CS Paper Radar

Can Agentic Systems Close the Gap in Radiology with Production AI Tools?

Aubin Charley, Julien Khlaut, Charles Corbière, Pierre Manceron, Corentin Dancette, Léo Machado

cs.AI cs.LG ·submitted 2026-11-06 18:23 UTC · v1

Abstract

Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements. Combining the two through agentic systems offers a route towards comprehensive radiology reporting, but published systems are tied to one modality or body part. We describe a radiology agentic framework that standardizes how an orchestrator calls modular tools to produce a structured report, and use it to measure what such a system can do with the tools from FDA-cleared radiology AI devices. Report generation is simulated on a large multi-modality report corpus, with the orchestrator given either a catalog of finding classes consolidated from the cleared devices, each available on the modalities it is cleared for, or an unlimited catalog in which any class can be requested, and planning either from the clinical indication or from the target report. Tool outputs are simulated from the reference report, so the comparison isolates tool availability and orchestration from tool error. With the cleared catalog and the indication alone, the orchestrator recovers under a third of the clinically actionable findings; recovery improves substantially with the unlimited catalog, and further when the plan is written from the target report. Attributing every missed finding to a cause shows that most are classes no cleared device offers for the study's modality, and that a third are classes or tools that were offered and not called. Adding the most frequently missing tools closes most of the gap to the unlimited catalog on held-out reports, whereas a smaller orchestrator with the unlimited catalog gives up the whole gain. Tool availability and effective orchestration are thus complementary constraints on comprehensive AI-assisted radiology reporting.

Closest papers

Nearest neighbours by meaning across the whole index.

An Agentic AI Workflow for Liver Lesion Segmentation and Structured Radiology Reporting

cs.CV cs.LG ·2026-10-25 ·Fatma Ahmed Mansour, Rahatara Ferdousi, Zyad Medhat Mahmoud Ashor, Manar Fathy Elshenawy, Ibrahim Shehaby +2 more
similarity 0.72
Abstract

Despite advances in automated liver lesion segmentation, a gap remains between image-derived predictions and clinically interpretable radiology reports. Bridging this gap requires quantitative measurements that are both reproducible and traceable. We present an evidence-grounded agentic AI framework that connects liver and lesion segmentation with deterministic quantification and structured reporting. TotalSegmentator-based nnU-Net models delineate the liver, Couinaud segments, and lesions, while computational tools extract volumes, dimensions, counts, and anatomical locations. A large language model (LLM) organizes these measurements into a predefined reporting schema, with numerical consistency checks against source measurements. On 51 LiTS cases, the segmentation stage achieved a liver Dice score of 0.947, lesion sensitivity of 75.6%, and positive predictive value of 68.9%. Exploratory screening of 25,494 MERLIN reports identified 10,208 (40.0%) with liver-related abnormalities. By connecting quantitative imaging evidence with agentic report generation, this work takes a step toward human-centered medical AI that prioritizes traceability and clinical relevance.

0.23

MedPAO-VL: Interpretable and Protocol-Compliant Agent for Structured Radiology Report Generation

cs.CV ·2026-10-15 ·Shrish Shrinath Vaidya, Gowthamaan Palani, Minmini Selvam, Gokulraja Srinivasaraja, Ganapathy Krishnamurthi
published similarity 0.71
Abstract · The paper has been accepted at ECCV BISCUIT Workshop, 2026

Despite the remarkable generalization capabilities of Large Language Models, generating clinically accurate and structured radiology reports from medical images remains a significant challenge. Current end-to-end approaches function as black boxes, prone to factual hallucinations and generating ungrounded findings. This lack of reliability and failure to adhere to domain-specific structuring protocols, fundamentally limits their clinical utility. We present MedPAO-VL, a multimodal agent that shifts the paradigm from monolithic generation to explainable, iterative, protocol-compliant structured report generation. Unlike deterministic models, our plan-act-observe loop functions as a goal-oriented agent: it first perceives the Chest X-Ray through an explainable vision module designed to capture inherent diagnostic uncertainty, then iteratively refines the generated report by observing semantic discrepancies and self-correcting its generation for better alignment with visually detected clinical findings. Evaluation of our framework demonstrates that this agentic reasoning improves clinical correctness and completeness, achieving an expert-rated accuracy score of 3.5/5 and a structural score of 4.3/5. By prioritizing pathology specific explainability and iterative refinement over opaque end-to-end mapping, MedPAO-VL offers a transparent and clinically viable alternative for automated structured radiology report generation.

0.22

MedPAO-Assist: Edge-Deployable, Modality-Aware Agentic AI for Radiology Report Structuring

cs.AI ·2026-10-17 ·Shrish Shrinath Vaidya, Minmini Selvam, Ganapathy Krishnamurthi
published similarity 0.70
Abstract · The paper has been accepted at MICCAI Workshop Agentic AI for Medicine, 2026

The adoption of Large Language Models for radiology report structuring has been largely dominated by either proprietary cloud-based models or large open models requiring high-end GPUs for deployment, which is a critical bottleneck for clinical adoption in radiology workflows that demand data privacy and offline operation. To address this, we present MedPAO-Assist, an edge-deployable agentic framework that generates structured radiology reports directly from radiologist dictation and voice commands, requiring only $\approx3.3$ GB peak RAM and achieving an average end-to-end latency of $\approx31$ seconds on a standard laptop CPU through an asynchronous, multi-threaded execution pipeline. The system currently supports four major imaging modalities -- Chest X-ray, Chest CT, Abdomen CT, and Brain MRI. To our knowledge, it is among the earliest agentic systems to run its entire pipeline with a Small Language Model (SLM) in the 0.6B-parameter range. This multi-agent architecture, built around an Extract-Ground-Generate paradigm, performs concept extraction, SNOMED-CT grounding, and structured report generation, followed by a speech-driven human-in-the-loop correction phase, together forming a fully "no-touch" reporting workflow that requires no keyboard input, external API calls, or internet connectivity. We evaluate each pipeline stage individually -- concept extraction, ontology grounding, and concept categorization and report hardware profiling results demonstrating the system's feasibility for real-time, CPU-only clinical deployment.

0.24

Reliability Stress Tests and Decision-Time Routing for Chest X-ray Vision-Language Models

eess.IV cs.CV ·2026-10-01 ·Xinye Yang, Zhusi Zhong, Scott Collins, Grayson Baird, Xuyu Wang +1 more
publishedbenchmarkcode/data similarity 0.68
Abstract · 6 pages, 4 figures, 5 tables. Accepted version of a workshop paper presented orally at the 2026 IEEE/ACM Conference on Connected Health: App…

Medical vision-language model (VLM) evaluation is sensitive to workflow design, prompting strategy, and benchmark construction, yet most studies treat these factors in isolation. We introduce a reliability stress test for chest X-ray interpretation built on two balanced datasets (a private report-backed set and a curated MIMIC subset). Three medical VLMs (CheXagent, MedGemma-4B, and MedGemma-27B) are evaluated across three prompt styles and two workflows (single-VLM and multi-agent), producing 36 configurations. We show that exact-match accuracy alone can overstate the effectiveness of conservative models that default to "Normal" predictions. Diagnostic reliability also depends heavily on model family and scale: multi-agent reasoning helps some configurations but hurts others. Building on these observations, we propose a decision-time routing framework that selectively escalates to multi-agent inference only when beneficial, improving the cost-quality trade-off over fixed workflows. Our results highlight the need for evaluation protocols that jointly consider prompt sensitivity, failure-mode diversity, and workflow choice before clinical deployment.

0.70

Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation

cs.CL ·2026-08-18 ·Iryna Hartsock, Cesar Lam, Christopher Otteni, Aliya Qayyum, Robert Gatenby +2 more
similarity 0.68
Abstract · 14 pages, 2 figures, 4 tables

Purpose: To develop and evaluate a locally deployed multi-agent AI system for radiology report structuring and quality assurance. Materials and Methods: This retrospective study included 638 radiology reports from CT examinations of the chest, abdomen, and pelvis dictated by 15 board-certified radiologists in 2023 and 2024. A multi-agent AI pipeline was developed to perform report structuring and quality assurance (QA). The system structured the report into standardized anatomical sections at the sentence level using regex rules and local large language models. It also detected mismatches between the Findings and Impression sections, or within sections; gender-anatomy conflicts; and undocumented communication of critical findings. Two board-certified radiologists independently evaluated a 45-report subset. Results: The multi-agent system structured the Findings sections of all reports (22,270 sentences) into a predefined anatomical format while retaining the original report content. The system flagged 90 (14.1%) reports, most commonly for section mismatches (80 reports, 12.5%). In the radiologist evaluation, both reviewers agreed that 31 (69%) were correctly restructured, 2 reports (4%) were incorrectly restructured, and disagreed on the remaining 12 reports (27%). Both reviewers agreed that no clinically important information was omitted and no fabricated content was introduced. Overall QA performance was rated as "excellent" or "good" in 84% of the evaluated reports, with the remaining reports rated as "fair". Conclusion: A locally deployed multi-agent AI system combined radiology report structuring and quality assurance within a single workflow. The system demonstrated favorable performance in radiologist evaluation. Such systems may support standardization of reporting and quality assurance in radiology practice.

0.37

Research with AI Agents: How Agentic Systems Are Changing Scientific Work

cs.CY ·2026-09-25 ·Johannes Lotz, Markus Wenzel
similarity 0.67
Abstract · 6 pages, 1 figure. English translation followed by the original German version. Submitted to Die Pathologie (Springer Medizin)

Background. Agentic AI systems independently decompose tasks such as literature search, data analysis, and programming into subtasks, search the web, access databases, and execute code. This allows them to perform digital research tasks at high speed. Objectives. Under what conditions does the use of agentic systems produce reliable efficiency gains, and which tasks remain with researchers? Materials and methods. Summary of current studies on literature searches, data analysis, software development, and clinical decision support. Results. For digital activities, work shifts from execution to steering and review. Efficiency gains are greatest when expected behavior can be formalized in advance and tested automatically. In complex agentic systems, recorded sequences of reasoning steps and tool calls can quickly become too extensive for human review. Furthermore, explanations generated by the model do not reliably reflect how an output was produced. One possible step toward more reliable systems is the validation of individual components. The limited reviewability extends beyond research itself; the review of scientific articles and grant proposals is also reaching capacity limits. In pathology, curated and annotated data, researchers' own analytical skills, and institutional exchange of experience are becoming increasingly important. Conclusions. Researchers remain responsible for their results. They must determine what to delegate and how to review the results. The importance of a research question to patients, the field, and society cannot be fully assessed using formalized criteria and remains a matter of expert judgment. Agentic systems can free up time for this.

0.09

MedicalHarness: A Controlled Evaluation of LLMs and Agent Harnesses on Medical Tasks

cs.CL ·2026-10-05 ·Ziqing Wang, Lili Zhao, Kaize Ding
benchmarkcode/data similarity 0.67
Abstract

LLM agents are increasingly built for medical work and scored on clinical benchmarks. Each such score, however, comes from a model running inside an agent harness, the system that controls the loop between the model and its environment. An agent's score is therefore a property of a model--harness pair. For medical agents, how much outcomes change with the harness has rarely been measured. Measuring this change, and explaining it, raises two challenges. First, a harness comparison must change nothing but the harness and be repeated across models and kinds of task. Second, comparing whole harnesses leaves their mechanisms bundled together, so it cannot show when an individual mechanism helps. To address these challenges, we present MedicalHarness, a controlled study of models and agent harnesses on medical tasks. We first build MedicalHarnessBench to evaluate agents on $107$ tasks across four domains that each test a different harness capability. Using this benchmark, we run five open-weight models under five agent harnesses, changing only the harness within a comparison, and analyze both outcomes and execution traces. To study individual mechanisms, we build MH-Lab, a controlled harness that switches off context management, planning or tool exposure one at a time within a shared execution loop. We find that the harness and its interaction with the model account for about a quarter of the outcome variance, and that no single harness is best across models and tasks. Code and data are available at https://github.com/REAL-Lab-NU/MedicalHarness.

0.37

MMedAgent-Plus: Scaling Multimodal Medical Agents across Modalities, Tasks and Workflows

cs.CL cs.AI ·2026-10-19 ·Ruoxin Wang, Yuanting Pan, Binxu Li, Ruiyang Ji, Yaqian Chen +11 more
similarity 0.67
Abstract · 66 pages, 28 figures

Medical workflows often require multiple interdependent analyses, but existing specialist and generalist AI models are not designed to coordinate them. We introduce MMedAgent-Plus, a multimodal medical tool-use agent that combines a vision-language planner with 18 leading specialist models spanning 12 tasks and 8 modalities. Through a unified tool interface, the planner selects specialists, executes them in sequence, and synthesizes responses grounded in their outputs. The planner is instruction-tuned on 208,928 samples from 32 public medical benchmarks, covering single- and multi-tool interactions across single and multiple rounds. We separately evaluate tool orchestration, response synthesis, and end-to-end execution on held-out samples. MMedAgent-Plus achieves tool-call accuracies of 91.0%, 98.1%, and 80.7% in single-tool multi-round, multi-tool multi-round, and multi-tool single-round settings, respectively. Given correct tool outputs, MMedAgent-Plus achieves scores of 14.4-14.8 out of 15 for faithfulness, completeness, and conciseness across 600 evaluation samples. In end-to-end execution without pre-supplied tool outputs, MMedAgent-Plus correctly invokes the required specialist in 90.6% of 350 evaluation cases spanning seven tasks. Its final-answer accuracy reaches 0.98, matching the dedicated leading specialist and exceeding the strongest baseline (0.28).

0.38