CS Paper Radar

An Agentic AI Workflow for Liver Lesion Segmentation and Structured Radiology Reporting

Fatma Ahmed Mansour, Rahatara Ferdousi, Zyad Medhat Mahmoud Ashor, Manar Fathy Elshenawy, Ibrahim Shehaby, Salma Elmongi, S. Ahmed

cs.CV cs.LG ·submitted 2026-10-25 21:55 UTC · v3

Abstract

Despite advances in automated liver lesion segmentation, a gap remains between image-derived predictions and clinically interpretable radiology reports. Bridging this gap requires quantitative measurements that are both reproducible and traceable. We present an evidence-grounded agentic AI framework that connects liver and lesion segmentation with deterministic quantification and structured reporting. TotalSegmentator-based nnU-Net models delineate the liver, Couinaud segments, and lesions, while computational tools extract volumes, dimensions, counts, and anatomical locations. A large language model (LLM) organizes these measurements into a predefined reporting schema, with numerical consistency checks against source measurements. On 51 LiTS cases, the segmentation stage achieved a liver Dice score of 0.947, lesion sensitivity of 75.6%, and positive predictive value of 68.9%. Exploratory screening of 25,494 MERLIN reports identified 10,208 (40.0%) with liver-related abnormalities. By connecting quantitative imaging evidence with agentic report generation, this work takes a step toward human-centered medical AI that prioritizes traceability and clinical relevance.

Closest papers

Nearest neighbours by meaning across the whole index.

SMILE: A Structured Multi-Agent Clinical Reasoning for Liver Ultrasound Understanding

cs.CV cs.CLcs.LG ·2026-11-02 ·Haris Ghafoor, Minjee Seo, Seonaeng cho, Keungmo Yang, Jaejun Lee +1 more
publishedcode/data similarity 0.75
Abstract · Accepted at Winter Conference on Applications of Computer Vision (WACV) 2027

Automated liver ultrasound report generation improves the diagnosis of liver diseases by producing clinically structured descriptions of anatomical and disease-related findings. However, current generative vision-language models (VLMs) often rely on a single reasoning pathway that maps ultrasound appearance directly to textual descriptions. In addition to the inherent vision-language modality gap, this design is limited for liver ultrasound because disease interpretation is constrained by subtle visual evidence, heterogeneous disease patterns, and limited paired supervision. To address these limitations, we propose SMILE, a Structured Multi-agent clInicaL rEasoning framework that uses multiple complementary specialist agents to interpret ultrasound images and consolidates their outputs through a judge-guided consensus mechanism. Our approach employs three specialized agents: an image interpretation agent for morphological descriptions, a clinical-stage reasoning agent, and a visual question answering (VQA) agent for targeted queries. These agent responses are then aggregated and scrutinized by a judge VLM using a consensus filtering prompt to produce a unified, clinically coherent output. Across a public liver ultrasound dataset and an internal clinical dataset, SMILE consistently outperforms state-of-the-art VLMs, achieving up to 19.0\% improvement in ROUGE-1 and 18.8\% improvement in clinical F1-score, while reaching VQA F1-scores of 0.82 and 0.65 on public and internal datasets, respectively. These results demonstrate the potential of SMILE for data-scarce and limited-supervision clinical settings. Our models, datasets, and code are available \href{https://github.com/CMME-Lab/SMILE}{here}.

0.42

TIAgent: From Natural Language to Grounded Agentic Workflows for Computational Pathology

cs.AI q-bio.QMcs.CLcs.MA ·2026-09-30 ·Aakash Madhav Rao, Mark Eastwood, Danielle Belgrave, Fayyaz Minhas
benchmark similarity 0.72
Abstract

Computational pathology (CPath) analyses increasingly depend on multi-step computational workflows that require substantial programming expertise, limiting their accessibility to pathologists and other domain experts without extensive coding experience. Although large language models (LLMs) provide a promising natural-language interface for constructing such analyses, hallucinated operations and incorrect workflow specifications limit their reliability in scientific settings. We introduce Tissue Image Analysis Agent (TIAgent), an automated CPath workflow generation framework that, given a natural-language prompt specifying a complex analytical task together with an input dataset, automatically constructs a verifiable computational graph employing existing CPath operations. The resulting graph can be inspected and executed, enabling natural-language construction of complex CPath workflows for applications including automated biomarker discovery and tissue analysis. We demonstrate end-to-end workflow generation and execution and systematically benchmark 14 backbone LLMs across 90 unit tasks spanning 18 CPath operation types. The ability of each LLM to generate a complete and correct unit workflow is quantified using Unit Workflow Success (UWS). Performance varied substantially across backbone models, with Kimi-K2.7-Code achieving the highest UWS of 0.967 (95% CI: 0.907-0.989). Analysis of node and parameter correctness further revealed that selecting the appropriate computational operation and correctly configuring it represent distinct challenges for LLM-based workflow generation. TIAgent provides a foundation for making complex CPath workflow construction more accessible while enabling systematic evaluation of LLM-driven scientific workflow generation.

0.20

Can Agentic Systems Close the Gap in Radiology with Production AI Tools?

cs.AI cs.LG ·2026-11-06 ·Aubin Charley, Julien Khlaut, Charles Corbière, Pierre Manceron, Corentin Dancette +1 more
similarity 0.72
Abstract

Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements. Combining the two through agentic systems offers a route towards comprehensive radiology reporting, but published systems are tied to one modality or body part. We describe a radiology agentic framework that standardizes how an orchestrator calls modular tools to produce a structured report, and use it to measure what such a system can do with the tools from FDA-cleared radiology AI devices. Report generation is simulated on a large multi-modality report corpus, with the orchestrator given either a catalog of finding classes consolidated from the cleared devices, each available on the modalities it is cleared for, or an unlimited catalog in which any class can be requested, and planning either from the clinical indication or from the target report. Tool outputs are simulated from the reference report, so the comparison isolates tool availability and orchestration from tool error. With the cleared catalog and the indication alone, the orchestrator recovers under a third of the clinically actionable findings; recovery improves substantially with the unlimited catalog, and further when the plan is written from the target report. Attributing every missed finding to a cause shows that most are classes no cleared device offers for the study's modality, and that a third are classes or tools that were offered and not called. Adding the most frequently missing tools closes most of the gap to the unlimited catalog on held-out reports, whereas a smaller orchestrator with the unlimited catalog gives up the whole gain. Tool availability and effective orchestration are thus complementary constraints on comprehensive AI-assisted radiology reporting.

0.11

AMPLIFAI: A Multiphase CT Dataset for Benchmarking Clinical Reasoning in LI-RADS Assessment of Liver Lesions

cs.CV cs.LG ·2026-08-14 ·Pranav Kulkarni, Nikhil Shah, Amritansh Suryavanshi, Jana G. Delfino, James Tonascia +7 more
dataset similarity 0.72
Abstract · 15 pages, 6 figures, 3 tables

Hepatocellular carcinoma (HCC) is the third leading cause of cancer-related mortality worldwide, with early detection improving survival from <20% to >70%. The standardized Liver Imaging Reporting and Data System (LI-RADS) criteria provide an imaging-based diagnostic framework to evaluate liver lesions for HCC, serving as a foundation for automating HCC detection with artificial intelligence (AI). However, the lack of large, publicly available datasets with high-quality annotations has limited the development and evaluation of AI models for automated LI-RADS assessment. We introduce AMPLIFAI dataset, the first public dataset of 590 multiphase abdominal CT studies annotated with LI-RADS categories, lesion size, and voxel-level segmentations for three major LI-RADS features: arterial phase hyperenhancement, washout, and enhancing capsule. The dataset was curated and harmonized from four public datasets and augmented with expert annotations from five board-certified radiologists and one resident. Following the Datasheets for Datasets format, this paper details the dataset's composition, curation and harmonization process, and annotation workflow to support transparent, reproducible research in medical imaging AI.

0.10

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

cs.CV ·2026-10-15 ·Shrish Shrinath Vaidya, Gowthamaan Palani, Minmini Selvam, Gokulraja Srinivasaraja, Ganapathy Krishnamurthi
published similarity 0.71
Abstract · The paper has been accepted at ECCV BISCUIT Workshop, 2026

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.

0.22

ARISE: Adaptive Agentic Reasoning with Image-grounded Self-Evaluation for Interpretable IBD Assessment

cs.CV cs.AI ·2026-10-03 ·Pronoma Banerjee, Anuva Shah, Jason Wu, Md. Masudur Rahman, Sanjay Mohanty +2 more
similarity 0.70
Abstract

Inflammatory bowel disease (IBD) requires frequent imaging-based assessment, yet interpretation of modalities such as wireless capsule endoscopy (WCE) and intestinal ultrasound remains heavily dependent on specialist expertise. Vision-Language Models (VLMs) demonstrate significant potential in multimodal medical image analysis, but their clinical adoption is hindered by their insufficient domain-specific reasoning, susceptibility to hallucination, scarcity of high quality training data in fine-grained diagnostics and limited interpretability. We introduce ARISE (Adaptive Agentic Reasoning with Image-grounded Self-Evaluation), an autonomous planning framework that models few-shot medical image understanding as a sequential agentic workflow. ARISE structures agent execution into a transparent 5-stage workflow: hypothesis generation, image-grounded evidence summarization, evidence-conditioned refinement, symbolic verification, and final diagnosis. We apply ARISE to IBD assessment across two independent patient cohorts: wireless capsule endoscopy (WCE) images for Crohn's disease and B-mode ultrasound data for ulcerative colitis. ARISE consistently improves diagnostic performance over baseline VLMs while exposing where reasoning succeeds or fails, providing a more interpretable basis for clinical decision support and realistic deployment.

0.16

Towards Reliable AI-Based Histological Staining: A Systematic Study of Scaling and Uncertainty in Unpaired Generative Models

cs.CV ·2026-08-25 ·Qasim Siddiqui, Adrian Friebel, Maiju Myllys, Zaynab Hobloss, Daniela Gonzalez +2 more
benchmarkcode/data similarity 0.70
Abstract · 37th British Machine Vision Conference, November 2026, Lancaster, UK

Liver fibrosis, the principal predictor of long-term outcome in chronic liver disease, is staged from histological estimates of collagen content. Sirius Red (SR) provides the standard quantitative readout (collagen proportionate area, CPA) but is not acquired at every clinical centre and consumes tissue, time, and reagent cost beyond the routine Hematoxylin and eosin (H&E) stain. AI-based virtual staining can generate SR directly from H&E, yet systematic benchmarks of unsupervised models are scarce and their predictive uncertainty has not been quantified, even though visually plausible outputs may not faithfully reproduce the underlying tissue structure. We therefore benchmark six unsupervised image-to-image architectures (GAN-based and diffusion-based) across 54 scaling configurations on a newly released paired H&E to SR mouse liver dataset, the first open resource for this translation task. Each configuration is evaluated jointly on perceptual, distributional, and task-specific axes plus a blinded expert reader study; the best per family is then retrained as a deep ensemble, the first systematic comparison of epistemic uncertainty across unsupervised stain-to-stain architectures. Across families, perceptual quality, task-specific error, and ensemble agreement measure largely independent axes of model fitness: GAN-based methods cluster tightly on perceptual metrics yet differ substantially on task error and ensemble agreement, while the diffusion-based method (CycleDiffusion) is qualitatively different on all three. No single metric captures these differences, so reliable virtual staining requires reporting and selecting on all three jointly. The dataset, tiling pipeline, models, and evaluation code are released publicly.

0.24

MorphoOrgaAgent: A Foundation-Model-Based Multi-Agent System for Autonomous Organoid Analysis

cs.MA cs.CV ·2026-09-08 ·Hanyi Zhang, Maximilian Hoermann, Lion J. Gleiter, Yiling Xu, Bettina Katalin Budai +3 more
publishedbenchmarkcode/data similarity 0.68
Abstract · Accepted at the 2nd Agentic AI for Medicine Workshop, MICCAI 2026. 15 pages, 3 figures, 2 tables

Organoids are three-dimensional tissue models whose morphology provides important insights into tumor development, disease progression, and drug testing. Extracting these morphological features relies heavily on manual segmentation, which is time-consuming and labor-intensive. Furthermore, performing quantitative statistical analysis typically requires custom coding skills and a mathematical background, presenting a major barrier for experimental biologists. To address these challenges, we introduce MorphoOrgaAgent, a multi-agent framework that achieves zero-shot organoid segmentation, automated data analysis, and report generation based on natural language input. The framework consists mainly of three core components: a TaskUnderstandingAgent that identifies requested measurements and visualization types; a hybrid segmentation module that combines Cellpose-derived geometric prompts with text prompts to guide SAM3 for zero-shot organoid instance segmentation; and a ReportAgent that computes quantitative metrics and compiles them alongside generated visualizations into a structured report. We further introduce MorphoOrgaVQA, a benchmark designed for quantitative evaluation of agent systems in organoid morphology analysis. Experimental results demonstrate that MorphoOrgaAgent handles both explicit and descriptive user requests, produces measurements closely matching ground truth, and generates complete analysis reports without requiring manual programming. The complete source code and MorphoOrgaVQA benchmark are publicly available at https://github.com/peng-lab/MorphoOrgaAgent.

0.43