurement without occupying the compact capstan space. To address the modeling complexity arising from unconventional joint configurations introduced by the spatial cable routing strategy, a parallel computation framework based on a multibody short-thick-beam model is proposed, which captures shear effects in short beam segments and synergistic multi-cable interactions while achieving real-time performance. Building on this framework, stable shape and force sensing is achieved by incorporating a proximal multi-axis force/torque sensor as an additional measurement anchor. Following this design-modeling-sensing framework, capstan-driven continuum surgical robots with single- and dual-segment configurations are developed. Experimental results validate the proposed framework in both single- and dual-segment continuum robots, demonstrating real-time tip pose estimation together with contact force and location perception. By enabling cable tension feedback without compromising the compact capstan architecture, the proposed framework makes integrated perception feasible for capstan-driven continuum surgical robots.

0.04

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.68
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

Controlling Continuum Robot Shape in Enclosed Space with Embedded Sensing using IMU and Actuator Feedback

cs.RO ·2026-10-28 ·Jiahe Wang, Sultan Haidar Ali, Eric Weissman, Jiefeng Sun
similarity 0.66
Abstract · 8 pages, 7 figures

Controlling continuum robots' shape to operate in confined, enclosed environments is challenging, since it cannot rely on external observation. Existing embedded shape sensing methods, although they can provide shape reconstruction, are insufficient to enable real-time shape control due to limitations in reconstruction accuracy, computational speed, and compatibility with shape-state representation. In this work, we present an embedded shape-sensing framework that uses readily available IMU and actuator feedback to reconstruct the continuum-robot shape with a neural network, providing accurate shape feedback at $400~\mathrm{Hz}$ for physical closed-loop control. We systematically investigate four key reconstruction design choices: shape-state representation, network architecture, training objective, and sensing inputs, through more than $5{,}000$ trained models on one- and three-segment continuum robots. The selected framework achieves global shape errors of $0.9\%L$ and $1.7\%L$ (of the robot length) for the one- and three-segment systems, respectively. In closed-loop control, one-segment tip tracking achieves a $6.1\%L$ error and three-segment shape control achieves a $2.3\%L$ global shape error, whereas IMU--PCC reconstruction using the same uncompensated measurements fails. Enclosed-space experiments further demonstrate operation without external observation. These results provide a practical framework for translating readily available embedded sensing into high-rate feedback for continuum robot closed-loop control.

0.34

DASH: A da Vinci Adapter for Serial-link and Humanoid Robots as an Accessible Platform for Surgical Robotics Research

cs.RO ·2026-10-05 ·Sara Wickenhiser, Junrong Zhou, Zekai Liang, Lizzie Peiros, Liu Shanglei +1 more
similarity 0.66
Abstract · 8 pages, 9 figures

Robotic minimally invasive surgery offers well-documented clinical benefits, but the cost and infrastructure requirements of purpose-built platforms limit access in rural and lower-resourced facilities. Recent work has teleoperated general-purpose robots for laparoscopic tasks and in vivo procedures, but relied on handheld instruments coupled through passive linkages rather than native robotic actuation. Instead, we adapt da Vinci Classic and Xi instruments onto general-purpose robots that can integrate in clinical workflows. We present DASH, a da Vinci Adapter for Serial-link and Humanoid platforms, consisting of two types of adapters that require no modification to the instruments themselves. Each adapter is compatible with many robotic platform load capacities, engages the instrument's native latch, and wirelessly identifies inserted tools to load instrument-specific kinematics and coupling matrices. Teleoperated experiments demonstrate the efficacy of DASH and its benefits for enabling research access to surgical robotic platforms.

0.20

ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery

cs.RO ·2026-11-11 ·Jiawei Ge, Chunwoo Kim, Antony Goldenberg, Douglas McDonough, Justin Liao +16 more
code/data similarity 0.65
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution

Research on surgical autonomy needs open platforms that any laboratory can build, yet the most widely shared platform depends on donated clinical hardware, and open alternatives on industrial arms each lack part of the surgical chain. We present the Autonomous Robotic Translational System (ARTS), an open-source three-arm platform for autonomy research in minimally invasive surgery, built entirely from purchasable parts for about USD 137,000. Two UR5e arms hold wristed da Vinci X/Xi instruments, a UR5 arm holds a stereo endoscope with two FLIR cameras, the surgeon console provides haptic handles, footswitches and a stereo viewer, and a hardware stop independent of the software lets a supervisor freeze all three arms in place. The ROS 2 software pins every dependency, installs from the same scripts on bare metal or in containers, and records stereo images with hardware-measured timing. On the real arms, ARTS commands each arm at its controller's full rate (e.g., 500 Hz on the UR5e), the two cameras expose within 12 microseconds of each other, hand motion reaches the arm in 58 ms, and the endoscope image reaches the monitor in 68 ms. The ISO 9283 pose repeatability is 0.14-0.25 mm, comparable to a da Vinci Research Kit (dVRK) Classic arm on the same protocol, and an optical tracker measured a mean remote-center-of-motion error of 0.34-0.37 mm. Three expert and three novice operators performed the Fundamentals of Laparoscopic Surgery (FLS) peg transfer through a laparoscopic trainer box, and one of the experts sutured on a suture pad. The hardware designs, firmware and software are available at https://github.com/MRE-Lab-UMD/arts.

0.44

Real-Time Whole-Body Safe Motion Generation for Multi-Segment Tendon-Driven Continuum Robots

cs.RO ·2026-09-22 ·Fangju Yang, Siyi Ma, Tonghao Guan, Tingcong Liu, Hang Yang +3 more
hot direction similarity 0.64
Abstract

Real-time motion generation for tendon-driven continuum robots requires accurate modeling of nonuniform bending and whole-body collision avoidance. This paper presents a unified actuation-space framework for planar multi-segment tendon-driven continuum robots. An energy-based variable-curvature model captures spatially varying tendon spacing and bending stiffness and provides analytical Jacobians for differential inverse kinematics and safety monitoring. A multipoint CBF-QP enforces backbone clearance under obstacle motion and actuation-velocity bounds, while its decision dimension depends only on the number of independently actuated segments. The model closely agrees with GVS references, with a maximum curvature error of $5.223 \times 10^{-2}\,\mathrm{m}^{-1}$. Over 100 MuJoCo trials, the proposed method achieves collision-free success rates of 96% and 100% in static and dynamic scenarios, respectively, compared with approximately 60% and 80% without CBF constraints. Hole-traversal tests further demonstrate safe motion in constrained environments. With 600 backbone monitoring points, the mean control-step time is 6.66 ms, demonstrating real-time whole-body safe motion generation.

0.29

Tendon-Driven Continuum Robot with Modular Stiffness and In-Situ Self Pose Estimation

cs.RO eess.SY ·2026-09-14 ·Guo Ning Sue, Zheng Cao, Junzhe Hu, Xiangyun Bu, David Quinn +3 more
similarity 0.64
Abstract

Continuum robots enable smooth shape morphing and safe interaction in confined environments. However, most existing systems are task-specific and depend on external sensing infrastructure, limiting their adaptability and real-world deployment. This paper presents a self-contained modular continuum robotic platform that combines mechanical reconfigurability with onboard pose estimation. The robot is constructed from interchangeable continuum joints with analytically precomputed stiffness, allowing rapid assembly and direct programming of the robot shape. Proprioceptive sensing is achieved using magnetic sensors and a modular learning-based framework, where a single model is trained per joint and reused across configurations. The system is experimentally validated in real world, demonstrating self-sensing capabilities and adaptation without external tracking.

0.34