Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan

cs.RO ·submitted 2026-08-31 04:08 UTC · v1

Abstract

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

Comment
34 pages, 9374 words

Closest papers

Nearest neighbours by meaning across the whole index.

A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

cs.RO ·2026-10-15 ·Sheng Cao, Shuxiang Guo, Yonggan Yan, Jian Guo, Chunying Li +6 more
similarity 0.68
Abstract

In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

0.19

Vision-Guided Closed-Loop Autonomous Navigation of Light-Driven Janus Microbots

cs.RO cond-mat.soft ·2026-10-15 ·Kanhu Charan Andia, Harsh Prashant Katole, Parth Nitinkumar Bhosale, Hemant Kumar, Dhruv Pratap Singh
similarity 0.63
Abstract · 26 pages, 7 Figures

Artificial microbots capable of precise and autonomous navigation could provide versatile platforms for microscale transport, manipulation, and task execution in complex environments. However, reliable navigation becomes increasingly challenging at the micrometre scale, particularly when the surrounding environment changes dynamically. Here, we develop a vision-guided closed-loop navigation framework for light-driven cube-shaped hematite/TiO2 Janus microbots with a characteristic size of approximately 3 μm. Real-time visual localization using a custom-trained YOLOv11 object-detection model is integrated with discretized waypoint-based magnetic steering to enable precise navigation along complex prescribed trajectories, with more than 90% of the measured trajectory deviations remaining below 6 μm across the tested path geometries. The framework further enables arbitrary user-defined free-hand trajectories and autonomous navigation through a physically confined maze. In dynamically changing environments, A* path planning enables real-time path replanning while avoiding multiple independently swimming 5 μm spherical Janus micromotors. Finally, the microbot selectively captures multiple cargo particles and autonomously transports and delivers them to a predefined location while simultaneously avoiding dynamic obstacles. These results establish an integrated platform combining programmable trajectory control, autonomous path planning, real-time environmental adaptation, and task execution within a single light-driven Janus microbot system.

0.19

A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention

cs.RO ·2026-10-14 ·Mingyu Zou, Shuxiang Guo, Sheng Cao, Pengcheng Li, Jian Guo +2 more
similarity 0.59
Abstract · 6 pages, 3 figures, submitted to IEEE journals

Robotic vascular intervention can reduce radiation exposure to physicians and improve manipulation stability, but effective guidance remains challenging because conventional fluoroscopic images provide limited spatial information. This paper developed a vascular intervention interactive system that connects a real robotic master controller with the SOFA(Simulation Open Framework Architecture) physical simulation platform and reused successful operation trajectories as visual guidance in physical phantom experiments. Experiments were conducted to validate the master-to-SOFA control loop and to compare three guidance conditions: no guidance, centerline guidance, and successful-trajectory guidance. The control validation results showed reliable command delivery under velocity-mode operation. In the physical phantom experiment, centerline guidance showed no obvious improvement over no guidance. In contrast, successful trajectory guidance provided a clear performance benefit. Compared with the no-guidance condition, it reduced task completion time, collision number, rollback number, and rotation number by approximately 66.8%, 34.3%, 55.6%, and 66.7%, respectively. These results indicate that successful trajectories obtained under instrument-vessel interaction can provide practical guidance cues, offering a simple and effective visual assistance strategy for robotic vascular intervention experiments.

0.32

Multimodal Image-based Robotic Assistance and Guidance Environment (MIRAGE): A Novel Unified Framework for Surgical Navigation and Visualization

cs.RO ·2026-10-08 ·Ehsan Nasiri, Yi Zheng, Michael A. Kokko, Xiaoyao Fan, William R. Warner +2 more
similarity 0.58
Abstract · Submitted to the ASME Journal of Mechanisms and Robotics; currently under review

This paper presents the computational architecture and quantitative preclinical evaluation of MIRAGE, a multimodal image-guided robotic surgery framework for real-time visualization and navigation. It integrates stereovision scene reconstruction, augmented-reality (AR) video overlay, quantified heads-up display (HUD) navigation, and intraoperative ultrasound within the da Vinci console's TilePro display (Intuitive Surgical). Additional modules include optical/electromagnetic tracker registration, stereo calibration, fiducial rigid registration with RMSE feedback, and 3D point-cloud reconstruction. Video I/O and rendering run in a C++ backend, while a Python GUI coordinates calibration, registration, reconstruction, visualization, and user interaction through an in-process zero-copy binding layer. The framework formalizes spatial transforms, module states, and synchronization of heterogeneous video and tracking streams. Preoperative calibration uses synchronized checkerboard image pairs and optimization, with estimated intrinsics, extrinsics, and rectification reused intraoperatively. MIRAGE was validated in phantom experiments across da Vinci S, Si, Xi, and SP platforms. Across clinically relevant working distances, mean 3D reprojection error was 0.6mm, with best 0.1mm RMSE at 100mm on Xi. Results support MIRAGE as a preclinical technical-validation platform for accurate, responsive, and extensible multimodal surgical guidance.

0.24

ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery

cs.RO ·2026-11-11 ·Jiawei Ge, Chunwoo Kim, Antony Goldenberg, Douglas McDonough, Justin Liao +16 more
code/data similarity 0.58
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution

Research on surgical autonomy needs open platforms that any laboratory can build, yet the most widely shared platform depends on donated clinical hardware, and open alternatives on industrial arms each lack part of the surgical chain. We present the Autonomous Robotic Translational System (ARTS), an open-source three-arm platform for autonomy research in minimally invasive surgery, built entirely from purchasable parts for about USD 137,000. Two UR5e arms hold wristed da Vinci X/Xi instruments, a UR5 arm holds a stereo endoscope with two FLIR cameras, the surgeon console provides haptic handles, footswitches and a stereo viewer, and a hardware stop independent of the software lets a supervisor freeze all three arms in place. The ROS 2 software pins every dependency, installs from the same scripts on bare metal or in containers, and records stereo images with hardware-measured timing. On the real arms, ARTS commands each arm at its controller's full rate (e.g., 500 Hz on the UR5e), the two cameras expose within 12 microseconds of each other, hand motion reaches the arm in 58 ms, and the endoscope image reaches the monitor in 68 ms. The ISO 9283 pose repeatability is 0.14-0.25 mm, comparable to a da Vinci Research Kit (dVRK) Classic arm on the same protocol, and an optical tracker measured a mean remote-center-of-motion error of 0.34-0.37 mm. Three expert and three novice operators performed the Fundamentals of Laparoscopic Surgery (FLS) peg transfer through a laparoscopic trainer box, and one of the experts sutured on a suture pad. The hardware designs, firmware and software are available at https://github.com/MRE-Lab-UMD/arts.

0.56

Simulating Vein Compressibility for Ultrasound-Guided Femoral Access: Speed, Accuracy, and Phantom Validation

cs.RO ·2026-11-09 ·Amit Manicka, Laurent Coulon, Darwin Ang, Michael Loushin, Timothy M. Kowalewski
similarity 0.58
Abstract · Submitted to the Journal of Medical Robotics Research (JMRR) for the International Symposium of Medical Robotics 2027 (ISMR 2027) 11 Pages (…

In ultrasound-guided femoral access, probe pressure deforms the tissue and changes the vascular anatomy a robot observes. A simulator must reproduce these mechanics fast enough for robotic interaction, yet the computational effort needed for a clinically meaningful signal like vein collapse before artery is unclear. We test the feasibility of a physics-based simulation in NVIDIA's Isaac Sim for Healthcare, with Stable Neo-Hookean tissue solved by Vertex Block Descent on one GPU. A simulation of a low-fidelity cylindrical benchtop phantom with known geometry and mechanical properties, pressed by a robot, predicted its artery within 5 percentage points at every depth. It matched the vein within 3 points through 11 mm of a 25.4 mm press and followed the collapse behavior of the low-fidelity physical phantom. Across element size, time step, and solver iterations, wall clock time per frame scaled linearly with solver work, but accuracy did not improve with more work. The chosen setting reduced solver time per frame by a factor of 976, from 29,700 ms to 30.4 ms, while remaining within 1.03 points of the finest reference setting. The physics solver alone took 30.4 ms per frame, while the full stack, including ultrasound and graphics rendering, took 56.4 ms per frame. Finally, when seeded with realistic literature-based mechanical properties, the digital leg model compressed the vein far more than the artery at every setting, reproducing the expected clinical signal of vein collapse before artery, which is used to distinguish them. In total, these results suggest that the NVIDIA Isaac Sim platform may be suitable for augmenting reinforcement learning training or online simulation for autonomous femoral access with ultrasound.

0.22

Interactive 3D Cutaway Visualization for Subsurface Target Localization in Robot-Assisted Surgery

cs.RO ·2026-11-02 ·Yuxin Chen, Wenxuan Wang, Wanwen Chen, Qi Zeng, Septimiu E. Salcudean
similarity 0.58
Abstract

Purpose: Blended augmented reality (AR) overlays can provide ambiguous depth cues in which subsurface anatomy floats above the tissue surface. We investigate whether an interactive 3D cutaway visualization can improve robot-assisted target localization. Methods: We propose Virtual Box, an interactive 3D cutaway interface that allows users to independently manipulate the viewing perspective to inspect subsurface targets. In a controlled, counterbalanced within-subject tissue phantom study, 15 engineering students used Virtual Box and a depth-enhanced blended AR overlay to position a da Vinci instrument at virtual targets in a water tank. We used registered 3D transrectal ultrasound to measure 3D localization error and depth error. We also collected completion time and subjective ratings. Results: Virtual Box reduced mean 3D error from 12.92 to 4.96 mm (61.6% reduction) and depth error from 9.48 to 2.07 mm (78.2% reduction; both p < 0.001). Spatial understanding, depth perception, and confidence ratings were higher (all unadjusted p < 0.001), but completion time increased from 21.64 to 32.58 s (p = 0.008). Overall workload did not differ significantly. Conclusion: Virtual Box improved localization accuracy and perceived spatial understanding in this controlled task, with additional completion time, supporting further evaluation for surgical navigation.

0.28

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.58
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42